Loading...
HomeMy WebLinkAbout2660052 - Chief Executives AI OrderMONAGHAN CO. COUNCIL PLANNING AND DEVELOPMENT ACT 2000 (as amended) Chief Executive's Order No: Reference Number: Name of Applicant: Address: Nature of Application: Location of Development: ORDER: P328-26ai 26/60052 Annayalla Chicks Sam Nicholson A-Tek Building, Unit 2 4 Edenaveys Industrial Estate Armagh Permission for a development which will consist of a) decommissioning and removal of existing wastewater treatment plant and percolation area and b) installation of new treatment plant comprising a cast in -situ concrete compartmented tank structure with four biozones, balancing tank, sludge storage tank, final settlement tank, control room and aeration blower on a cast in -situ concrete plinth with fenced enclosure, c) 1670m2 reed and willow bed tertiary treatment and polishing system d) new discharge to existing surface water course, together with e) associated external works including new access to existing adjacent service yard, connections to all existing services Annayalla Chicks Ltd Annayalla Castleblaney Co Monaghan I hereby order that pursuant to the provisions of the Planning and Development Act 2000 (as amended) and Article 33 of the Planning and Development Regulations 2001 (as amended), the further information set out on the attached schedule be requested from the applicant. SENIOR PLANNER DATE 26/60052 Annayalla Chicks Annayalla Chicks Ltd, Annayalla, Castleblaney Co Monaghan ADDITIONAL INFORMATION Note: Your assigned agent should liaise with the Council's Environment Section prior to the preparation and submission of this Further Information. 1. The information submitted is insufficient with regards environmental protection. In the interest of clarity and to allow for a fully informed decision, please submit: (a) A revised site layout plan (1:500) demonstrating the following: (i) All existing and proposed surface/storm water drainage systems (outlined in blue). (ii) The directional flow of all existing/proposed surface water pipelines. (iii) Any interceptors servicing the carparking and/or yard areas. (iv) Any SuDS measures. (v) All associated discharge points and outfalls. (vi) The truck wash area. (vii) The proposed wastewater treatment plant. (viii) All existing and proposed foul water drainage systems (outlined in red). The revised site layout shall clearly demonstrate separate discharge routes for storm and wastewater from the site. (b) An appropriately completed water protection plan checklist. The planner dealing with this application is Ben Clerkin