Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2660160 - F.I. Received Doc. - Proposed lighting design
BELL Lighting Design lightingdesign@belllighting.co.uk Page 1/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design Phase 4 Cloghvalley Installation : Proposed Lighting Design Project number : LD8012 Customer : National Electrical Wholesalers, Drogheda Processed by : Glinda Shaji Date : 01.07.2026 Project description: Design based on information provided and aimed to achieve relevant guidelines, shown on results overview page for your verification and approval prior to any orders are placed. We have assumed the following reflection factors and please note any variance to this may affect the lighting level. Warehouse: 20% / 50% / 30% for floor, ceiling and walls/racking respectively Offices : 20% / 70% / 50% for floor, ceiling and walls/racking respectively Refer to the Quantities and Location Schedule for quantities breakdown, luminaire types used within each rooms and assumptions made for each area. Emergency signage allowed utilising types ES/EB wall mounted above fire exit doors internally and externally. The following values are based on precise calculations performed on calibrated lamps and luminaires, and their configurations, whereby gradual, unavoidable deviations can occur in practice. All guarantee claims are excluded for the specified data. This exclusion of liability applies irrespective of the legal grounds for both damages and consequential damages suffered by users and third parties. If dimming or dimmable products used, please make sure all luminaires installed as per the wattage/dimming percentages (or nearest possible) to such specified on results overview page for each area. Please verify usage and target lux levels (specified on results overview page for each area), dimensions, heights and if all areas requiring lighting design are included. Any assumptions made at design stage should be verified prior to placing an order and please do not hesitate to contact us if any alterations or additional details are required. Design concluded assuming no obstruction to lighting or light fittings other than specified on plans/information provided. Luminaire spacings shown are indicative only and not to be used for installation purposes. Please contact us if accurate installation plans are required prior to placing any orders. Any additional luminaires for the above will be subject to an additional cost. The emergency lighting design has been prepared by the Designer acting as a competent person in accordance with the information made available at the time of design. The design has been developed with reference to BS 5266 1:2016 + A1:2020 and BS EN 1838, based on the assumed escape routes, occupancy and operational use as advised by the Client or Responsible Person, however no allowance has been made (unless specified) for any high risk areas or any additional specific points of emphasis or minimum 2 fittings in each area, which may require additional emergency luminaires. The Designer’s role is limited to providing a technical lighting design and associated calculations. The Designer does not act as the Responsible Person as defined under the Regulatory Reform (Fire Safety) Order 2005, nor does the Designer undertake or validate the Fire Risk Assessment. Emergency exit signs allowed assuming clear line of sight, with the appropriate viewing distances for the product. If this line of sight is obstructed and/or the viewing distances exceeded, then additional signage may be required.RECEIVED: 20/07/2026 Description, Ground Floor x2nos 0.xx Floor 3D Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 2/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design RECEIVED: 20/07/2026 Description, Ground Floor x2nos 0.xx Floor plan Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 3/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design RECEIVED: 20/07/2026 0.01 Unit 6(b) Description, 0.01 Unit 6(b) Floor plan Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 4/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design -0 2 4 6 8 10 12 14 16 18 x [m] -0 2 4 6 8 10 12 y [m] 18.5515.909.604.303.300.17 9.30 5.79 3.10 0.14 Room data: Reflectance: W1 : W2 : W3 : W4 : W5 : W6 : Floor: Ceiling: Room height [m]: Height of ref. plane [m]: 12.50 30.0 % 6.40 30.0 % 6.40 30.0 % 6.40 30.0 % ----- ----- ----- ----- ----- ----- 20.0 % 50.0 % 7.20 0.00 RECEIVED: 20/07/2026 0.01 Unit 6(b) Summary, 0.01 Unit 6(b) Result overview, Evaluation area 1 Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 5/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design -0 2 4 6 8 10 12 14 16 18 x [m] 18.5515.909.604.300.17 9.30 5.79 3.10 0.14 Boundary line at 300 lx 200 300 Illuminance [lx] General Calculation algorithm used Average indirect fraction Maintenance factor 0.80 Total lamp luminous flux 173736.00 lm Luminaire luminous flux 173735.83 lm Total power 1200.0 W Total power per area (240.12 m²)5.00 W/m² (1.28 W/m²/100lx) Evaluation area 1 Reference plane 1.1 Horizontal cylindrical E̅m 390 lx 156 lx Emin 252 lx 115 lx Emin/E̅m (Uo)0.65 0.73 Emin/Emax (Ud)0.52 Ez/Eh 0.34 Position 0.00 m 1.60 m Major surfaces E̅m Uo Type No.\Make BELL Lighting Limited 1 6 x Order No. : !A 11454 Luminaire name : Atlas 120W-200W 4000K 120º High Bay IP65 Equipment : 1 x LED 4000K 200 W / 28956 lm RECEIVED: 20/07/2026 0.01 Unit 6(b) Summary, 0.01 Unit 6(b) Result overview (emergency lighting) Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 6/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design -0 2 4 6 8 10 12 14 16 18 x [m] 18.5515.909.604.300.17 9.30 5.79 3.10 0.14 0 0.5 1 5 10 15 20 30 50 75 100 200 300 500 750 1000 1500 2000 3000 5000 Illuminance [lx] General Calculation algorithm used : Direct component Maintenance factor : 0.8 Height (phot.centre)-variable- Maximum I : 390 cd Anti panic area: Surface No.Emin [lx]Emax [lx]Ud Anti panic area 1.1 Calculation field: 11.5m x 18.21m (8 x 12 pts), Height = 0.00m 1 0.83 lx 7.35 lx 1: 8.83 >= 0.5 lx >= 1 : 40 Type No.\Make BELL Lighting Limited 8 2E x Order No. : !EM1 09094V2 -- Emergency Lighting -- Luminaire name : Spectrum Pro 7W Emergency Bulkhead IP65 Equipment : 1 x LED 6500K EM 9 W / 1094 lm (0%) Emergency : 1094 lm Maintenance factor: 0.80 RECEIVED: 20/07/2026 0.01 Unit 6(b) Summary, 0.01 Unit 6(b) Result overview (emergency lighting) Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 7/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 11 2E x Order No.: !ES 09066V2 -- Emergency Lighting -- Luminaire name : Spectrum 2.5W Emergency 6 in 1 Exit Blade (Up Legend) Equipment : 1 x LED 6500K EM 2 W / 19 lm (0%) Emergency : 19 lm Maintenance factor: 0.80 12 2E x Order No.: !EB 09040V2 -- Emergency Lighting -- Luminaire name : Spectrum 3.3W Emergency Bulkhead IP65 Equipment : 1 x LED 6500K EM 3.3 W / 187 lm (0%) Emergency : 187 lm Maintenance factor: 0.80 RECEIVED: 20/07/2026 0.02 Entrance + Stairs Description, 0.02 Entrance + Stairs Floor plan Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 8/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design -1.4 -0.9 -0.4 0.1 0.6 1.1 1.6 2.1 x [m] -0 1 2 3 4 5 6 y [m] 2.701.961.000.40 5.60 5.00 3.20 2.86 1.40 0.80 0.16 -0.23 Wall x y Length Area[m²] Reflectance 1 25.70 m 0.00 m 2.70 m 8.10 50.0 % 2 25.70 m 6.07 m 6.07 m 18.21 50.0 % 3 24.47 m 6.07 m 1.23 m 3.68 50.0 % 4 24.47 m 6.60 m 0.53 m 1.59 50.0 % 5 21.62 m 6.60 m 2.85 m 8.55 50.0 % 6 21.62 m 4.00 m 2.60 m 7.80 50.0 % 7 23.00 m 4.00 m 1.38 m 4.13 50.0 % 8 23.00 m 0.00 m 4.00 m 12.00 50.0 % Floor: 20.7 20.0 % Ceiling: 20.7 70.0 % Room height [m]: 3.00 m Height of ref. plane [m]: 0.00 m Volume 62.2 m³RECEIVED: 20/07/2026 0.02 Entrance + Stairs Summary, 0.02 Entrance + Stairs Result overview, Evaluation area 1 Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 9/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design -1.4 -0.4 0.6 1.6 x [m] 2.701.00 5.60 5.00 3.20 1.40 0.80 0.16 Boundary line at 200 lx 100 200 Illuminance [lx] General Calculation algorithm used Average indirect fraction Maintenance factor 0.80 Luminaire luminous flux 8920.00 lm Total power 60.0 W Total power per area (20.74 m²)2.89 W/m² (1.70 W/m²/100lx) Evaluation area 1 Reference plane 1.1 Usage profile Entrance halls 36.1 (EN 12464-1, 11.2021) (Ra >80.00) Horizontal cylindrical E̅m 170 lx (>= 150 lx)148 lx (>= 75 lx) Emin 125 lx 96 lx Emin/E̅m (Uo)0.74 (>= 0.40)0.65 (>= 0.10) Emin/Emax (Ud)0.60 Ez/Eh 0.53 Position 0.00 m 1.60 m Major surfaces E̅m Uo Type No.\Make RECEIVED: 20/07/2026 0.02 Entrance + Stairs Summary, 0.02 Entrance + Stairs Result overview, Evaluation area 1 Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 10/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design BELL Lighting Limited 2 3 x Order No.: !B 06830 Luminaire name : Deco Slim 12W CCT Bulkhead IP54 Equipment : 1 x LED 4000K 12 W / 1784 lm 4 2E x Order No.: !BE 06833 -- Emergency Lighting -- Luminaire name : Deco Slim 12W CCT Bulkhead IP54 Emergency Equipment : 1 x LED 4000K 12 W / 1784 lm Emergency : 105 lm (5.9 %)RECEIVED: 20/07/2026 0.02 Entrance + Stairs Summary, 0.02 Entrance + Stairs Result overview (emergency lighting) Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 11/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design -1.4 -0.4 0.6 1.6 x [m] 2.701.00 5.60 5.00 3.20 1.40 0.80 0.16 0 0.5 1 5 10 15 20 30 50 75 100 200 300 500 750 1000 1500 2000 3000 5000 Illuminance [lx] General Calculation algorithm used : Direct component Maintenance factor : 0.8 Height (phot.centre)-variable- Maximum I : 250 cd Anti panic area: Surface No.Emin [lx]Emax [lx]Ud Anti panic area 1.1 Calculation field: 3.68m x 6.3m (6 x 9 pts), Height = 0.00m 1 1.87 lx 7.70 lx 1: 4.12 >= 1 lx >= 1 : 40 Type No.\Make BELL Lighting Limited 4 2E x Order No. : !BE 06833 -- Emergency Lighting -- Luminaire name : Deco Slim 12W CCT Bulkhead IP54 Emergency Equipment : 1 x LED 4000K 12 W / 1784 lm Emergency : 105 lm (5.9 %) Maintenance factor: 0.80 RECEIVED: 20/07/2026 0.02 Entrance + Stairs Summary, 0.02 Entrance + Stairs Result overview (emergency lighting) Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 12/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 10 2E x Order No.: !EM3 09126 -- Emergency Lighting -- Luminaire name : Spectrum 2W Corridor 4 in 1 Emergency Downlight Equipment : 1 x LED 6500K EM 1.2 W / 171 lm (0%) Emergency : 171 lm Maintenance factor: 0.80 11 1E x Order No.: !ES 09066V2 -- Emergency Lighting -- Luminaire name : Spectrum 2.5W Emergency 6 in 1 Exit Blade (Up Legend) Equipment : 1 x LED 6500K EM 2 W / 19 lm (0%) Emergency : 19 lm Maintenance factor: 0.80 12 1E x Order No.: !EB 09040V2 -- Emergency Lighting -- Luminaire name : Spectrum 3.3W Emergency Bulkhead IP65 Equipment : 1 x LED 6500K EM 3.3 W / 187 lm (0%) Emergency : 187 lm Maintenance factor: 0.80 RECEIVED: 20/07/2026 0.03 Reception Description, 0.03 Reception Floor plan Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 13/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 x [m] -0.03 0.22 0.47 0.72 0.97 1.22 1.47 1.72 1.97 2.22 2.47 2.72 y [m] 2.702.100.90 1.30 Wall x y Length Area[m²] Reflectance 1 22.90 m 0.00 m 3.60 m 10.79 50.0 % 2 22.90 m 2.80 m 2.80 m 8.40 50.0 % 3 19.30 m 2.80 m 3.60 m 10.79 50.0 % 4 19.30 m 0.00 m 2.80 m 8.40 50.0 % Floor: 10.1 20.0 % Ceiling: 10.1 70.0 % Room height [m]: 3.00 m Height of ref. plane [m]: 0.00 m Volume 30.2 m³RECEIVED: 20/07/2026 0.03 Reception Summary, 0.03 Reception Result overview, Evaluation area 1 Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 14/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 x [m] 2.702.100.90 1.30 Boundary line at 300 lx 200 300 Illuminance [lx] General Calculation algorithm used Average indirect fraction Height of luminaire plane 3.00 m Maintenance factor 0.80 Luminaire luminous flux 5966.00 lm Total power 40.0 W Total power per area (10.07 m²)3.97 W/m² (1.61 W/m²/100lx) Evaluation area 1 Reference plane 1.1 Usage profile Entrance halls 44.18 (EN 12464-1, 11.2021) (Ra >80.00) Reception Horizontal cylindrical E̅m 247 lx (>= 200 lx)139 lx (>= 75 lx) Emin 211 lx 111 lx Emin/E̅m (Uo)0.86 (>= 0.40)0.80 (>= 0.10) Emin/Emax (Ud)0.77 Ez/Eh 0.28 Position 0.00 m 1.60 m Major surfaces E̅m Uo Type No.\Make RECEIVED: 20/07/2026 0.03 Reception Summary, 0.03 Reception Result overview, Evaluation area 1 Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 15/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design BELL Lighting Limited 6 2 x Order No.: !C 11748 Luminaire name : Arial Multi 4000K 600x600 UGR19 Panel Equipment : 1 x LED 4000K 20 W / 2983 lm RECEIVED: 20/07/2026 Summary, 0.03 Reception Result overview, 0.03 Reception Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 16/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 1 Horizontal illuminance Measuring surface X Y Z E Reception Desk 20.80 m 1.78 m 0.75 m 360.97 lx RECEIVED: 20/07/2026 0.03 Reception Summary, 0.03 Reception Result overview (emergency lighting) Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 17/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 x [m] 2.702.100.90 1.30 0 0.5 1 5 10 15 20 30 50 75 100 200 300 500 750 1000 1500 2000 3000 5000 Illuminance [lx] General Calculation algorithm used : Direct component Maintenance factor : 0.8 Height (phot.centre): 2.97 m Maximum I : 93 cd <= 900 cd Anti panic area: Surface No.Emin [lx]Emax [lx]Ud Anti panic area 1.1 Calculation field: 2.76m x 1.96m (7 x 5 pts), Height = 0.00m 1 1.03 lx 1.51 lx 1: 1.46 >= 0.5 lx >= 1 : 40 Type No.\Make BELL Lighting Limited 9 1E x Order No. : !EM2 09126 -- Emergency Lighting -- Luminaire name : Spectrum 2W Open Area 4 in 1 Emergency Downlight Equipment : 1 x LED 6500K EM 1.2 W / 175 lm (0%) Emergency : 175 lm Maintenance factor: 0.80 RECEIVED: 20/07/2026 0.04 Comms Description, 0.04 Comms Floor plan Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 18/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 0.0 0.2 0.4 0.6 0.8 1.0 1.2 x [m] 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 y [m] 0.64 0.50 Wall x y Length Area[m²] Reflectance 1 22.90 m 2.90 m 1.28 m 3.83 50.0 % 2 22.90 m 3.90 m 1.00 m 3.00 50.0 % 3 21.62 m 3.90 m 1.28 m 3.83 50.0 % 4 21.62 m 2.90 m 1.00 m 3.00 50.0 % Floor: 1.3 20.0 % Ceiling: 1.3 70.0 % Room height [m]: 3.00 m Height of ref. plane [m]: 0.00 m Volume 3.8 m³RECEIVED: 20/07/2026 0.04 Comms Summary, 0.04 Comms Result overview, Evaluation area 1 Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 19/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 0.0 0.2 0.4 0.6 0.8 1.0 1.2 x [m] 0.64 0.50 Boundary line at 300 lx 200 300 Illuminance [lx] General Calculation algorithm used Average indirect fraction Height of luminaire plane 3.00 m Maintenance factor 0.80 Luminaire luminous flux 3851.00 lm Total power 26.0 W Total power per area (1.28 m²)20.39 W/m² (8.37 W/m²/100lx) Evaluation area 1 Reference plane 1.1 Usage profile Plant rooms, switch gear rooms 11.1 (EN 12464-1, 11.2021) (Ra >80.00) Horizontal cylindrical E̅m 244 lx (>= 200 lx)232 lx (>= 50 lx) Emin 235 lx 218 lx Emin/E̅m (Uo)0.97 (>= 0.40)0.94 (>= 0.10) Emin/Emax (Ud)0.93 Ez/Eh 0.25 Position 0.00 m 1.60 m Type No.\Make BELL Lighting Limited 7 1 x Order No. : !C1 11748 Luminaire name : Arial Multi 4000K 600x600 UGR19 Panel Equipment : 1 x LED 4000K 26 W / 3851 lm RECEIVED: 20/07/2026 0.05 WC Description, 0.05 WC Floor plan Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 20/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 x [m] 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 y [m] 1.20 0.50 Wall x y Length Area[m²] Reflectance 1 21.52 m 2.90 m 2.31 m 6.92 50.0 % 2 21.52 m 3.90 m 1.00 m 3.00 50.0 % 3 19.21 m 3.90 m 2.31 m 6.92 50.0 % 4 19.21 m 2.90 m 1.00 m 3.00 50.0 % Floor: 2.3 20.0 % Ceiling: 2.3 70.0 % Room height [m]: 3.00 m Height of ref. plane [m]: 0.75 m Volume 6.9 m³RECEIVED: 20/07/2026 0.05 WC Summary, 0.05 WC Result overview, Evaluation area 1 Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 21/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 x [m] 1.20 0.50 Boundary line at 200 lx 100 200 Illuminance [lx] General Calculation algorithm used Average indirect fraction Height of luminaire plane 3.00 m Maintenance factor 0.80 Luminaire luminous flux 2676.00 lm Total power 18.0 W Total power per area (2.30 m²)7.81 W/m² (3.90 W/m²/100lx) Evaluation area 1 Reference plane 1.1 Usage profile Cloakroom (area), washrooms, bathrooms, dressing-, lockers-, shower-, sink- and toilet areas 10.4 (EN 12464-1, 11.2021) (Ra >80.00) Horizontal cylindrical E̅m 200 lx (>= 200 lx)91 lx (>= 75 lx) Emin 163 lx 72 lx Emin/E̅m (Uo)0.81 (>= 0.40)0.79 (>= 0.10) Emin/Emax (Ud)0.72 Ez/Eh 0.27 Position 0.75 m 1.40 m Type No.\Make RECEIVED: 20/07/2026 0.05 WC Summary, 0.05 WC Result overview, Evaluation area 1 Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 22/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design BELL Lighting Limited 3 1 x Order No.: !B1 06831 Luminaire name : Deco Slim 18W CCT Bulkhead IP54 Equipment : 1 x LED 4000K 18 W / 2676 lm RECEIVED: 20/07/2026 0.06 Ladies / Acc WC Description, 0.06 Ladies / Acc WC Floor plan Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 23/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 x [m] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 y [m] 1.601.10 0.70 Wall x y Length Area[m²] Reflectance 1 21.52 m 4.00 m 2.20 m 6.60 50.0 % 2 21.52 m 5.50 m 1.50 m 4.50 50.0 % 3 19.32 m 5.50 m 2.20 m 6.60 50.0 % 4 19.32 m 4.00 m 1.50 m 4.50 50.0 % Floor: 3.3 20.0 % Ceiling: 3.3 70.0 % Room height [m]: 3.00 m Height of ref. plane [m]: 0.75 m Volume 9.9 m³RECEIVED: 20/07/2026 0.06 Ladies / Acc WC Summary, 0.06 Ladies / Acc WC Result overview, Evaluation area 1 Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 24/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 x [m] 1.601.10 0.70 Boundary line at 200 lx 100 200 Illuminance [lx] General Calculation algorithm used Average indirect fraction Height of luminaire plane 3.00 m Maintenance factor 0.80 Luminaire luminous flux 2676.00 lm Total power 18.0 W Total power per area (3.30 m²)5.46 W/m² (2.73 W/m²/100lx) Evaluation area 1 Reference plane 1.1 Usage profile Cloakroom (area), washrooms, bathrooms, dressing-, lockers-, shower-, sink- and toilet areas 10.4 (EN 12464-1, 11.2021) (Ra >80.00) Horizontal cylindrical E̅m 200 lx (>= 200 lx)91 lx (>= 75 lx) Emin 178 lx 78 lx Emin/E̅m (Uo)0.89 (>= 0.40)0.86 (>= 0.10) Emin/Emax (Ud)0.81 Ez/Eh 0.29 Position 0.75 m 1.40 m Major surfaces E̅m Uo Type No.\Make RECEIVED: 20/07/2026 0.06 Ladies / Acc WC Summary, 0.06 Ladies / Acc WC Result overview, Evaluation area 1 Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 25/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design BELL Lighting Limited 3 1 x Order No.: !B1 06831 Luminaire name : Deco Slim 18W CCT Bulkhead IP54 Equipment : 1 x LED 4000K 18 W / 2676 lm RECEIVED: 20/07/2026 0.06 Ladies / Acc WC Summary, 0.06 Ladies / Acc WC Result overview (emergency lighting) Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 26/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 x [m] 1.601.10 0.70 0 0.5 1 5 10 15 20 30 50 75 100 200 300 500 750 1000 1500 2000 3000 5000 Illuminance [lx] General Calculation algorithm used : Direct component Maintenance factor : 0.8 Height (phot.centre): 2.97 m Maximum I : 93 cd <= 900 cd Anti panic area: Surface No.Emin [lx]Emax [lx]Ud Anti panic area 1.1 Calculation field: 1.75m x 1.05m (6 x 4 pts), Height = 0.00m 1 1.18 lx 1.50 lx 1: 1.27 >= 1 lx >= 1 : 40 Type No.\Make BELL Lighting Limited 9 1E x Order No. : !EM2 09126 -- Emergency Lighting -- Luminaire name : Spectrum 2W Open Area 4 in 1 Emergency Downlight Equipment : 1 x LED 6500K EM 1.2 W / 175 lm (0%) Emergency : 175 lm Maintenance factor: 0.80 RECEIVED: 20/07/2026 0.07 WC Description, 0.07 WC Floor plan Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 27/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 x [m] 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 y [m] 1.10 0.50 Wall x y Length Area[m²] Reflectance 1 21.52 m 5.60 m 2.20 m 6.60 50.0 % 2 21.52 m 6.60 m 1.00 m 3.00 50.0 % 3 19.32 m 6.60 m 2.20 m 6.60 50.0 % 4 19.32 m 5.60 m 1.00 m 3.00 50.0 % Floor: 2.2 20.0 % Ceiling: 2.2 70.0 % Room height [m]: 3.00 m Height of ref. plane [m]: 0.75 m Volume 6.6 m³RECEIVED: 20/07/2026 0.07 WC Summary, 0.07 WC Result overview, Evaluation area 1 Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 28/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 x [m] 1.10 0.50 Boundary line at 200 lx 100 200 Illuminance [lx] General Calculation algorithm used Average indirect fraction Height of luminaire plane 3.00 m Maintenance factor 0.80 Luminaire luminous flux 2676.00 lm Total power 18.0 W Total power per area (2.20 m²)8.19 W/m² (4.02 W/m²/100lx) Evaluation area 1 Reference plane 1.1 Usage profile Cloakroom (area), washrooms, bathrooms, dressing-, lockers-, shower-, sink- and toilet areas 10.4 (EN 12464-1, 11.2021) (Ra >80.00) Horizontal cylindrical E̅m 204 lx (>= 200 lx)92 lx (>= 75 lx) Emin 169 lx 77 lx Emin/E̅m (Uo)0.83 (>= 0.40)0.84 (>= 0.10) Emin/Emax (Ud)0.75 Ez/Eh 0.27 Position 0.75 m 1.40 m Type No.\Make RECEIVED: 20/07/2026 0.07 WC Summary, 0.07 WC Result overview, Evaluation area 1 Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 29/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design BELL Lighting Limited 3 1 x Order No.: !B1 06831 Luminaire name : Deco Slim 18W CCT Bulkhead IP54 Equipment : 1 x LED 4000K 18 W / 2676 lm RECEIVED: 20/07/2026 0.08 Office Description, 0.08 Office Floor plan Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 30/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 x [m] -0.5 -0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 y [m] 5.003.803.201.40 4.70 2.90 1.10 Wall x y Length Area[m²] Reflectance 1 24.60 m 6.70 m 5.28 m 15.83 50.0 % 2 24.60 m 6.17 m 0.53 m 1.58 50.0 % 3 25.70 m 6.17 m 1.10 m 3.30 50.0 % 4 25.70 m 12.50 m 6.33 m 18.98 50.0 % 5 19.32 m 12.50 m 6.38 m 19.13 50.0 % 6 19.32 m 6.70 m 5.80 m 17.40 50.0 % Floor: 37.6 20.0 % Ceiling: 37.6 70.0 % Room height [m]: 3.00 m Height of ref. plane [m]: 0.75 m Volume 112.7 m³RECEIVED: 20/07/2026 0.08 Office Summary, 0.08 Office Result overview, Evaluation area 1 Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 31/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 0.0 1.0 2.0 3.0 4.0 5.0 6.0 x [m] 5.003.801.40 4.70 2.90 1.10 Boundary line at 500 lx 300 500 Illuminance [lx] General Calculation algorithm used Average indirect fraction Height of luminaire plane 3.00 m Maintenance factor 0.80 Luminaire luminous flux 26847.00 lm Total power 180.0 W Total power per area (37.57 m²)4.79 W/m² (0.87 W/m²/100lx) Evaluation area 1 Reference plane 1.1 Usage profile Writing, typing, reading, data processing 34.2 (EN 12464-1, 11.2021) (Ra >80.00) Horizontal cylindrical E̅m 552 lx (>= 500 lx)198 lx (>= 150 lx) Emin 363 lx 144 lx Emin/E̅m (Uo)0.66 (>= 0.60)0.73 (>= 0.10) Emin/Emax (Ud)0.53 Ez/Eh 0.33 Position 0.75 m 1.20 m Major surfaces E̅m Uo Type No.\Make RECEIVED: 20/07/2026 0.08 Office Summary, 0.08 Office Result overview, Evaluation area 1 Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 32/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design BELL Lighting Limited 6 9 x Order No.: !C 11748 Luminaire name : Arial Multi 4000K 600x600 UGR19 Panel Equipment : 1 x LED 4000K 20 W / 2983 lm RECEIVED: 20/07/2026 0.08 Office Summary, 0.08 Office Result overview (emergency lighting) Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 33/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 0.0 1.0 2.0 3.0 4.0 5.0 6.0 x [m] 5.003.801.40 4.70 2.90 1.10 0 0.5 1 5 10 15 20 30 50 75 100 200 300 500 750 1000 1500 2000 3000 5000 Illuminance [lx] General Calculation algorithm used : Direct component Maintenance factor : 0.8 Height (phot.centre): 2.97 m Maximum I : 93 cd <= 900 cd Anti panic area: Surface No.Emin [lx]Emax [lx]Ud Anti panic area 1.1 Calculation field: 5.38m x 5.33m (9 x 9 pts), Height = 0.00m 1 0.60 lx 1.52 lx 1: 2.52 >= 0.5 lx >= 1 : 40 Type No.\Make BELL Lighting Limited 9 1E x Order No. : !EM2 09126 -- Emergency Lighting -- Luminaire name : Spectrum 2W Open Area 4 in 1 Emergency Downlight Equipment : 1 x LED 6500K EM 1.2 W / 175 lm (0%) Emergency : 175 lm Maintenance factor: 0.80 RECEIVED: 20/07/2026 Description, First Floor x2nos 1.xx Floor 3D Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 34/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design RECEIVED: 20/07/2026 Description, First Floor x2nos 1.xx Floor plan Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 35/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design RECEIVED: 20/07/2026 1.01 Landing Description, 1.01 Landing Floor plan Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 36/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 x [m] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 y [m] 4.793.291.581.08 1.87 1.19 0.62 Wall x y Length Area[m²] Reflectance 1 6.49 m 6.60 m 5.28 m 15.84 50.0 % 2 6.49 m 7.80 m 1.20 m 3.60 50.0 % 3 3.39 m 7.80 m 3.10 m 9.30 50.0 % 4 3.39 m 9.10 m 1.30 m 3.90 50.0 % 5 1.21 m 9.10 m 2.18 m 6.53 50.0 % 6 1.21 m 6.60 m 2.50 m 7.50 50.0 % Floor: 9.2 20.0 % Ceiling: 9.2 70.0 % Room height [m]: 3.00 m Height of ref. plane [m]: 0.00 m Volume 27.5 m³RECEIVED: 20/07/2026 1.01 Landing Summary, 1.01 Landing Result overview, Evaluation area 1 Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 37/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 x [m] 4.793.291.581.08 1.87 1.19 0.62 Boundary line at 200 lx 100 200 Illuminance [lx] General Calculation algorithm used Average indirect fraction Maintenance factor 0.80 Luminaire luminous flux 10704.00 lm Total power 72.0 W Total power per area (9.17 m²)7.86 W/m² (3.60 W/m²/100lx) Evaluation area 1 Reference plane 1.1 Usage profile Stairs, escalators, travolators 9.2 (EN 12464-1, 11.2021) (Ra >40.00) Horizontal cylindrical E̅m 218 lx (>= 150 lx)256 lx (>= 75 lx) Emin 133 lx 150 lx Emin/E̅m (Uo)0.61 (>= 0.40)0.59 (>= 0.10) Emin/Emax (Ud)0.52 Ez/Eh 0.45 Position 0.00 m 1.60 m Major surfaces E̅m Uo Type No.\Make RECEIVED: 20/07/2026 1.01 Landing Summary, 1.01 Landing Result overview, Evaluation area 1 Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 38/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design BELL Lighting Limited 3 2 x Order No.: !B1 06831 Luminaire name : Deco Slim 18W CCT Bulkhead IP54 Equipment : 1 x LED 4000K 18 W / 2676 lm 5 2 x Order No.: !B1E 06834 Luminaire name : Deco Slim 18W CCT Bulkhead IP54 Emergency Equipment : 1 x LED 4000K 18 W / 2676 lm Emergency : 105 lm (3.9 %)RECEIVED: 20/07/2026 1.01 Landing Summary, 1.01 Landing Result overview (emergency lighting) Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 39/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 x [m] 4.793.291.581.08 1.87 1.19 0.62 0 0.5 1 5 10 15 20 30 50 75 100 200 300 500 750 1000 1500 2000 3000 5000 Illuminance [lx] General Calculation algorithm used : Direct component Maintenance factor : 0.8 Height (phot.centre): 2.97 m Maximum I : 93 cd <= 900 cd Anti panic area: Surface No.Emin [lx]Emax [lx]Ud Anti panic area 1.1 Calculation field: 4.92m x 2.14m (17 x 7 pts), Height = 0.00m 1 0.70 lx 1.51 lx 1: 2.17 >= 0.5 lx >= 1 : 40 Type No.\Make BELL Lighting Limited 9 1E x Order No. : !EM2 09126 -- Emergency Lighting -- Luminaire name : Spectrum 2W Open Area 4 in 1 Emergency Downlight Equipment : 1 x LED 6500K EM 1.2 W / 175 lm (0%) Emergency : 175 lm Maintenance factor: 0.80 RECEIVED: 20/07/2026 1.02 Office Description, 1.02 Office Floor plan Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 40/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 x [m] 0 1 2 3 4 5 6 y [m] 5.603.801.40 5.60 3.20 2.60 1.40 0.80 Wall x y Length Area[m²] Reflectance 1 6.49 m 0.00 m 6.38 m 19.13 50.0 % 2 6.49 m 2.62 m 2.62 m 7.87 50.0 % 3 5.19 m 2.62 m 1.30 m 3.91 50.0 % 4 5.19 m 6.50 m 3.88 m 11.63 50.0 % 5 0.11 m 6.50 m 5.08 m 15.23 50.0 % 6 0.11 m 0.00 m 6.50 m 19.50 50.0 % Floor: 36.4 20.0 % Ceiling: 36.4 70.0 % Room height [m]: 3.00 m Height of ref. plane [m]: 0.75 m Volume 109.2 m³RECEIVED: 20/07/2026 1.02 Office Summary, 1.02 Office Result overview, Evaluation area 1 Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 41/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 0.0 1.0 2.0 3.0 4.0 5.0 6.0 x [m] 5.603.801.40 5.60 3.20 2.60 1.40 0.80 Boundary line at 500 lx 300 500 Illuminance [lx] General Calculation algorithm used Average indirect fraction Height of luminaire plane 3.00 m Maintenance factor 0.80 Luminaire luminous flux 26957.00 lm Total power 182.0 W Total power per area (36.42 m²)5.00 W/m² (1.00 W/m²/100lx) Evaluation area 1 Reference plane 1.1 Usage profile Writing, typing, reading, data processing 34.2 (EN 12464-1, 11.2021) (Ra >80.00) Horizontal cylindrical E̅m 502 lx (>= 500 lx)188 lx (>= 150 lx) Emin 393 lx 139 lx Emin/E̅m (Uo)0.78 (>= 0.60)0.74 (>= 0.10) Emin/Emax (Ud)0.66 Ez/Eh 0.34 Position 0.75 m 1.20 m Major surfaces E̅m Uo Type No.\Make RECEIVED: 20/07/2026 1.02 Office Summary, 1.02 Office Result overview, Evaluation area 1 Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 42/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design BELL Lighting Limited 7 7 x Order No.: !C1 11748 Luminaire name : Arial Multi 4000K 600x600 UGR19 Panel Equipment : 1 x LED 4000K 26 W / 3851 lm RECEIVED: 20/07/2026 1.02 Office Summary, 1.02 Office Result overview (emergency lighting) Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 43/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 0.0 1.0 2.0 3.0 4.0 5.0 6.0 x [m] 5.603.801.40 5.60 3.20 2.60 1.40 0.80 0 0.5 1 5 10 15 20 30 50 75 100 200 300 500 750 1000 1500 2000 3000 5000 Illuminance [lx] General Calculation algorithm used : Direct component Maintenance factor : 0.8 Height (phot.centre): 2.97 m Maximum I : 93 cd <= 900 cd Anti panic area: Surface No.Emin [lx]Emax [lx]Ud Anti panic area 1.1 Calculation field: 5.38m x 5.5m (9 x 9 pts), Height = 0.00m 1 0.55 lx 1.52 lx 1: 2.76 >= 0.5 lx >= 1 : 40 Type No.\Make BELL Lighting Limited 9 1E x Order No. : !EM2 09126 -- Emergency Lighting -- Luminaire name : Spectrum 2W Open Area 4 in 1 Emergency Downlight Equipment : 1 x LED 6500K EM 1.2 W / 175 lm (0%) Emergency : 175 lm Maintenance factor: 0.80 RECEIVED: 20/07/2026 1.03 WC Description, 1.03 WC Floor plan Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 44/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 0.0 0.2 0.4 0.6 0.8 1.0 x [m] 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 y [m] 0.50 1.20 Wall x y Length Area[m²] Reflectance 1 1.11 m 6.60 m 1.00 m 3.00 50.0 % 2 1.11 m 9.10 m 2.50 m 7.50 50.0 % 3 0.11 m 9.10 m 1.00 m 3.00 50.0 % 4 0.11 m 6.60 m 2.50 m 7.50 50.0 % Floor: 2.5 20.0 % Ceiling: 2.5 70.0 % Room height [m]: 3.00 m Height of ref. plane [m]: 0.75 m Volume 7.5 m³RECEIVED: 20/07/2026 1.03 WC Summary, 1.03 WC Result overview, Evaluation area 1 Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 45/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 0.0 0.3 0.6 0.9 x [m] 0.50 1.20 Boundary line at 200 lx 100 200 Illuminance [lx] General Calculation algorithm used Average indirect fraction Height of luminaire plane 3.00 m Maintenance factor 0.80 Luminaire luminous flux 2676.00 lm Total power 18.0 W Total power per area (2.50 m²)7.19 W/m² (3.73 W/m²/100lx) Evaluation area 1 Reference plane 1.1 Usage profile Cloakroom (area), washrooms, bathrooms, dressing-, lockers-, shower-, sink- and toilet areas 10.4 (EN 12464-1, 11.2021) (Ra >80.00) Horizontal cylindrical E̅m 193 lx (>= 200 lx)88 lx (>= 75 lx) Emin 148 lx 71 lx Emin/E̅m (Uo)0.77 (>= 0.40)0.81 (>= 0.10) Emin/Emax (Ud)0.67 Ez/Eh 0.28 Position 0.75 m 1.40 m Type No.\Make RECEIVED: 20/07/2026 1.03 WC Summary, 1.03 WC Result overview, Evaluation area 1 Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 46/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design BELL Lighting Limited 3 1 x Order No.: !B1 06831 Luminaire name : Deco Slim 18W CCT Bulkhead IP54 Equipment : 1 x LED 4000K 18 W / 2676 lm RECEIVED: 20/07/2026 1.04 Meeting Room Description, 1.04 Meeting Room Floor plan Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 47/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 0.00 0.50 1.00 1.50 2.00 2.50 3.00 x [m] 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 y [m] 1.50 3.50 2.30 1.70 1.10 Wall x y Length Area[m²] Reflectance 1 6.49 m 7.90 m 3.00 m 9.00 50.0 % 2 6.49 m 12.50 m 4.60 m 13.80 50.0 % 3 3.49 m 12.50 m 3.00 m 9.00 50.0 % 4 3.49 m 7.90 m 4.60 m 13.80 50.0 % Floor: 13.8 20.0 % Ceiling: 13.8 70.0 % Room height [m]: 3.00 m Height of ref. plane [m]: 0.75 m Volume 41.4 m³RECEIVED: 20/07/2026 1.04 Meeting Room Summary, 1.04 Meeting Room Result overview, Evaluation area 1 Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 48/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 0.00 0.75 1.50 2.25 3.00 x [m] 1.50 3.50 2.30 1.70 1.10 Boundary line at 500 lx 300 500 Illuminance [lx] General Calculation algorithm used Average indirect fraction Height of luminaire plane 3.00 m Maintenance factor 0.80 Luminaire luminous flux 11553.00 lm Total power 78.0 W Total power per area (13.80 m²)5.65 W/m² (1.02 W/m²/100lx) Evaluation area 1 Reference plane 1.1 Usage profile Conference and meeting rooms 34.5.1 (EN 12464-1, 11.2021) (Ra >80.00) Horizontal cylindrical E̅m 553 lx (>= 500 lx)204 lx (>= 150 lx) Emin 397 lx 174 lx Emin/E̅m (Uo)0.72 (>= 0.60)0.85 (>= 0.10) Emin/Emax (Ud)0.56 Ez/Eh 0.28 Position 0.75 m 1.40 m Major surfaces E̅m Uo Type No.\Make RECEIVED: 20/07/2026 1.04 Meeting Room Summary, 1.04 Meeting Room Result overview, Evaluation area 1 Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 49/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design BELL Lighting Limited 7 3 x Order No.: !C1 11748 Luminaire name : Arial Multi 4000K 600x600 UGR19 Panel Equipment : 1 x LED 4000K 26 W / 3851 lm RECEIVED: 20/07/2026 1.04 Meeting Room Summary, 1.04 Meeting Room Result overview (emergency lighting) Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 50/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 0.00 0.75 1.50 2.25 3.00 x [m] 1.50 3.50 2.30 1.70 1.10 0 0.5 1 5 10 15 20 30 50 75 100 200 300 500 750 1000 1500 2000 3000 5000 Illuminance [lx] General Calculation algorithm used : Direct component Maintenance factor : 0.8 Height (phot.centre): 2.97 m Maximum I : 93 cd <= 900 cd Anti panic area: Surface No.Emin [lx]Emax [lx]Ud Anti panic area 1.1 Calculation field: 2.1m x 3.7m (5 x 8 pts), Height = 0.00m 1 0.88 lx 1.50 lx 1: 1.70 >= 0.5 lx >= 1 : 40 Type No.\Make BELL Lighting Limited 9 1E x Order No. : !EM2 09126 -- Emergency Lighting -- Luminaire name : Spectrum 2W Open Area 4 in 1 Emergency Downlight Equipment : 1 x LED 6500K EM 1.2 W / 175 lm (0%) Emergency : 175 lm Maintenance factor: 0.80 RECEIVED: 20/07/2026 1.05 Tea Station Description, 1.05 Tea Station Floor plan Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 51/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 0.0 0.5 1.0 1.5 2.0 2.5 3.0 x [m] 0.0 0.5 1.0 1.5 2.0 2.5 3.0 y [m] 2.502.000.80 2.40 0.80 Wall x y Length Area[m²] Reflectance 1 3.39 m 9.20 m 3.28 m 9.84 50.0 % 2 3.39 m 12.50 m 3.30 m 9.90 50.0 % 3 0.11 m 12.50 m 3.28 m 9.84 50.0 % 4 0.11 m 9.20 m 3.30 m 9.90 50.0 % Floor: 10.8 20.0 % Ceiling: 10.8 70.0 % Room height [m]: 3.00 m Height of ref. plane [m]: 0.75 m Volume 32.5 m³RECEIVED: 20/07/2026 1.05 Tea Station Summary, 1.05 Tea Station Result overview, Evaluation area 1 Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 52/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 0.0 0.5 1.0 1.5 2.0 2.5 3.0 x [m] 2.502.000.80 2.40 0.80 Boundary line at 300 lx 200 300 Illuminance [lx] General Calculation algorithm used Average indirect fraction Height of luminaire plane 3.00 m Maintenance factor 0.80 Total lamp luminous flux 5236.00 lm Luminaire luminous flux 5235.79 lm Total power 40.0 W Total power per area (10.82 m²)3.70 W/m² (1.49 W/m²/100lx) Evaluation area 1 Reference plane 1.1 Usage profile Canteens and break areas 10.1 (EN 12464-1, 11.2021) (Ra >80.00) Horizontal cylindrical E̅m 248 lx (>= 200 lx)102 lx (>= 75 lx) Emin 211 lx 85 lx Emin/E̅m (Uo)0.85 (>= 0.40)0.83 (>= 0.10) Emin/Emax (Ud)0.78 Ez/Eh 0.32 Position 0.75 m 1.40 m Major surfaces E̅m Uo Type No.\Make RECEIVED: 20/07/2026 1.05 Tea Station Summary, 1.05 Tea Station Result overview, Evaluation area 1 Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 53/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design BELL Lighting Limited 13 4 x Order No.: !D 10950 Luminaire name : Arial Pro 6W-10W CCT Downlight IP44 Equipment : 1 x LED 4000K 10 W / 1309 lm RECEIVED: 20/07/2026 1.05 Tea Station Summary, 1.05 Tea Station Result overview (emergency lighting) Object Installation Project number Date : Phase 4 Cloghvalley : Proposed Lighting Design : LD8012 : 01.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 54/54LD8012 Phase 4 Cloghvalley - Proposed Lighting Design 0.0 0.5 1.0 1.5 2.0 2.5 3.0 x [m] 2.502.000.80 2.40 0.80 0 0.5 1 5 10 15 20 30 50 75 100 200 300 500 750 1000 1500 2000 3000 5000 Illuminance [lx] General Calculation algorithm used : Direct component Maintenance factor : 0.8 Height (phot.centre): 2.97 m Maximum I : 93 cd <= 900 cd Anti panic area: Surface No.Emin [lx]Emax [lx]Ud Anti panic area 1.1 Calculation field: 2.29m x 2.32m (7 x 7 pts), Height = 0.00m 1 0.90 lx 1.52 lx 1: 1.68 >= 0.5 lx >= 1 : 40 Type No.\Make BELL Lighting Limited 9 1E x Order No. : !EM2 09126 -- Emergency Lighting -- Luminaire name : Spectrum 2W Open Area 4 in 1 Emergency Downlight Equipment : 1 x LED 6500K EM 1.2 W / 175 lm (0%) Emergency : 175 lm Maintenance factor: 0.80 RECEIVED: 20/07/2026