Loading...
HomeMy WebLinkAbout2660139 - Report Received from Internal Staff - MDMMOONNAAGGHHAANN CCOOUUNNTTYY CCOOUUNNCCIILL CCAARRRRIICCKKMMAACCRROOSSSS--CCAASSTTLLEEBBLLAAYYNNEEYY MMUUNNIICCIIPPAALL DDIISSTTRRIICCTT PPLLAANNNNIINNGG PPEERRMMIISSSSIIOONN –– RROOAADD CCOONNDDIITTIIOONN RREEPPOORRTT Planning Application No. 26/60139 Previous Ref.No’s. 24-60241 Applicant: Anna & Bernie Carragher, Address: Proposed Development: Change of house type and design from two-storey to single storey dwelling and relocation of dwelling within site from that previously granted under Planning Reference No.24-60241, together with all associated site works. Location: Lislanly, Castleblayney, Co. Monaghan Adjoining Road No. LP3410 Site Notice: Yes No Date: 22/5/2026 Engineer’s Report I understand the current replacement house policy and its relation to sightlines. I have applied standard conditioning below. A Sight Distance 70m is not achievable to the right on the LP3410 as it is through a National Primary roundabout. No Objection Subject to the Following Conditions: 1. The existing entrance to form a bellmouth of 4.0 metres radius with edge of boundary. Entrance gates to open inwards only. Recessed entrance to be of sufficient dimensions to contain a stationary vehicle off the Laneway. 2. Sight Distances Sight distance of 35 metres be provided from a point in the entrance 3.0 metres from the road edge and 1.05 metre above ground level were the entrance meets the private road. Sight distances to be measured to the nearside road edge in both directions. Where it is necessary remove hedges/crash barrier in order to achieve this sight distance. 3. The line of any new fence or wall must be positioned behind the visibility splays. Any new trees or shrubs to planted back from the visibility splays to allow for future growth and some species will require additional set back. All planting must be kept trimmed and must not impede on the visibility splays. Where a timber post and rail fence is erected along road boundary, the timber rails to be placed on the site side of posts, in the interest of road safety. 4. The Area within the visibility splays shall be cleared to provide a level surface no higher than 250 mm above the level of the adjoining carriageway and shall be retained and kept clear thereafter. 5. Area between road edge and new boundaries to be soled with 300mm of 100mm stone blinded with quarry dust and rolled to level and camber of existing road. MMOONNAAGGHHAANN CCOOUUNNTTYY CCOOUUNNCCIILL CCAARRRRIICCKKMMAACCRROOSSSS--CCAASSTTLLEEBBLLAAYYNNEEYY MMUUNNIICCIIPPAALL DDIISSTTRRIICCTT 6. Any new boundary or entrance work to be located not less than 3.0 metres from the public road carriageway with level margin to allow for passing vehicles on Public road along full site frontage. 7. Entrance/Access road to be surfaced with concrete or bitmac from edge of public road for a minimum of 5 metres. 8. Entrance between road carriageway and boundary to graded back so that level at boundary (3.0 metres) to be 100 mm below road level. 9. Gradient of access road to be not greater than 1:20 (5.0%) for the first 5 metres from boundary and 1:10 (10.0%) thereafter. 10. French drain consisting of 300 mm diameter concrete pipes backfilled to ground level with suitable granular filter material to be placed along full site frontage. Drain to discharge to the nearest watercourse. Suitable gullies to be placed at start, end, and intersection of other drains and at not greater than 40 metres intervals. (Separate application to be made to Monaghan County Council if this requires a road opening licence). 11. Applicant to install Cattlegrid/Gullies at proposed entrance constructed in such a manner as to prevent water from the entrance flowing onto the public road. Similarly measures must be taken to prevent road surface water from flowing onto the entrance. The discharge from the above to be piped to drainage pipeline. 12. The discharge of surface water from the public road onto the site through road surface drainage and road subsoil drainage to remain unimpeded. 13. Provision to be made within the site for surface water drainage and no surface water to be allowed flow onto the public roadway. 14. No development exempt or otherwise shall be erected over the public sewer, drain or water main. 15. Before any work is commenced on this development a security, by way of a cash deposit, in the sum of €2,250.00 is to be paid to the Planning Authority by the developer. To ensure the satisfactory completion of all surface water drainage/boundary work within and abutting the site area, to prevent runoff of surface water onto the public roadway and to ensure that no damage is caused to public roadway and any such damage is repaired satisfactory. Signed: Paraic Lally DATE: 22/5/26. Paraic Lally Assistant Engineer Carrickmacross Municipal District