Loading...
HomeMy WebLinkAbout2660003 - Report Received from Internal Staff - Environment No 2ENVIRONMENTAL REPORT To: Donna McEvoy – A/Executive Scientist. From: Martina McPhillips (Environment Section – Waste Team) Re: 26/60003 Monaghan Harps GAA Club, Roosky, Monaghan Town, Co. Monaghan. Consultants: Coyle Civil & Structural Ltd. Permission: … permission will consist of construction of a new astro turf playing pitch with 2.40m high metal perimeter fencing and associated netting (combined height 6.40m), 4 no. 12m high columns with 2 floodlights per column, changes to front elevation of existing club house to include the removal of existing front door, to be replaced with a new curtain panel system new storage/maintenance shed with a new car parking area, connection to existing foul rising main and all associated site works. Planner: Liam Ward Date: 05/02/2026 __________________________________________________________________________________ Background The proposed development is located on a Regionally Important Fissured Bedrock aquifer in an area of Moderate groundwater vulnerability. The development site is located within the Blackwater[Monaghan] SC 010 subcatchment which has been assigned Good ecological status under the Water Framework Directive. The site is located within a pluvial extreme zone as viewed on the OPW flood maps which suggests low-lying area at risk of flooding Pressures include Agriculture, Urban Waste Water and Urban Run-off. Shamble_010 is the nearest watercourse which is approximately 120 meters from the site. No Water Protection Checklist has been submitted with the application. A Site Layout Plan has been received with the application. The plan lacks clarity on how surface water will be managed on the site. No information has been provided regarding the drainage from the proposed car parking area or the proposed finished i.e. Concrete/Tarmac for car parking spaces incorporated within the site. The number of required car parking spaces has not been specified; however, the site layout plan shows 14 spaces. The development site is currently connected to the public sewer. The Site Layout plan states a new rising main to existing foul drainage but No Pre-Connection Enquiry from Uisce Éireann received with application. Recommendation I therefore request the following information. A) Submit a revised site layout plan (Scale 1:500). This plan shall clearly mark I. The existing and proposed storm water drainage system (blue) and the location of any manholes and the outfall points and direction of flows. II. The existing and proposed foul wastewater drainage system (red). III. Submit details on the proposed car parking area to include • How surface water arising from the proposed carpark will be managed. • Submit design specification details for petrol Interceptor to demonstrate adequate capacity. • Submit proposed finished i.e. Concrete/Tarmac for car parking spaces. • Include existing and proposed oil/petrol interceptors and the location of outfall and drainage area. B) Submit a Construction & Environmental Management Plan (CEMP) to Monaghan County Council for consideration. I. A Construction and Demolition Plan and By-Products Management Plan for the proposed development works shall be provided using “Best Practice Guidelines for the preparation of resource & waste management plans for construction and demolition projects” – EPA, 2021. II. An Asbestos survey and removal plan for the proposed development works. C) Submit a site-specific Flood Risk Assessment. D) Submit a Confirmation of Feasibility from Uisce Éireann to assess feasibility and identify necessary infrastructure upgrades to the development. Prepared By: Date: 05/02/2026 Environment Technician Approved Date: 05/02/20206 A/Executive Scientist