Loading...
HomeMy WebLinkAbout2660057 - F.I. Maps - Site layout planREVISION: Figured dimensions ONLY to be taken from this drawing. All dimensions to be checked on site. Any discrepancies to be brought to the aƩenƟon of this office prior to commencement. This drawing is Copyright. This document is the property of Smith & Associates Architects. This document is not to be used, reproduced or circulated without the prior wriƩen permission, in each instance, from Smith & Associates Architects © THIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL OTHER S&AA DRAWINGS Hall Street, Kingscourt, Co. Cavan e: info@saarchitects.ie A82 D1H7 t: (042) 9693700 w: www.saarchitects.ie CLIENT: STAGE: PROJECT: DRAWING TITLE: DRAWING NO:REV: - DATE: SCALE:DWG BY:JOB NO: FI PLANNING PROPOSED GYM FACILITY AND RETENTION OF EXTENSIONS AT LISNAKEENY & CAMAGHY, MAGHERACLOONE, CO. MONAGHAN 1:500 MAY 2026 KM 3450 PROPOSED SITE LAYOUT PLAN MAGHERACLOONE MITCHELLS GAA CLUB PP(00)001 @A1 99.587 1-1 1-1 EXISTING CAR PARKKEEPNETS H=12mKEEPNETS H=12mEXISTING HEDGE SI G H T LI N E 10 0 M RO A D ED G E 3M EXISTI N G HEDG EEXISTING HED GE EXISTING PITCH 68x121.5 m EX I S T I N G BU I L D I N G M A C - F A B SY S T E M PU B L I C RO A D EXIS T I N G DW E L L I N G EXISTING DWELLING EX I S T I N G D W E L L I N G EXI S T I N G D W E L L I N G E X I S T I N G P O U L T R Y H O U S E S E X I S T I N G P O U L T R Y H O U S E S EX I S T I N G FE N C EGOALPOSTSGOALPOSTSFLOOD LIGHTING LINEPROPOSE D GYM FACILITY BUILDING FFL: 99.70 GREEN AREA GREEN AREA PERCOLAT I O N AREA EX I S T I N G EN T R A N C E GREEN AREA EXISTING GRAVEL AREA WWTS EXI S T I N G SU R F A C E W A T E R DR A I N A G E EXISTING ESB POLE EXISTING GRAVEL AREA MH 98.080 98.586 98.317 98.185 97.768 97.525 97.669 97.341 97.186 97.169 96.783 96.632 97.187 97.281 97.388 97.561 98.285 98.031 97.783 98.777 98.990 98.925 99.270 99.371 99.220 99.10099.245 99.274 98.157 98.520 98.442 98.333 97.752 98.155 97.597 97.352 97.517 96.611 97.285 96.812 97.382 96.858 97.170 96.645 97.306 96.896 97.457 97.133 98.436 98.534 98.311 99.818 100.000 99.577 98.653 100.009 100.372 100.399 99.496 99.373 99.360 99.178 99.129 99.321 99.537 99.443 99.506 99.068 98.772 98.026 98.804 97.705 97.765 RIDGE 103.986RI D G E 10 2 . 4 7 8 3.068.07.0 121.5 5.0 5.00 0 . 8 12.7 1.5 22.7 20.410. 4 12.731.06.770.26.712.7 20.043.0 2.2 3.83.43.8 4.413.3PROPOSED GYM FACILITY BUILDING HIGHLIGHTED BLUE LOCATION OF SITE NOTICE EXISTING DRESSING ROOM FACILITY BUILDING WITH AREAS FOR RETENTION HIGHLIGHTED ORANGE. ALL SURFACE WATER DRAINAGE TO BE DIRECTED TO EXISTING SOAKPIT. PROPOSED GYM FACILITY BUILDING STORMWATER TO BE DIRECTED TO EXISTING SOAKPIT PREVIOUSLY GRANTED UNDER PLANNING REF. NO. 18506. EXISTING PERCOLATION AREA & WWTS PREVIOUSLY GRANTED UNDER PLANNING REF. NO. 18506 (NO CHANGES. NOT PART OF THIS APPLICATION) EXISTING SOAKPIT PREVIOUSLY GRANTED UNDER PLANNING REF. NO. 18506 EXISTING EXTERNAL CANOPY TO BE REMOVED. SIG H T LIN E 10 0 M EXISTING DRESSING ROOM FACILITY BUILDING FFL: 99.70 N AREA OUTLINED IN RED INDICATES AREA FOR PLANNING PERMISSION SITE AREA 0.09 ha / 0.21 acre EXISTING STEEL WIRE NET FENCE H=1.8m EXISTING HEDGE STORM WATER SERVICES: FOUL WATER/ WWTS LEGEND AREA FOR RETENTION PROPOSED AREA GRAVEL AREA LANDSCAPING: EXISTING TREE OUTLINE OF EXTERNAL CANOPY STRUCTURE TO BE REMOVED site layout plan 1:500 RECEIVED: 28/05/2026