HomeMy WebLinkAbout2560469 - F.I. Received Doc. - Water Protection ChecklistMONAGHAN LOCAL AUTHORITIES
Environment Protection Plan Checklist
This is a checklist to be completed by applicant to be backed up by an appropriate level of
detail depending. To be accompanied by a Site Drainage Plan – as set out in the Monaghan
County Development Plan 2025 – 2031.
General Site and Water Body Details
Planning Ref. No. 25/60469 Applicant
Townland Dundrumman Water Supply
Source
N/A
X Co-ordinate 1 54.276336 Y Co-ordinate 1 -7.130878
WFD River Sub Catchment2 Finn[Monaghan]_SC_010 WFD River Sub
Basin2
Maghery_10
WFD River
Waterbody
Objective2
Not deteriorate in status
because of a new activity or
development
WFD River Waterbody
latest Status 2
Status Year WFD River
Waterbody
Risk2
At risk
Poor 2019-2024
Groundwater Vulnerability 3 Low Aquifer
Importance 3
Locally Important
Proximity to sensitive receptors (Private Wells, Public and Private Water
Supply
Sources, Amenity Areas, SPA’s, SAC’s , NHA) (meters)
• Approximately 2,000m
south of Slieve Beagh SPA
(Nearest European Site)
• Approximately 3,164m
away from Eshbrack Bog
NHA (closest NHA from the
Proposed Development)
• Approximately 3,232m
away from Kilcoran Lough
pNHA (closest pNHA)
• Approximately 490m from
the set back area from a
groundwater well
(2333SEW053).
• Approximately 1,420m from
Tydavnet
(IE_GSI_SPA_203) which
is the closest Group Water
Scheme Publix Supply
Source Protection Area
outer zone.
Proximity to nearest watercourse (culverted or open), wetland or lake
(meters)
Approximately 135m from the
Maghery Stream (culverted).
Existing EPA Licence (insert licence no) N/A
Existing Section 4 licence (insert licence no) N/A
Proposed Development
Is the development entirely or part of one of the following? (tick)
Domestic dwelling Agricultural
(cattle/dairy)
Industrial-food related
Public Works Agricultural Industrial-non food RECEIVED: 26/05/2026
(mushrooms)
Housing Agricultural (poultry) Quarrying/extractive
industries
Institutional Agricultural (piggery) Transport related
Commercial/Retail Other agricultural –
specify below
Filling station/Fuel depot
Mixed Use Development Other
Type of wastewater Produced by the proposed development (tick)
No wastewater produced √
Domestic type waste waters ×
Domestic type waste waters >5m3 per day 4 ×
Waste waters produced from any trade, food, preparation or business 4 ×
Wheel wash, vehicle wash, cooling waters 4 ×
Waste waters produced from quarrying etc 4 ×
Other waste waters 4 ×
Have proposals for Wastewater Management during the operational phase and full details of same
been included with the application? (tick)
Public Sewer Connection details (Uisce Eireann) ×
Existing Wastewater Treatment System √
Proposed new onsite wastewater treatment
system
×
No wastewater generated √
Have proposals for Waste Facility aftercare and use been included with the application? (tick)
Agricultural Improvement Plan where applicable ×
Closure plan and aftercare details ×
Proposed water sampling locations clearly identified √
License or Lease agreement for the site if not owned by the applicant. ×
Fuel or Outdoor Material Storage for Non Domestic Developments
Number of fuel storage tanks existing or proposed on site? 0
Are fuel storage tanks bunded 5? N/A
Detail liquid / feedstuffs / organic / chemical
/ waste oil storage on outdoor sites
N/A
Proposals for protection of water receptors during the Construction Phase
Has a CEMP relating to water protection
and waste management been included with
the application?
A CEMP has been included as part of the planning
application. Water protection measures have been informed
by a thorough Water Framework Directive (WFD) assessment
and a water sampling plan shall form part of the CEMP (See
Appendix 1 of the CEMP).
Name of person appointed to oversee the
implementation of the CEMP.
The appointed EnvCoW and the appointed contractor.
Hard Surface and Open Yard Areas for Non Domestic Developments
Footprint of proposed development including yard areas in
m2
• Approximately 210.25 m2 for the
foundation of the proposed wind
turbine.
• Approximately 560m2 for the access
track.
• Approximately 500 m² for the crane
hardstanding
Is there potential for soiled yard areas from material,
product waste or manure handling, fuel dispensing, silt
and soil, yard washing etc.
√
If yes, are silt trap(s), interceptor(s), soiled water tanks or
other control measures shown on drainage plan?
√
Has the use of SUDS (Sustainable Urban Drainage
Systems – http://www.susdrain.org ) been considered in the
√ RECEIVED: 26/05/2026
design of this development?
Development History – All Developments
Have previous pollution prevention planning conditions been complied with 6? √
Does existing development have an up to date (as constructed) site drainage plan? √
Is the existing/proposed development sewered or unsewered? N/A
If unsewered, is the existing wastewater treatment system fit for purpose7? N/A
Has the storm water drainage system been examined and/or surveyed for misconnections?
(Information leaflet available from Environment Section)
N/A
Is there an existing Certificate of Registration or Waste Facility Permit at the site? N/A
Checklist of items to be included on Site Drainage Plan(tick)
Location of lakes, watercourse, wells used for water supply, or karst features on or within
25m of domestic or 100m of non domestic development site
√
Location of all drainage outfall points √
Foul water drainage system (in Red) N/A
Storm water drainage system (in Blue) N/A
Soiled yard area, soiled water drainage and management system √
Storm water management system, including silt traps, oil interceptor(s) and SUDS facilities √
Location of waste water treatment facilities N/A
Location of fuel storage tank(s) N/A
Stream/Lake/Wetland/Riparian Corridors/Wells √
Footnotes and Useful Information
1 Projection in the Irish Grid
2 WMU, RWB, WB status. Objectives available on water maps at www.wfdireland.ie
3 Available in the public mapping section at www.gsi.ie
4 For information leaflets on Business Premises and Proper Use of Drains and information on discharge
licensing see:
http://www.monaghan.ie/contentv3/services/environment/formsguidesdocumentsdownlands/
http://www.monaghan.ie/contentv3/services/environemtn/water/waterawareness/leaftletsandguidelines/
5 Guidance: www.envirocentre.ie Best practice for Oil Storage (BPGCS05)
6 Has certification of installation for previously granted wastewater treatment system been required and if so
has it been submitted.
7 Refer to EPA Guidance at:
http://www.monaghan.ie/contentv3/services/environment/water/waterawareness/faqforseptictanks/ and
http://www.monaghan.ie/contentv3/media/monaghanie/content/files/pdf/environment/Water
Pollution&DrainageSystems.pdf
8 Refer to Water Body, Sensitive Waters and Sensitive Land Maps in Chapter 4 of the Monaghan County
Development Plan 2013-2019
Abbreviations
WMU Water Management Unit
RWB River Water Body
WB Status Water Body Status
IPPC Integrated Pollution Prevention Control Licence
EIA Environmental Impact Assessment
For Office Use: Sensitivity of Location
Is the development located upstream of a high
river quality site 8?
×
Is the development located within a good status
waterbody 8?
×
Is the development located in the catchment of a
water supply source 8?
Yes, the Proposed Development is located within the
Erne (ID 36) and shares the same catchment as Unshin
lake (IE_NW_36_712), Lough Melvin (IE_NW_35_160),
Garvagh Lough Trib (UKGBNI1SH262601001),
OWENSALLAGH_010 River (IE_NW_36O010800),
ERNE_090 River (IE_NW_36E011410), FINN
(MONAGHAN)_030 River (IE_NW_36F010400),
ANNALEE_050 River (IE_NW_36A020600), Coragh RECEIVED: 26/05/2026
Lake (IE_NW_36_460), Baraghy Lake (IE_NW_36_635),
White Rockcorry lake (IE_NW_36_647), Killcoran Lake
(IE_NW_36_329), Drumgole Lake (IE_NW_36_415),
Killynenagh Lake (IE_NW_36_409).
Is the development located within the Source
Protection Zone (SPZ) of a groundwater supply
source 8?
×
Does the development require a discharge
licence to surface or ground waters under the
Water Pollution Acts?
×
Risk to waters in relation to scale of
development, previous planning/environmental
history, IPPC or EIA aspects, site management
and location in a sensitive area
×
Applicant:
Agent:_____James Glackin_____________________Date________12/05/2026_____
RECEIVED: 26/05/2026
RECEIVED: 26/05/2026
RECEIVED: 26/05/2026