HomeMy WebLinkAbout2581 - Plans, Sections, ElevationsALL WORK TO BE CARRIED OUT IN ACCORDANCE WITH STANDARD BUILDING REGULATION It should be noted that this is a Planning drawing only and therefore is limited in its capacity to convey the total information, details and specification to complete the work.lf any situation arises which may cause a contravention of the Building Regulations then the architect should be consulted WALLS Cavity walls to be of 2 no 100mm thick dense blockwork with 35mm Celotex double R cavity insulation fixed to outer face of inner skin Cavity wall ties to be positioned at 750mm horiz and 450mm vert and care should be taken to make sure all ties are free from droppings. DISABLED ENTRANCE _ SMOKE ALARM DAMP PROOF COURSE Provide Hyload D P C at reveals to all openings and at floor level a min of 150mm above ground level and overlapping floor D P C 21:�75 2230 23gci I800 2320 1010 qqC 1210 de 11(50 DINER LINE OF FOOTPRINT FOR HOUSE GRANTED PERMISSION GROUND FLOOR AREA EQUALS EQUALS 137.96 SQ METRES FIRST FLOOR AREA EQUALS 122.91 SQUARE METRES TOTAL FLOOR AREA EQUALS 260.87 SQUARE METRES PUMPED CAVITY WALL INSULATION BY SPECIALIST LIVING ROOM ENTRANCE HALL KITCHEN RC UTILITY SITTING ROOM DENOTES ADDDITIONAL FOOTPRINT TO THAT PREVIOSLY GRANTED PERMISSION 17/850 SOFFIT AND FASCIA BY SPECIALIST ro3g7 I. 1200 I. 2720 I. 1200 4580 I. 750 1020 000 1020 1785 1020 1785 1 02 0 ro00 1 02 0 11 L, 7O10 11 FOUNDATIONS Cavity wall foundations to be 900mm x400mm 21 N/sq mm taken down to a firm load bearing sub -soil Internal foundations to be 6600mm x300mm as Min cover on foundation to In the event of poor ground ELEVATION conditions the contractor should consult with the engineer PLASTERING AND STUD WALLS Internal walls to be plastered with 12.5mm carlite bonding and 3mm hardwall plaster skim finish.Metal edge trims to be used on all corners or edges.Ground floor ceilings to be sheeted with 12.5mm plasterboard and 5mm skim finish. Stud walls to be constructed with 75mmx 50mm softwood vertical frames at 400mm centres with noggins at 1200mm centres. VENTILATION Provide mechanical ventilation to all ensuites bathrooms,and toilet areas that have an extraction of 15 litres/sec Kitchen to have extraction of 30 litres per second. CHIMNEY FLUES Flue liners to be fire clay ,rebated and socketed complying with B S 1181 Chimny to have horizontal lead tray/ dpc , soakers and cover flashings. REAR ELEVATION j )WS BY kLIST ESCAPE WINDOWS Alternate means of escape to be provided to each habitable room.They should have a min clear opening height of 850mm and width of 500mm and lower edge of window to be between 800mm and 1100mm above floor SIDE ELE ---------- ------------------------ --------------------------- C�IENT EOGHAN TRECOUNCIL I-111%al X L______________________________________________ r---------------------------------------------i AGENT: �SCALES 1/10091/50 ---- - ------- ---------- - ----J N1a11 Mc Kenna, -- - - ---- ------ ---- ------------------------- o r u m d e s c o, ;DATE 12/11/2017 Scotstown, _______________________________ _-__________ Co. M o n a g h a n 0wg. No 76/2107 tp1/nA7Pa�1Q