Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2560502 - Drainage Network Drawings
STOPSTOPSTOPEMBANKEMENTSSLOPE 1:2EMBANKEMENTSSLOPE 2:378.0073.2979.00EX 81.38580.0080.0077.5078.0178.0077.9180.0076.0070.2571.0171.7772.5373.2974.0574.8174.5776.3377.0977.6371.2572.2573.2574.2575.2576.2577.2577.5877.9178.2578.4578.6578.4578.2578.0077.7577.5077.2577.0077.0077.2577.5077.7578.0077.0078.0077.75EX 72.00EX 72.0078.2178.3178.41EX 63.0078.0578.3578.6578.9578.4579.00EX 81.385NO.1TYPE AFFL: 78.15NO.4TYPE AFFL: 78.60NO.3TYPE AFFL: 78.60NO.2TYPE AFFL: 78.60NO.6TYPE AFFL: 77.90NO.5TYPE AFFL: 78.45NO.8TYPE AFFL: 77.30NO.7TYPE AFFL: 77.75NO.24TYPE D1FFL: 78.30NO.28TYPE CFFL: 78.30NO.23TYPE B2FFL: 78.75NO.22TYPE B1FFL: 78.75NO.25TYPE D1FFL: 77.30NO.27TYPE B1FFL: 77.75NO.29TYPE B3FFL: 78.30NO.21TYPE B1FFL: 79.20NO.30TYPE D2FFL: 78.30NO.20TYPE D2FFL: 79.20NO.26TYPE B2FFL: 77.75NO.15TYPE D1FFL: 78.30NO.12TYPE CFFL: 78.60NO.16TYPE B2FFL: 78.75NO.17TYPE B1FFL: 78.75NO.9TYPE D2FFL: 78.30NO.11TYPE B1FFL: 78.30NO.13TYPE B3FFL: 78.60NO.18TYPE B1FFL: 79.20NO.14TYPE D2FFL: 78.60NO.19TYPE D2FFL: 79.20NO.10TYPE B2FFL: 78.30F1MH size: 1200mmCL: 78.043mIL: 76.643mF2MH size: 1200mmCL: 77.024mIL: 75.661mF3MH size: 1200mmCL: 77.000mIL: 75.578mF4MH size: 1200mmCL: 78.232mIL: 74.713mF5MH size: 1200mmCL: 77.593mIL: 74.104mF6MH size: 1200mmCL: 77.483mIL: 74.076mF7MH size: 1200mmCL: 76.431mIL: 73.421mF9MH size: 1200mmCL: 71.030mIL: 67.934mF10MH size: 1200mmCL: 69.672mIL: 67.007mF_ExistMH size: 1200mmCL: 62.950mIL: 61.509mF14MH size: 1200mmCL: 79.023mIL: 77.673mF15MH size: 1200mmCL: 78.407mIL: 77.057mØ150mm Slope 1:17.2 Ø150mmSlope 1:45.0 Ø150mmSlope 1:70.3Ø150mmSlope 1:70.0Ø225mmSlope 1:100.0Ø225 m m Slope 1 : 1 0 0 . 8 Ø225mmSlope 1 :22 .0 Ø2 2 5 m m Slo p e 1 : 2 2 . 0 Ø225mm Slope 1:22.0 Ø225mmSlope 1:22.0Ø150mmSlope 1:16.5F8MH size: 1200mmCL: 73.727mIL: 70.213mØ22 5 m m Slo p e 1 : 2 2 . 0 F13MH size: 1200mmCL: 63.307mIL: 61.771mØ 2 2 5 m m Sl o p e 1 : 2 2 . 0F11MH size: 1200mmCL: 67.773mIL: 65.079mØ225mmSlope 1:22.0F12MH size: 1200mmCL: 65.668mIL: 62.672mØ225mmSlope 1:22.0FOUL SEWERKEYEXISTING SEWER© COPYRIGHT: These drawings are the copyright of CS Pringle Ltd. and they must not be reproduced without consent from this company.P|+353 42 9746492E|info@cspringle.comwww.cspringle.comFILE LOCATION: Geda Emyvale 6532\6. Planning\Drawings\SITEDATE:SCALES:REVISION:DRAWN BY:CHECKED BY:DRAWING NUMBER:ARCHITECTS | ENGINEERS | BUILDING SURVEYORSLOCATIONSTAGECLIENTHOUSING DEVELOPMENT EMYVALECSPringle■PLANNINGGEDA CONSTRUCTION CO. LTD.MARKET HOUSE LANE, EMYVALE, CO. MONAGHANMain St, Castleblayney,Co. Monaghan,A75 YR996532-CSP-P-GW/RMKOR006Nov 20251:500 @A1-FOUL SEWER PLANNORTHRECEIVED: 12/12/2025 Link NameSection Type ØSlope (1:X)Cover LevelInvert LevelLengthDatum 61.00064.60068.20071.80075.40079.000F178.043 1.000150mm45.076.64375.66144.189F277.024 1.001150mm70.375.66175.5785.832F377.000 1.002150mm70.075.578 74.78855.321F478.232 1.003225mm100.074.713 74.10460.894F577.593 1.004225mm100.874.10474.0762.823F677.483 1.005225mm22.074.076 73.42114.403F776.431 1.006225mm22.073.421 72.20726.711F873.727 1.007225mm22.070.213 69.00026.696F971.030 1.008225mm22.067.934 67.00720.396F1069.672 1.009225mm22.067.007 66.27916.024F1167.773 1.010225mm22.065.079 64.17219.959F1265.668 1.011225mm22.062.672 61.77119.818F1363.307 1.012225mm22.061.771 61.5095.770F_Exist62.950Bedding/BackFill14mm to 5mm graded aggregate or 10mm single sized aggregateSTOPSTOPSTOPNO.1TYPE AFFL: 78.15NO.4TYPE AFFL: 78.60NO.3TYPE AFFL: 78.60NO.2TYPE AFFL: 78.60NO.6TYPE AFFL: 77.90NO.5TYPE AFFL: 78.45NO.8TYPE AFFL: 77.30NO.7TYPE AFFL: 77.75NO.24TYPE D1FFL: 78.30NO.28TYPE CFFL: 78.30NO.23TYPE B2FFL: 78.75NO.22TYPE B1FFL: 78.75NO.25TYPE D1FFL: 77.30NO.27TYPE B1FFL: 77.75NO.29TYPE B3FFL: 78.30NO.21TYPE B1FFL: 79.20NO.30TYPE D2FFL: 78.30NO.20TYPE D2FFL: 79.20NO.26TYPE B2FFL: 77.75NO.15TYPE D1FFL: 78.30NO.12TYPE CFFL: 78.60NO.16TYPE B2FFL: 78.75NO.17TYPE B1FFL: 78.75NO.9TYPE D2FFL: 78.30NO.11TYPE B1FFL: 78.30NO.13TYPE B3FFL: 78.60NO.18TYPE B1FFL: 79.20NO.14TYPE D2FFL: 78.60NO.19TYPE D2FFL: 79.20NO.10TYPE B2FFL: 78.30F1MH size: 1200mmCL: 78.043mIL: 76.643mF2MH size: 1200mmCL: 77.024mIL: 75.661mF3MH size: 1200mmCL: 77.000mIL: 75.578mF4MH size: 1200mmCL: 78.232mIL: 74.713mF5MH size: 1200mmCL: 77.593mIL: 74.104mF6MH size: 1200mmCL: 77.483mIL: 74.076mF7MH size: 1200mmCL: 76.431mIL: 73.421mF9MH size: 1200mmCL: 71.030mIL: 67.934mF10MH size: 1200mmCL: 69.672mIL: 67.007mF_ExistMH size: 1200mmCL: 62.950mIL: 61.509mF14MH size: 1200mmCL: 79.023mIL: 77.673mF15MH size: 1200mmCL: 78.407mIL: 77.057mØ150mm Slope 1:17.2 Ø150mm Slope 1:45.0 Ø1 5 0mmSlop e 1 :7 0 . 3 Ø150mmSlope 1:70.0Ø225mmSlope 1:100.0Ø225m mSlope 1 : 1 0 0 . 8 Ø22 5mmSlope 1 : 22 . 0 Ø22 5 m m Slop e 1 : 2 2 . 0 Ø225mm Slope 1:22.0 Ø225mmSlope 1:22.0Ø150mmSlope 1:16.5F8MH size: 1200mmCL: 73.727mIL: 70.213mØ22 5 m m Slop e 1 : 2 2 . 0 F13MH size: 1200mmCL: 63.307mIL: 61.771mØ2 2 5 m m Slo p e 1 : 2 2 . 0F11MH size: 1200mmCL: 67.773mIL: 65.079mØ225mmSlope 1:22.0F12MH size: 1200mmCL: 65.668mIL: 62.672mØ225mmSlope 1:22.0Link NameSection Type ØSlope (1:X)Cover LevelInvert LevelLengthDatum 68.00071.60075.20078.80082.400F1479.023 2.000150mm17.277.67374.78849.521F478.232Bedding/BackFill14mm to 5mm graded aggregate or 10mm single sizedaggregateLink NameSection Type ØSlope (1:X)Cover LevelInvert LevelLengthDatum 67.00070.60074.20077.80081.400F1578.407 3.000150mm16.577.057 74.17947.399F577.593Bedding/BackFill14mm to 5mm graded aggregate or 10mmsingle sized aggregate© COPYRIGHT: These drawings are the copyright of CS Pringle Ltd. and they must not be reproduced without consent from this company.P|+353 42 9746492E|info@cspringle.comwww.cspringle.comFILE LOCATION: Geda Emyvale 6532\6. Planning\Drawings\SITEDATE:SCALES:REVISION:DRAWN BY:CHECKED BY:DRAWING NUMBER:ARCHITECTS | ENGINEERS | BUILDING SURVEYORSLOCATIONSTAGECLIENTHOUSING DEVELOPMENT EMYVALECSPringle■PLANNINGGEDA CONSTRUCTION CO. LTD.MARKET HOUSE LANE, EMYVALE, CO. MONAGHANMain St, Castleblayney,Co. Monaghan,A75 YR996532-CSP-P-GW/RMKOR007Nov 20251:500 @A1-FOUL SEWER SECTIONSFOUL SEWER PLANSCALE 1.1000PLANNING NOTE:THIS IS A PLANNING DRAWING ONLY. It is not a working drawing forconstruction and must not be used as such. The information on this drawing issuitable for fulfilling the requirements of the planning process only. Muchinformation of a structural nature will be missing from the drawing and someinformation required to comply with building regulations may be missing. It isstrongly recommended that the engineer be consulted for the preparation of fullworking drawings.FOUL SEWER SECTION S1-SExitSCALE 1.500SECTION S14-S4SCALE 1.500SECTION F15-F5SCALE 1.500RECEIVED: 12/12/2025 Link NameSection Type ØSlope (1:X)Cover LevelInvert LevelLengthDatum 61.00064.60068.20071.80075.40079.000S178.056 1.000225mm44.676.63175.60045.938S277.060 1.001225mm85.075.60075.4849.861S377.000 1.002225mm110.775.484 74.98155.672S578.298 1.003300mm188.574.906 74.57961.648S777.453 1.004300mm89.674.57974.5453.047NSBE015 #177.354 1.00567.774.44574.4003.046S877.256 1.006225mm29.074.400 74.1008.695S976.436 1.007225mm15.672.600 69.09054.810S1070.989 1.008225mm18.469.090 68.40912.508NSBE015 #269.864 1.00926.268.30968.2192.352S1169.705 1.010225mm11.568.21967.7585.310S1269.183 1.011225mm10.766.700 61.70253.387S1363.127 1.012225mm37.861.702 61.31214.733S_Ex.Gulley61.775Bedding/BackFill14mm to 5mm graded aggregate or 10mm single sized aggregate to IS EN 13242STOPSTOPSTOPNO.1TYPE AFFL: 78.15NO.4TYPE AFFL: 78.60NO.3TYPE AFFL: 78.60NO.2TYPE AFFL: 78.60NO.6TYPE AFFL: 77.90NO.5TYPE AFFL: 78.45NO.8TYPE AFFL: 77.30NO.7TYPE AFFL: 77.75NO.24TYPE D1FFL: 78.30NO.28TYPE CFFL: 78.30NO.23TYPE B2FFL: 78.75NO.22TYPE B1FFL: 78.75NO.25TYPE D1FFL: 77.30NO.27TYPE B1FFL: 77.75NO.29TYPE B3FFL: 78.30NO.21TYPE B1FFL: 79.20NO.30TYPE D2FFL: 78.30NO.20TYPE D2FFL: 79.20NO.26TYPE B2FFL: 77.75NO.15TYPE D1FFL: 78.30NO.12TYPE CFFL: 78.60NO.16TYPE B2FFL: 78.75NO.17TYPE B1FFL: 78.75NO.9TYPE D2FFL: 78.30NO.11TYPE B1FFL: 78.30NO.13TYPE B3FFL: 78.60NO.18TYPE B1FFL: 79.20NO.14TYPE D2FFL: 78.60NO.19TYPE D2FFL: 79.20NO.10TYPE B2FFL: 78.30S1MH size: 1200mmCL: 78.056mIL: 76.631mS3MH size: 1200mmCL: 77.000mIL: 75.484mØ225mm Slope 1:44.6 S5MH size: 1200mmCL: 78.298mIL: 74.906mØ225mmSlope 1:110.7S7MH size: 1200mmCL: 77.453mIL: 74.579mØ300mmSlope 1:188.5S11MH size: 1500mmCL: 69.705mIL: 68.219mS_Ex.GulleyCL: 61.775mIL: 61.312mØ 2 2 5 m m Sl o p e 1 : 1 1 . 5S4MH size: 1200mmCL: 79.048mIL: 77.623mØ225mm Slope 1:20.1 S6MH size: 1200mmCL: 78.425mIL: 77.000mØ225mmSlope 1:21.6Secondary StorageMH size: 1200mmCL: 70.566mIL: 68.319mØ225mmSlope 1 :95 .3S2MH size: 1200mmCL: 77.060mIL: 75.600mØ2 2 5mmSlop e 1 :8 5 . 0 S8MH size: 1200mmCL: 77.256mIL: 74.400mØ2 2 5mm Sl o p e 1 : 2 9 . 0 S10MH size: 1200mmCL: 70.989mIL: 69.090mØ225mm Slope 1:18.4Ø300mmSlope 1 :89 .6NSBE015 #1CL: 77.354mIL: 74.445mØ300mmSlope 1:67 .7S9MH size: 1200mmCL: 76.436mIL: 72.600mØ22 5 m m Slop e 1 : 1 5 . 6Main StorageMH size: 1200mmCL: 77.335mIL: 74.550mØ300mmSlope 1:31.5NSBE015 #2CL: 69.864mIL: 68.309mØ225mm Slope 1:26.2 S13MH size: 1200mmCL: 63.127mIL: 61.702mØ225mmSlope 1:37.8S12MH size: 1200mmCL: 69.183mIL: 66.700mØ225mmSlope 1:10.7EcoBloc Flex Attenuation #2:Storgae Vol: 12.48m³Size LxWxH units: 4x4x4 unitsSize LxWxH (m): 3.2x3.2x1.4mEcoBloc Flex Attenuation #1:Storgae Vol: 214.5m³Size LxWxH units: 22x10x5 unitsSize LxWxH (m): 17.6x8.0x1.75mControl Flow: HydrobrakeProduct No: CTL-SHE-0121-7600-1500-7600Control Flow: HydrobrakeProduct No: CTL-SHE-0108-7600-2500-7600© COPYRIGHT: These drawings are the copyright of CS Pringle Ltd. and they must not be reproduced without consent from this company.P|+353 42 9746492E|info@cspringle.comwww.cspringle.comFILE LOCATION: Geda Emyvale 6532\6. Planning\Drawings\SITEDATE:SCALES:REVISION:DRAWN BY:CHECKED BY:DRAWING NUMBER:ARCHITECTS | ENGINEERS | BUILDING SURVEYORSLOCATIONSTAGECLIENTHOUSING DEVELOPMENT EMYVALECSPringle■PLANNINGGEDA CONSTRUCTION CO. LTD.MARKET HOUSE LANE, EMYVALE, CO. MONAGHANMain St, Castleblayney,Co. Monaghan,A75 YR996532-CSP-P-GW/RMKOR009Nov 20251:500 @A1-STORM SEWER SECTIONS 01STORM SEWER PLANSCALE 1.1000PLANNING NOTE:THIS IS A PLANNING DRAWING ONLY. It is not a working drawing forconstruction and must not be used as such. The information on this drawing issuitable for fulfilling the requirements of the planning process only. Muchinformation of a structural nature will be missing from the drawing and someinformation required to comply with building regulations may be missing. It isstrongly recommended that the engineer be consulted for the preparation of fullworking drawings.STORM SEWER SECTION S1-S OUTSCALE 1.500RECEIVED: 12/12/2025 STOPSTOPSTOPEMBANKEMENTSSLOPE 1:2EMBANKEMENTSSLOPE 2:378.0073.2979.00EX 81.38580.0080.0077.5078.0178.0077.9180.0076.0070.2571.0171.7772.5373.2974.0574.8174.5776.3377.0977.6371.2572.2573.2574.2575.2576.2577.2577.5877.9178.2578.4578.6578.4578.2578.0077.7577.5077.2577.0077.0077.2577.5077.7578.0077.0078.0077.75EX 72.00EX 72.0078.2178.3178.41EX 63.0078.0578.3578.6578.9578.4579.00EX 81.385NO.1TYPE AFFL: 78.15NO.4TYPE AFFL: 78.60NO.3TYPE AFFL: 78.60NO.2TYPE AFFL: 78.60NO.6TYPE AFFL: 77.90NO.5TYPE AFFL: 78.45NO.8TYPE AFFL: 77.30NO.7TYPE AFFL: 77.75NO.24TYPE D1FFL: 78.30NO.28TYPE CFFL: 78.30NO.23TYPE B2FFL: 78.75NO.22TYPE B1FFL: 78.75NO.25TYPE D1FFL: 77.30NO.27TYPE B1FFL: 77.75NO.29TYPE B3FFL: 78.30NO.21TYPE B1FFL: 79.20NO.30TYPE D2FFL: 78.30NO.20TYPE D2FFL: 79.20NO.26TYPE B2FFL: 77.75NO.15TYPE D1FFL: 78.30NO.12TYPE CFFL: 78.60NO.16TYPE B2FFL: 78.75NO.17TYPE B1FFL: 78.75NO.9TYPE D2FFL: 78.30NO.11TYPE B1FFL: 78.30NO.13TYPE B3FFL: 78.60NO.18TYPE B1FFL: 79.20NO.14TYPE D2FFL: 78.60NO.19TYPE D2FFL: 79.20NO.10TYPE B2FFL: 78.30S1MH size: 1200mmCL: 78.056mIL: 76.631mS3MH size: 1200mmCL: 77.000mIL: 75.484mØ225mmSlope 1:44.6 S5MH size: 1200mmCL: 78.298mIL: 74.906mØ225mmSlope 1:110.7S7MH size: 1200mmCL: 77.453mIL: 74.579mØ300mmSlope 1:188.5S11MH size: 1500mmCL: 69.705mIL: 68.219mS_Ex.GulleyCL: 61.775mIL: 61.312mØ 2 2 5 m m Sl o p e 1 : 1 1 . 5S4MH size: 1200mmCL: 79.048mIL: 77.623mØ225mm Slope 1:20.1 S6MH size: 1200mmCL: 78.425mIL: 77.000mØ225mmSlope 1:21.6Secondary StorageMH size: 1200mmCL: 70.566mIL: 68.319mØ225mmSlope 1:95.3S2MH size: 1200mmCL: 77.060mIL: 75.600mØ225mmSlope 1:85.0S8MH size: 1200mmCL: 77.256mIL: 74.400mØ2 2 5mm S l o p e 1 : 2 9 . 0 S10MH size: 1200mmCL: 70.989mIL: 69.090mØ225mm Slope 1:18.4Ø300mmSlope 1:89.6NSBE015 #1CL: 77.354mIL: 74.445mØ300mmSlope 1:67.7S9MH size: 1200mmCL: 76.436mIL: 72.600mØ2 2 5 m m Slo p e 1 : 1 5 . 6Main StorageMH size: 1200mmCL: 77.335mIL: 74.550mØ300mmSlope 1:31.5NSBE015 #2CL: 69.864mIL: 68.309mØ225mm Slope 1:26.2 S13MH size: 1200mmCL: 63.127mIL: 61.702mØ225mmSlope 1:37.8S12MH size: 1200mmCL: 69.183mIL: 66.700mØ225mmSlope 1:10.7EcoBloc Flex Attenuation #2:Storgae Vol: 12.48m³Size LxWxH units: 4x4x4 unitsSize LxWxH (m): 3.2x3.2x1.4mEcoBloc Flex Attenuation #1:Storgae Vol: 214.5m³Size LxWxH units: 22x10x5 unitsSize LxWxH (m): 17.6x8.0x1.75mControl Flow: HydrobrakeProduct No: CTL-SHE-0121-7600-1500-7600Control Flow: HydrobrakeProduct No: CTL-SHE-0108-7600-2500-7600KEYSTORM SEWER© COPYRIGHT: These drawings are the copyright of CS Pringle Ltd. and they must not be reproduced without consent from this company.P|+353 42 9746492E|info@cspringle.comwww.cspringle.comFILE LOCATION: Geda Emyvale 6532\6. Planning\Drawings\SITEDATE:SCALES:REVISION:DRAWN BY:CHECKED BY:DRAWING NUMBER:ARCHITECTS | ENGINEERS | BUILDING SURVEYORSLOCATIONSTAGECLIENTHOUSING DEVELOPMENT EMYVALECSPringle■PLANNINGGEDA CONSTRUCTION CO. LTD.MARKET HOUSE LANE, EMYVALE, CO. MONAGHANMain St, Castleblayney,Co. Monaghan,A75 YR996532-CSP-P-GW/RMKOR008Nov 20251:500 @A1-STORM SEWER PLANNORTHRECEIVED: 12/12/2025 STOPSTOPSTOPNO.1TYPE AFFL: 78.15NO.4TYPE AFFL: 78.60NO.3TYPE AFFL: 78.60NO.2TYPE AFFL: 78.60NO.6TYPE AFFL: 77.90NO.5TYPE AFFL: 78.45NO.8TYPE AFFL: 77.30NO.7TYPE AFFL: 77.75NO.24TYPE D1FFL: 78.30NO.28TYPE CFFL: 78.30NO.23TYPE B2FFL: 78.75NO.22TYPE B1FFL: 78.75NO.25TYPE D1FFL: 77.30NO.27TYPE B1FFL: 77.75NO.29TYPE B3FFL: 78.30NO.21TYPE B1FFL: 79.20NO.30TYPE D2FFL: 78.30NO.20TYPE D2FFL: 79.20NO.26TYPE B2FFL: 77.75NO.15TYPE D1FFL: 78.30NO.12TYPE CFFL: 78.60NO.16TYPE B2FFL: 78.75NO.17TYPE B1FFL: 78.75NO.9TYPE D2FFL: 78.30NO.11TYPE B1FFL: 78.30NO.13TYPE B3FFL: 78.60NO.18TYPE B1FFL: 79.20NO.14TYPE D2FFL: 78.60NO.19TYPE D2FFL: 79.20NO.10TYPE B2FFL: 78.30S1MH size: 1200mmCL: 78.056mIL: 76.631mS3MH size: 1200mmCL: 77.000mIL: 75.484mØ225mm Slope 1:44.6 S5MH size: 1200mmCL: 78.298mIL: 74.906mØ225mmSlope 1:110.7S7MH size: 1200mmCL: 77.453mIL: 74.579mØ300mmSlope 1:188.5S11MH size: 1500mmCL: 69.705mIL: 68.219mS_Ex.GulleyCL: 61.775mIL: 61.312mØ 2 2 5 m m Sl o p e 1 : 1 1 . 5S4MH size: 1200mmCL: 79.048mIL: 77.623mØ225mm Slope 1:20.1 S6MH size: 1200mmCL: 78.425mIL: 77.000mØ225mmSlope 1:21.6Secondary StorageMH size: 1200mmCL: 70.566mIL: 68.319mØ225mmSlope 1 :95 .3S2MH size: 1200mmCL: 77.060mIL: 75.600mØ2 2 5mmSlop e 1 :8 5 . 0 S8MH size: 1200mmCL: 77.256mIL: 74.400mØ2 2 5mm Sl o p e 1 : 2 9 . 0 S10MH size: 1200mmCL: 70.989mIL: 69.090mØ225mm Slope 1:18.4Ø300mmSlope 1 :89 .6NSBE015 #1CL: 77.354mIL: 74.445mØ300mmSlope 1:67 .7S9MH size: 1200mmCL: 76.436mIL: 72.600mØ22 5 m m Slop e 1 : 1 5 . 6Main StorageMH size: 1200mmCL: 77.335mIL: 74.550mØ300mmSlope 1:31.5NSBE015 #2CL: 69.864mIL: 68.309mØ225mm Slope 1:26.2 S13MH size: 1200mmCL: 63.127mIL: 61.702mØ225mmSlope 1:37.8S12MH size: 1200mmCL: 69.183mIL: 66.700mØ225mmSlope 1:10.7EcoBloc Flex Attenuation #2:Storgae Vol: 12.48m³Size LxWxH units: 4x4x4 unitsSize LxWxH (m): 3.2x3.2x1.4mEcoBloc Flex Attenuation #1:Storgae Vol: 214.5m³Size LxWxH units: 22x10x5 unitsSize LxWxH (m): 17.6x8.0x1.75mControl Flow: HydrobrakeProduct No: CTL-SHE-0121-7600-1500-7600Control Flow: HydrobrakeProduct No: CTL-SHE-0108-7600-2500-7600Link NameSection Type ØSlope (1:X)Cover LevelInvert LevelLengthDatum 68.00071.60075.20078.80082.400S479.048 2.000225mm20.177.62374.98153.221S578.29814mm to 5mm graded aggregate or 10mm single sizedaggregate to IS EN 13242Bedding/BackFillLink NameSection Type ØSlope (1:X)Cover LevelInvert LevelLengthDatum 68.00071.60075.20078.80082.400S678.425 3.000225mm21.677.000 74.65450.753S777.45314mm to 5mm graded aggregate or 10mm single sizedaggregate to IS EN 13242Bedding/BackFillLink NameSection Type ØSlope (1:X)Cover LevelInvert LevelLengthDatum 67.00070.60074.20077.80081.400MainStorage77.335 4.000300mm31.574.550 74.4004.724S877.25614mm to 5mm graded aggregate or 10mmsingle sized aggregate to IS EN 13242Bedding/BackFillLink NameSection Type ØSlope (1:X)Cover LevelInvert LevelLengthDatum 60.00063.60067.20070.80074.400SecondaryStorage70.566 5.000225mm95.368.31968.2199.504S1169.70514mm to 5mm graded aggregate or 10mmsingle sized aggregate to IS EN 13242Bedding/BackFill© COPYRIGHT: These drawings are the copyright of CS Pringle Ltd. and they must not be reproduced without consent from this company.P|+353 42 9746492E|info@cspringle.comwww.cspringle.comFILE LOCATION: Geda Emyvale 6532\6. Planning\Drawings\SITEDATE:SCALES:REVISION:DRAWN BY:CHECKED BY:DRAWING NUMBER:ARCHITECTS | ENGINEERS | BUILDING SURVEYORSLOCATIONSTAGECLIENTHOUSING DEVELOPMENT EMYVALECSPringle■PLANNINGGEDA CONSTRUCTION CO. LTD.MARKET HOUSE LANE, EMYVALE, CO. MONAGHANMain St, Castleblayney,Co. Monaghan,A75 YR996532-CSP-P-GW/RMKOR010Nov 20251:500 @A1-STORM SEWER SECTIONS 02STORM SEWER PLANSCALE 1.1000PLANNING NOTE:THIS IS A PLANNING DRAWING ONLY. It is not a working drawing forconstruction and must not be used as such. The information on this drawing issuitable for fulfilling the requirements of the planning process only. Muchinformation of a structural nature will be missing from the drawing and someinformation required to comply with building regulations may be missing. It isstrongly recommended that the engineer be consulted for the preparation of fullworking drawings.SECTION S4-S5SCALE 1.500SECTION S6-S7SCALE 1.500SECTION MAIN STORAGE-S8SCALE 1.500SECTION SECONDARY STORAGE-S11SCALE 1.500RECEIVED: 12/12/2025