Loading...
HomeMy WebLinkAbout2660057 - F.I. Received Doc. - Environmental Report Page 1 of 4 Futher Information Response – 26/60057 Client: Magheracloone Mitchells GFC Contact Details: c/o Niall Smith Address: Lisnakeeny & Camaghy, Magheracloone, Co. Monaghan Project Type: Gym Facility Reference No. 2365 Date: 22-05-26 Scope Mitchell Environmental Ltd. have been requested to produce further information for the planning application26/60057 to show that the additional development of the proposed Gym Facility will not affect the loadings on the existing sewage treatment plant and percolation area serving the site. RECEIVED: 28/05/2026 Page 2 of 4 In response to Futher Information 1. (a) Mitchell Environmental has attached site characterisation report carried out by Nevin Traynor of Traynor Environmental Ltd on the 17-10- 2018 in which a proposed 16pe Sewage Treatment Plant and Percolation Area was recommended to serve the site based on the loadings issued. This 16pe Stp and Percolation was installed by Mitchell Environmental (see attached completion report) As the new Gym Facility does not include any new or additional toilet facilities, shower facilities or cooking / eating facility no extra loading will be added to the treatment plant therefore it will not need to be replaced or upgraded. -------------------------------------------------------------------------------------------------------------------------- In response to 1. (b) – see attached Water Protection Plan Checklist -------------------------------------------------------------------------------------------------------------------------- In response to further information 2. (a) I. II. III. IV. As no additional loadings are going to be added to the existing wastewater treatment plant and percolation area with the new proposed Gym Facility. Mitchell Environmental are satisfied that the existing 16PE and Percolation area is fit for purpose and is s ized adequately to deal with the existing loadings. ------------------------------------------------------------------------------------------------------------------------- In response to futher information 2. (b) Discharge will not cause deterioration in water quality on the receiving water body as no additional loadings are being added to the treatment plant, therefore the existing treatment plant and percolation installed is sized adequately to deal with existing loadings. ------------------------------------------------------------------------------------------------------------------------- Yours Sincerely, Gordon Mitchell Director RECEIVED: 28/05/2026 Page 3 of 4 Providing Sustainable and Progressive Environmental Solutions SUDS analysis Flexible Liquid storage Flood Control Solutions Surface Water solutions Hydrocarbon Separation Environmental Solutions Water treatment and control Hydrocarbon Storage Solutions Attenuation/Soakaway Products Specialised Percolation Installations Providing Sustainable and Progressive Sewage Treatment analysis and reports www.mitchellenvironmental.ie Mitchell Environmental Ltd. are fully insured for Public Liability and Private Indemnity. RECEIVED: 28/05/2026 Page 4 of 4 RECEIVED: 28/05/2026