HomeMy WebLinkAbout2570 - Plans, Sections, ElevationsPLAN) I, A REF NO 'TuENT 25 /7 O ALL WORK TO BE CARRIED OUT IN ACCORDANCE WITH STANDARD BUILDING REGULATIOR FOUNDATIONS Cavity wall foundations to be 900mm x400mm 21N/sq mm taken down to a firm load bearing sub -soil Internal foundations to be 400mm x300mm as above Min cover on foundation to be 450mm . In the event of poor ground conditions the contractor should consult with the engineer SUN ROOM 011 ROOF Roof finish to be as indicated on elevations on 50mm x25mm s/w treated timber battens on one on 50mm x25mm s/w treated timber battens on one Rafters 125mm x50mm at 450mm centres Purlins to be 250 mm x100mm and supported on to structural walls as often as possible Ceiling joist to be 125mm x50mm at 450mm centres with hangers and binders at mid span Ridgen board 225mm x25mm Hangers 125mm x50mm Binders 125mm x50mm Wallplates 112.5mm 75mm strapped to walls at 1.5m centres Soffiitt and fascia to be of P V C with a 25mm continuos ventilation strip STABILITY Where timbers run L parallel to walls , laterral stability to be provided at floor ,ceilings and roof levels by means of 30mm x5mm mild steel galvanised straps at1.5m centres Straps to stretch over 3 no joist or rafters 6 It should be noted that this is a Planning drawing only and therefore is limited in its capacity to convey the total information, details and specification to complete the work.If any situation arises which may cause a contravention of the Building Regulations then the architect should be consulted DINER LIVING ROOM BEDROOM BEDROOM KITCHEN ENTRANCE HALL PORCH 6 3 6 O J GROUND FLOOR PLANS 0 BATHROOM FIRST FLOOR PLAN WALLS Cavity walls to be of 2 no 100mm thick dense blockwork with 55mm Celotex double R cavity insulation fixed to outer face of inner skin Cavity wall ties to be positioned at 750mm horiz and 450mm vert and care should be taken to make sure all ties are free from droppings. PLASTERING AND STUD WALLS Internal walls to be plastered with 12.5mm carlite bonding and 3mm hardwall plaster skim finish.Metal edge trims to be used on all comers or edges.Ground floor ceilings to be sheeted with s a 60 Q 12.5mm plasterboard and 5mm skim finish. FINISHED FLOOR SLAB 150 mm Stud walls to be constructed with 75mmx 50mm softwood vertical frames at powerfloated concrete floor on 400mm centres with noggins at 1200mm centres. 40mm rigid Urethane Foam insulation on 1000 gauge polythene dpm, with radon sump and vent.50mm blinding TOILET on minimium 250 mm compacted hadcore. LOBBYUTILITY ROOM HOT PRESS IN SITTING ROOM RADON PREVENTION: To comply with most recent Regulation a radon sump should be provided and depending on radon levels in the area a radon screen may be needed at subfloor level . DAMP PROOF COURSE Provide Hyload D P C at reveals to all openings and at floor level a min of 150mm above ground level and overlapping floor D P C BEDROOM 1 WALK IN WARDROBE ENSUITE BEDROOM TIMBER FLOORS All first floors to be of 19mm T & G flooring Grade plywood on 50mm x 25mm battens fixed to P C slabs to Manufacturers instructions. In bathrooms or ensuites Marine Plywood to be used. GREY DASH s� Cad i � n IBA►] REAR ELEVATION Internal Doors To be six panel Regency pine doors on softwood frame with red deal nosed architraving.Good quaility Mortise lockset to all doors and one and a half pair of solid brass washered hinges. SIDE ELEVATION FRONT ELEVATION CHIMNEY FLUES Flue liners to be fire clay ,rebated and socketed complying with B S 1181 Chimny to have horizontal lead tray/ dpc , soakers and cover flashings. QUOINS SECTION AA VENTILATION Provide mechanical vetilation to all ensuites bathrooms,and toilet areas that have an extraction of 15 litres per second. Kitchen to have extraction of 30 litres per second. SELECTED BLACK SLATES Co�NCIL +a e ®�'���' ESCAPE WINDOWS Alternate means of escape to be provided to each habitable room.They should have a min clear opening height of 850mm and width of 500mm and lower edge of window to be between 800mm and 1100mm above floor SIDE ELEVATION FLOOR AREA OF FIRST FLOOR EQUALS 100.40 SQ METRES FLOOR AREA OF GROUND FLOOR EQUALS 117 76 SQ METRE TOTAL FLOOR AREA EQUALS 228.16 SQ METRES J0O TITLE. DWELLING HOUSE IL------- --------- --- — rGLIENT — — — — — — — — — — — — — — — — — — — — — FIONA LYNSKEY I I -------------------------- - — — — — — — i5GALE5 — — — — — — — — — — — — — 1/100/ 1/50 ---------------- — — — — — — I AGENT; Nlall Mc KEnna, L---------- -------------------------- J DYUVY�E5C01 I DATE 17/9/2023 5co sl own, L------------------------- ----------------------- -- Go. Mona9 han, I I DW9, No 85/23 �EI/04759 I I q