HomeMy WebLinkAbout2560533 - Report Received from Internal Staff - Fire Monaghan Fire & Civil Protection Monaghan Fire Station Annahagh Monaghan Co. Monaghan 12/02/2026 Planning Section, Monaghan County Council, The Glen, Monaghan Planning App. Ref. No. 25/60533 Applicant Fine Living Timber Frames Ltd retention permission for an existing external yard storage building with full permission sought for a change of use from an existing retail outlet (RB Coogan) to a timber frame manufacturing facility with ancillary office and staff facilities; etc. No objections to the Planning Application subject to the following conditions: 1. The proposed development shall obtain a fire safety certificate in accordance with S.I. No. 305/1991 – Building Control Regulations, 1991, prior to construction (Individual applications required for individual buildings). 2. The proposed works shall be designed and constructed in accordance with the requirements of Part B Fire Safety 2024, of the Second Schedule of the Building Regulations, 1997-2024. a. Adequate means of escape shall be provided from the building so as to satisfy travel distance as outlined in Technical Guidance Document B. b. Where the building constitutes ‘High risk’ as defined in Appendix D of Technical Guidance Document Part B Fire Safety 2024, please submit your application as Purpose Group 6 (b) and ensure adequate provisions are in place to comply with the requirements specified. c. Ventilation - Single storey Industrial buildings exceeding 4,000m2 in area requires roof ventilation facilities and provisions of inlet air in accordance with Section 6.7 of Technical Guidance Document Part B Fire Safety 2024. 3. Any buildings work to be retained shall obtain a Regularisation Fire Safety Certificate in accordance with S.I. No. 351/2009 Building Control (Amendment) Regulations, 2009. 4. Fire Hydrants shall be located in accordance with Section 5.3 of Technical Guidance Document Part B Fire Safety 2024. 5. Fire Hydrants shall be in accordance with BS 750:2012 and shall deliver a minimum rate of flow as per Monaghan Fire & Civil Protection ‘Guidance document for fire-fighting water supplies’. 6. Fire Brigade Vehicle access shall be provided in accordance with Clause 5.4 of Technical Guidance Document Part B Fire Safety 2024 including turning facilities where dead-ends exceed 20.0m. 7. The proposed works shall be designed and constructed in accordance with Part M Access & Use, of the Second Schedule of the Building Regulations, 1997-2022. 8. The proposed works shall obtain a Disability Access Certificate in accordance with S.I. No. 351/2009 - Building Control (Amendment) Regulations 2009, prior to construction. Regards Dermot Brannigan Chief Fire Officer