HomeMy WebLinkAbout2581 - Plans, Sections, ElevationsALL WORK TO BE CARRIED OUT IN ACCORDANCE WITH STANDARD BUILDING REGULATION
It should be noted that this is a Planning drawing only and
therefore is limited in its capacity to convey the total
information, details and specification to complete the
work.lf any situation arises which may cause a
contravention of the Building Regulations then the
architect should be consulted
WALLS Cavity walls to be of 2 no 100mm thick dense blockwork
with 35mm Celotex double R cavity insulation fixed to outer
face of inner skin Cavity wall ties to be positioned at
750mm horiz and 450mm vert and care should be taken to make
sure all ties are free from droppings.
DISABLED ENTRANCE _
SMOKE ALARM
DAMP PROOF COURSE Provide Hyload D P C
at reveals to all openings and at
floor level a min of 150mm above ground
level and overlapping floor D P C
21:�75 2230 23gci I800 2320 1010 qqC 1210 de 11(50
DINER
LINE OF FOOTPRINT
FOR HOUSE GRANTED
PERMISSION
GROUND FLOOR AREA EQUALS
EQUALS 137.96 SQ METRES
FIRST FLOOR AREA EQUALS
122.91 SQUARE METRES
TOTAL FLOOR AREA EQUALS
260.87 SQUARE METRES
PUMPED CAVITY WALL INSULATION
BY SPECIALIST
LIVING
ROOM
ENTRANCE
HALL
KITCHEN
RC
UTILITY
SITTING
ROOM
DENOTES ADDDITIONAL FOOTPRINT TO THAT PREVIOSLY GRANTED PERMISSION 17/850 SOFFIT AND FASCIA BY SPECIALIST
ro3g7 I. 1200 I. 2720 I. 1200 4580 I.
750 1020 000 1020 1785 1020 1785 1 02 0 ro00 1 02 0 11 L, 7O10 11
FOUNDATIONS Cavity wall
foundations to be 900mm x400mm
21 N/sq mm taken down to a firm
load bearing sub -soil Internal
foundations to be 6600mm x300mm as
Min cover on foundation to
In the event of poor ground
ELEVATION conditions the contractor should
consult with the engineer
PLASTERING AND STUD WALLS Internal walls to
be plastered with 12.5mm carlite bonding and
3mm hardwall plaster skim finish.Metal edge
trims to be used on all corners or
edges.Ground floor ceilings to be sheeted
with 12.5mm plasterboard and 5mm skim finish.
Stud walls to be constructed with 75mmx 50mm
softwood vertical frames at 400mm centres
with noggins at 1200mm centres.
VENTILATION Provide mechanical ventilation to all ensuites
bathrooms,and toilet areas that have an extraction of 15 litres/sec
Kitchen to have extraction of 30 litres per second.
CHIMNEY FLUES Flue liners to be fire clay ,rebated and
socketed complying with B S 1181 Chimny to have
horizontal lead tray/ dpc , soakers and cover
flashings.
REAR ELEVATION
j
)WS BY
kLIST
ESCAPE WINDOWS Alternate
means of escape to be
provided to each habitable
room.They should have a min
clear opening height of 850mm
and width of 500mm and lower
edge of window to be between
800mm and 1100mm above floor
SIDE ELE
---------- ------------------------ ---------------------------
C�IENT
EOGHAN TRECOUNCIL
I-111%al X
L______________________________________________
r---------------------------------------------i
AGENT:
�SCALES 1/10091/50
---- - ------- ----------
- ----J N1a11 Mc Kenna,
-- - -
---- ------ ---- ------------------------- o r u m d e s c o,
;DATE 12/11/2017 Scotstown,
_______________________________ _-__________ Co. M o n a g h a n
0wg. No 76/2107 tp1/nA7Pa�1Q