Loading...
HomeMy WebLinkAbout2560533 - F.I. Maps - Plans, Sections, ElevationsDRAWING TITLE: CLIENT: USE FIGURED DIMENSIONS ONLY PROJECT: SCALE:1:100 NOTES: THIS DRAWING IN WHOLE OR IN PART SHALL NOT BE COPIED WITHOUT THE PRIOR PERMISSION OF BERNARD DOWDALL - ARCHITECT. ALL WORKS TO COMPLY WITH THE CURRENT BUILDING REGULATIONS. DO NOT SCALE. 1. 2. 3. NOTES: UNLESS SPECIFICALLY NOTED AS "BY OTHERS" THE MAIN CONTRACTOR IS TO SUPPLY AND INSTAL ALL MATERIALS AND BUILDING ELEMENTS INDICATED ON THE DRAWINGS AND ASSOCIATED SPECIFICATIONS. CLIENT, CONTRACTOR & NOMINATED SUPPLIER LISTS ARE NOTED IN THE PROJECT PRELIMENARY DOCUMENT. NOTE: The architect's drawings and specification are indicative of design intent only and define the performance criteria. The relevant specialist sub-contractors for each specialist envelope package shall be fully responsible for developing and completing the design in accordance with the above and other Contract Documents, taking into account any additional criteria which, with his specialist knowledge, he believes are relevant. The envelope specialist subcontractors are responsible for coordination and completion of all whole system specifications and drawings, in accordance with requirements of all manufacturer warranty conditions. IMPORTANT Health, Safety & Environmental Information 1.The above documents and drawings show hazards that have become apparent to the designer at the time of issue and is not an exhaustive list. It should be noted that hazards not yet identified remain to be documented. 2.The above documents and drawings show only specific or unusual hazards and information that may be useful to those constructing or maintaining the works. Generic and obvious hazards that a competent contractor would identify and mitigate against are not shown. 3.These drawings should be read in accordance with proposed and existing utilities drawings. Utilities have not been shown to avoid congestion. 4.All design work (including permanent, temporary and specialist works) to be coordinated through the Project Supervisor Design Process (PSDP). 5.It is assumed that all works will be carried out by competent contractors working to an approved method statement. BERNARD DOWDALL ARCHITECTS Carrickedmond, Kilcurry, Dundalk, Co. Louth. TELEPHONE: 042 9429558 MOB: 087 6657148 EMAIL: bernard@dowdallarchitects.ieRefer to the Safety and Health Plan for hazards and risks associated with this type of work. A1. at 1:100 DATE: DRAWING NUMBER: DRAWING SUBJECT TO COPYRIGHT © EXTERNAL STORE DETAILS - FOR RETENTION & PROP.EXTENSION 2558- P - 303 - B 25 FEBRUARY 2026 A 12/12/2025 FOR PLANNING PURPOSES ONLY ISSUE. FOR PLANNING PURPOSES ONLY. PROPOSED GROUND FLOOR PLAN Scale 1:100 @ A1 Proposed External Store Area PROPOSED SECTION BB Scale 1:100 @ A1 Metal Gutters Steel Column PROPOSED NORTH-EASTERN ELEVATION Scale 1:100 @ A1 Metal Gutters Steel Column PROPOSED SOUTH-WESTERN ELEVATION Scale 1:100 @ A1 Steel Column 01 02 04 05 06 07 08 18000 20006 Existing External Store Area for RetentionProposed External Store Area 01 1800020006 Existing External Store Area for Retention Proposed External Store Area PROPOSED NORTH-WESTERN ELEVATION Scale 1:100 @ A1 PROPOSED SOUTH-EASTERN ELEVATION Scale 1:100 @ A1 ABC A B C Existing Structures. Proposed Structures. Existing External Store Area for Retention. Proposed External Store Area. 8139 8139 Metal Gutters FINE LIVING TIMBER FRAME LTD. CHANGE OF USE FROM A RETAIL OUTLET TO MANUFACTURING FACILITY AT LAKEVIEW BUSINESS PARK, CASTLEBLAYNEY, COUNTY MONAGHAN. 5440 4690 4690 5440 5440 4690 5440 PROPOSED FLOOR AREAS. EXISTING FLOOR AREA = 167.3 sq.m. PROPOSED FLOOR AREA = 146.4 sq.m. TOTAL FLOOR AREA = 313.7sq.m. 4690 5440 B B 8367 Proposed External Store Area Existing External Store Area 2000618000 Existing External Store Area for RetentionProposed External Store Area 38006 6000 6000 6000 5013 4990 4990 5013 5617 2522 8139 01 02 04 05 06 07 08 A B C for Retention 03 03 02040506070803 Existing Corrugated Metal Sheeting to be Painted Saragossa Existing Corrugated Metal Sheeting to be Painted Saragossa Existing Corrugated Metal Sheeting to be Painted Saragossa Existing Corrugated Metal Roofing to be Painted Saragossa B 25/02/2026 FOR F.I. PLANNING PERMISSION PURPOSES ISSUE. Existing Corrugated Metal Sheeting to be Painted Saragossa Existing Corrugated Metal Sheeting to be Painted Saragossa RECEIVED: 16/03/2026