Loading...
HomeMy WebLinkAbout2660160 - F.I. Received Doc. - Exterior proposed lighting designBELL Lighting Design lightingdesign@belllighting.co.uk Page 1/20LD8012 Phase 4 Cloghvalley Exterior - Proposed Lighting Design Phase 4 Cloghvalley Exterior Installation : Proposed Lighting Design Project number : LD8012 Customer : National Electrical Wholesalers, Drogheda Processed by : Glinda Shaji Date : 02.07.2026 Project description: Design based on information provided and aimed to achieve relevant guidelines, shown on results overview page for your verification and approval prior to any orders are placed. We have utilised our Virtus 50W-100W CCT Asymmetric Floodlight (type EX1) mounted on the building @ 5.5m AFGL and Lumo2 CCT Asymmetric Wallpack IP66 (type EX2) mounted on the walls @ 3.0m AFFL. We have also shown day 1 resulting glare, upward light and horizontal spillage figures for your consideration and approval. The following values are based on precise calculations performed on calibrated lamps and luminaires, and their configurations, whereby gradual, unavoidable deviations can occur in practice. All guarantee claims are excluded for the specified data. This exclusion of liability applies irrespective of the legal grounds for both damages and consequential damages suffered by users and third parties. Full installation vertical tilt and aiming angles or aiming coordinates guidance must be confirmed with lighting design department prior placing an order. Be advised that if luminaire re-aiming or site commissioning is required for the aforementioned project, please contact BELL Lighting for a site-specific quote, these services are not included in the provided quotation. Engineer assessment of column capabilities required to understand if it is possible to mount proposed floodlights on the installed columns. Suitable columns or any additional brackets are excluded and to be provided by others (unless otherwise specified). If our proposals are based on Google Maps, competitor's proposals, photographs or unscaled drawings, results are indicative only and full site survey will be required prior to placing an order. Please verify usage and target lux levels (specified on results overview page), dimensions, heights and if all areas requiring lighting design are included. Design concluded assuming there is no change in ground level, obstruction to lighting or light fittings other than specified on plans/information provided or those which can be identified from Google Maps images used. Any assumptions made at design stage should be verified prior to placing any orders, any additional luminaires will be subject to an additional cost. Please and do not hesitate to contact us if any alterations or additional details required.RECEIVED: 20/07/2026 Phase 4 Cloghvalley Exterior Description, Phase 4 Cloghvalley Exterior Floor plan Object Installation Project number Date : Phase 4 Cloghvalley Exterior : Proposed Lighting Design : LD8012 : 02.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 2/20LD8012 Phase 4 Cloghvalley Exterior - Proposed Lighting Design -1 4 9 14 19 24 29 34 39 44 49 x [m] -1 4 9 14 19 24 29 34 39 44 y [m] 37.5333.1524.6816.0711.70 29.35 27.36 24.36 18.69 15.19 6.68 3.10RECEIVED: 20/07/2026 Description, Phase 4 Cloghvalley Exterior 3D view, Visualisation 1 Object Installation Project number Date : Phase 4 Cloghvalley Exterior : Proposed Lighting Design : LD8012 : 02.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 3/20LD8012 Phase 4 Cloghvalley Exterior - Proposed Lighting Design RECEIVED: 20/07/2026 Description, Phase 4 Cloghvalley Exterior 3D view, Visualisation 2 Object Installation Project number Date : Phase 4 Cloghvalley Exterior : Proposed Lighting Design : LD8012 : 02.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 4/20LD8012 Phase 4 Cloghvalley Exterior - Proposed Lighting Design RECEIVED: 20/07/2026 Description, Phase 4 Cloghvalley Exterior 3D view, Visualisation 3 Object Installation Project number Date : Phase 4 Cloghvalley Exterior : Proposed Lighting Design : LD8012 : 02.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 5/20LD8012 Phase 4 Cloghvalley Exterior - Proposed Lighting Design RECEIVED: 20/07/2026 Phase 4 Cloghvalley Exterior Summary, Phase 4 Cloghvalley Exterior Result overview, Walkway Around Building Object Installation Project number Date : Phase 4 Cloghvalley Exterior : Proposed Lighting Design : LD8012 : 02.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 6/20LD8012 Phase 4 Cloghvalley Exterior - Proposed Lighting Design -1 4 9 14 19 24 29 34 39 44 49 x [m] 37.5324.6816.07 29.35 24.36 18.69 15.19 6.68 3.10 5 10 15 20 30 50 75 Illuminance [lx] General Calculation algorithm used Average indirect fraction Maintenance factor 0.80 Total lamp luminous flux 74924.00 lm Luminaire luminous flux 74923.69 lm Total power 420.0 W Workplace Task area Results Overview (1) Usage profile Walkways exclusively for pedestrians 7.1 (EN 12464-2, 2024.11) (Ra >70.00) E̅m 41 lx (>= 5 lx) Emin 9.35 lx Emax 78 lx Emin/E̅m (Uo)0.23 (>= 0.20) Emin/Emax (Ud)0.12 Position 0.00 m Type No.\Make BELL Lighting Limited 1 7 x Order No. : !EX1 70470 Luminaire name : Virtus 50W-100W CCT Asymmetric Floodlight Equipment : 1 x LED 740 50 W / 9332 lm RECEIVED: 20/07/2026 Phase 4 Cloghvalley Exterior Summary, Phase 4 Cloghvalley Exterior Result overview, Walkway Around Building Object Installation Project number Date : Phase 4 Cloghvalley Exterior : Proposed Lighting Design : LD8012 : 02.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 7/20LD8012 Phase 4 Cloghvalley Exterior - Proposed Lighting Design 2 5 x Order No.: !EX2 70120 Luminaire name : Lumo2 CCT Asymmetric Wallpack IP66 Equipment : 1 x LED 4000K 14 W / 1920 lm RECEIVED: 20/07/2026 Summary, Phase 4 Cloghvalley Exterior Result overview, Parking 1 Object Installation Project number Date : Phase 4 Cloghvalley Exterior : Proposed Lighting Design : LD8012 : 02.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 8/20LD8012 Phase 4 Cloghvalley Exterior - Proposed Lighting Design -1 4 9 14 19 24 29 34 39 44 49 x [m] 37.5324.6816.07 29.35 24.36 18.69 15.19 6.68 3.10 5 10 15 20 30 Illuminance [lx] General Calculation algorithm used Average indirect fraction Maintenance factor 0.80 Total lamp luminous flux 74924.00 lm Luminaire luminous flux 74923.69 lm Total power 420.0 W Workplace Task area Results Overview (1) Usage profile Medium traffic, e.g. parking areas of department stores, office buildings, plants, sports and multipurpose buildingcomplexes 8.2 (EN 12464-2, 2024.11) (Ra >70.00) E̅m 21 lx (>= 10 lx) Emin 7.50 lx Emax 41 lx Emin/E̅m (Uo)0.36 (>= 0.25) Emin/Emax (Ud)0.18 Position 0.00 m Type No.\Make RECEIVED: 20/07/2026 Summary, Phase 4 Cloghvalley Exterior Result overview, Parking 1 Object Installation Project number Date : Phase 4 Cloghvalley Exterior : Proposed Lighting Design : LD8012 : 02.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 9/20LD8012 Phase 4 Cloghvalley Exterior - Proposed Lighting Design BELL Lighting Limited 1 7 x Order No.: !EX1 70470 Luminaire name : Virtus 50W-100W CCT Asymmetric Floodlight Equipment : 1 x LED 740 50 W / 9332 lm 2 5 x Order No.: !EX2 70120 Luminaire name : Lumo2 CCT Asymmetric Wallpack IP66 Equipment : 1 x LED 4000K 14 W / 1920 lm RECEIVED: 20/07/2026 Summary, Phase 4 Cloghvalley Exterior Result overview, Parking 2 Object Installation Project number Date : Phase 4 Cloghvalley Exterior : Proposed Lighting Design : LD8012 : 02.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 10/20LD8012 Phase 4 Cloghvalley Exterior - Proposed Lighting Design -1 4 9 14 19 24 29 34 39 44 49 x [m] 37.5324.6816.07 29.35 24.36 18.69 15.19 6.68 3.10 10 15 20 30 Illuminance [lx] General Calculation algorithm used Average indirect fraction Maintenance factor 0.80 Total lamp luminous flux 74924.00 lm Luminaire luminous flux 74923.69 lm Total power 420.0 W Workplace Task area Results Overview (1) Usage profile Medium traffic, e.g. parking areas of department stores, office buildings, plants, sports and multipurpose buildingcomplexes 8.2 (EN 12464-2, 2024.11) (Ra >70.00) E̅m 23 lx (>= 10 lx) Emin 10.5 lx Emax 32 lx Emin/E̅m (Uo)0.46 (>= 0.25) Emin/Emax (Ud)0.32 Position 0.00 m Type No.\Make RECEIVED: 20/07/2026 Summary, Phase 4 Cloghvalley Exterior Result overview, Parking 2 Object Installation Project number Date : Phase 4 Cloghvalley Exterior : Proposed Lighting Design : LD8012 : 02.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 11/20LD8012 Phase 4 Cloghvalley Exterior - Proposed Lighting Design BELL Lighting Limited 1 7 x Order No.: !EX1 70470 Luminaire name : Virtus 50W-100W CCT Asymmetric Floodlight Equipment : 1 x LED 740 50 W / 9332 lm 2 5 x Order No.: !EX2 70120 Luminaire name : Lumo2 CCT Asymmetric Wallpack IP66 Equipment : 1 x LED 4000K 14 W / 1920 lm RECEIVED: 20/07/2026 Summary, Phase 4 Cloghvalley Exterior Result overview, Parking 3 Object Installation Project number Date : Phase 4 Cloghvalley Exterior : Proposed Lighting Design : LD8012 : 02.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 12/20LD8012 Phase 4 Cloghvalley Exterior - Proposed Lighting Design -1 4 9 14 19 24 29 34 39 44 49 x [m] 37.5324.6816.07 29.35 24.36 18.69 15.19 6.68 3.10 5 10 15 20 30 Illuminance [lx] General Calculation algorithm used Average indirect fraction Maintenance factor 0.80 Total lamp luminous flux 74924.00 lm Luminaire luminous flux 74923.69 lm Total power 420.0 W Workplace Task area Results Overview (1) Usage profile Medium traffic, e.g. parking areas of department stores, office buildings, plants, sports and multipurpose buildingcomplexes 8.2 (EN 12464-2, 2024.11) (Ra >70.00) E̅m 20 lx (>= 10 lx) Emin 5.76 lx Emax 40 lx Emin/E̅m (Uo)0.28 (>= 0.25) Emin/Emax (Ud)0.14 Position 0.00 m Type No.\Make RECEIVED: 20/07/2026 Summary, Phase 4 Cloghvalley Exterior Result overview, Parking 3 Object Installation Project number Date : Phase 4 Cloghvalley Exterior : Proposed Lighting Design : LD8012 : 02.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 13/20LD8012 Phase 4 Cloghvalley Exterior - Proposed Lighting Design BELL Lighting Limited 1 7 x Order No.: !EX1 70470 Luminaire name : Virtus 50W-100W CCT Asymmetric Floodlight Equipment : 1 x LED 740 50 W / 9332 lm 2 5 x Order No.: !EX2 70120 Luminaire name : Lumo2 CCT Asymmetric Wallpack IP66 Equipment : 1 x LED 4000K 14 W / 1920 lm RECEIVED: 20/07/2026 Summary, Phase 4 Cloghvalley Exterior Result overview, Parking 4 Object Installation Project number Date : Phase 4 Cloghvalley Exterior : Proposed Lighting Design : LD8012 : 02.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 14/20LD8012 Phase 4 Cloghvalley Exterior - Proposed Lighting Design -1 4 9 14 19 24 29 34 39 44 49 x [m] 37.5324.6816.07 29.35 24.36 18.69 15.19 6.68 3.10 15 20 30 50 Illuminance [lx] General Calculation algorithm used Average indirect fraction Maintenance factor 0.80 Total lamp luminous flux 74924.00 lm Luminaire luminous flux 74923.69 lm Total power 420.0 W Workplace Task area Results Overview (1) Usage profile Car charging station points in lit areas 8.3 (EN 12464-2, 2024.11) (Ra >70.00) E̅m 42 lx (>= 20 lx) Emin 16.6 lx Emax 65 lx Emin/E̅m (Uo)0.39 (>= 0.25) Emin/Emax (Ud)0.26 Position 0.00 m Type No.\Make BELL Lighting Limited 1 7 x Order No. : !EX1 70470 Luminaire name : Virtus 50W-100W CCT Asymmetric Floodlight Equipment : 1 x LED 740 50 W / 9332 lm RECEIVED: 20/07/2026 Summary, Phase 4 Cloghvalley Exterior Result overview, Parking 4 Object Installation Project number Date : Phase 4 Cloghvalley Exterior : Proposed Lighting Design : LD8012 : 02.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 15/20LD8012 Phase 4 Cloghvalley Exterior - Proposed Lighting Design 2 5 x Order No.: !EX2 70120 Luminaire name : Lumo2 CCT Asymmetric Wallpack IP66 Equipment : 1 x LED 4000K 14 W / 1920 lm RECEIVED: 20/07/2026 Summary, Phase 4 Cloghvalley Exterior Result overview, Evaluation area 1 Object Installation Project number Date : Phase 4 Cloghvalley Exterior : Proposed Lighting Design : LD8012 : 02.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 16/20LD8012 Phase 4 Cloghvalley Exterior - Proposed Lighting Design -1 4 9 14 19 24 29 34 39 44 49 x [m] 37.5324.6816.07 29.35 24.36 18.69 15.19 6.68 3.10 1 5 10 15 20 30 50 Illuminance [lx] General Calculation algorithm used Average indirect fraction Maintenance factor 0.80 Total lamp luminous flux 74924.00 lm Luminaire luminous flux 74923.69 lm Total power 420.0 W Total power per area (2044.32 m²)0.21 W/m² (0.70 W/m²/100lx) Evaluation area 1 Reference plane 1.1 Horizontal E̅m 29 lx Emin 1.28 lx Emin/E̅m (Uo)0.04 Emin/Emax (Ud)0.02 Position 0.00 m RG Table 0.08 cd/m², 37 lx, ρ = 0 % (-2°) RG,max 49.9 (h=3.20m)RECEIVED: 20/07/2026 Summary, Phase 4 Cloghvalley Exterior Result overview, Evaluation area 1 Object Installation Project number Date : Phase 4 Cloghvalley Exterior : Proposed Lighting Design : LD8012 : 02.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 17/20LD8012 Phase 4 Cloghvalley Exterior - Proposed Lighting Design Type No.\Make BELL Lighting Limited 1 7 x Order No.: !EX1 70470 Luminaire name : Virtus 50W-100W CCT Asymmetric Floodlight Equipment : 1 x LED 740 50 W / 9332 lm 2 5 x Order No.: !EX2 70120 Luminaire name : Lumo2 CCT Asymmetric Wallpack IP66 Equipment : 1 x LED 4000K 14 W / 1920 lm RECEIVED: 20/07/2026 Summary, Phase 4 Cloghvalley Exterior Result overview, Results Overview (1) Object Installation Project number Date : Phase 4 Cloghvalley Exterior : Proposed Lighting Design : LD8012 : 02.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 18/20LD8012 Phase 4 Cloghvalley Exterior - Proposed Lighting Design 5 4 3 2 1 Horizontal illuminance No.Measuring surface Grid E̅m Emin Emax Uo Ud 1.1 Walkway Around Building 62 x 65 41.1 lx 9.3 lx 78.4 lx 0.23 0.12 1.2 Parking 1 9 x 9 21.1 lx 7.5 lx 41.3 lx 0.36 0.18 1.3 Parking 2 9 x 28 22.7 lx 10.5 lx 32.5 lx 0.46 0.32 1.4 Parking 3 9 x 52 20.3 lx 5.8 lx 39.8 lx 0.28 0.14 1.5 Parking 4 9 x 29 42.5 lx 16.6 lx 64.6 lx 0.39 0.26 Summary 37.5 lx 5.8 lx 78.4 lx 0.15 0.07RECEIVED: 20/07/2026 Phase 4 Cloghvalley Exterior(Horizontal Spillage) Description, Phase 4 Cloghvalley Exterior(Horizontal Spillage) Floor plan Object Installation Project number Date : Phase 4 Cloghvalley Exterior : Proposed Lighting Design : LD8012 : 02.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 19/20LD8012 Phase 4 Cloghvalley Exterior - Proposed Lighting Design -8 2 12 22 32 42 52 x [m] -4 0 6 10 16 20 26 30 36 40 46 y [m] 37.5333.1524.6816.0711.70 29.35 27.36 24.36 18.69 15.19 6.68 3.10RECEIVED: 20/07/2026 Phase 4 Cloghvalley Exterior(Horizontal Spillage) Calculation results, Phase 4 Cloghvalley Exterior(Horizontal Spillage) Boundary line, Horizontal Spillage (E) Object Installation Project number Date : Phase 4 Cloghvalley Exterior : Proposed Lighting Design : LD8012 : 02.07.2026 BELL Lighting Design lightingdesign@belllighting.co.uk Page 20/20LD8012 Phase 4 Cloghvalley Exterior - Proposed Lighting Design -8 2 12 22 32 42 52 x [m] -4 0 6 10 16 20 26 30 36 40 46 y [m] 37.5324.6816.07 29.35 24.36 18.69 15.19 6.68 3.10 0 5 10 Illuminance [lx] Height reference plane : 0.00 m Average illuminance E̅m : 16.6 lx Minimum illuminance Emin : 0.24 lx Maximum illuminance Emax : 73 lx Uniformity Uo Emin/E̅m : 1 : 70.00 (0.01)RECEIVED: 20/07/2026