Loading...
HomeMy WebLinkAbout2660126 - F.I. Maps. No 2 (2)DIRECTION OF TRAVELENVELOPE OF VISIBILITYENVELOPE OF VISIBILITY490174900070.00075.00080.00085.00090.000STOPPING SIGHT DISTANCESTOPPING SITE DISTANCE70.00075.00080.00085.00090.000ROAD LEVEL ALONGVISIBILITY SPLAYENVELOPE OF VISIBILITYAS PER DMURSKEY:600 2000 600 2000 2000 1050HORIZONTAL SIGHT LINE1 : 250DIRECTION OF TRAVEL1875 1400E N T R A N C E D E T A I LS07DETAILScale 1:501875200040mm of 10mm nominal size close gradedwearing course bitumen macadam to comply with BS 4987.60mm of 20mm nominal size dense basecoursebitumen macadam to comply with BS 4987.100mm dense bitumen macadam roadbase.150mm of sub-base material comprising type B granularmaterial in accordance with clause 804 of the specificationfor roadworks.300-480mm of capping layer comprising crushed rock onlayer of terram.200 100200 X 200 MARSHALLSSPEEDCHECK CONCRETEROAD HUMP LAID ON 450 x150 CONCRETE HAUNCHING6°5750200 X 100 X 80 MARSHALLS V-GROOVEKEYBLOK LAID ON 50MM SHARP SANDBED ON LEAN MIX CONCRETE.200 TOP OF KERB1875200 100200 X 200 MARSHALLSSPEEDCHECK CONCRETEROAD HUMP LAID ON 450 x150 CONCRETE HAUNCHING6°200 X 100 X 80 MARSHALLS V-GROOVEKEYBLOK LAID ON 50MM SHARP SANDBED ON LEAN MIX CONCRETE.200 TOP OF KERBR A I S E D T A B L E D E T A I LS06DETAILScale 1:256 Plantation TerraceMonaghanCo.Monaghan© copyright of mcguigan architects ltdM c G U I G A NARCHITECTS+353 47 77823info@mcguiganarchitects.comwww.mcguiganarchitects.comProjectAddressClientScaleFormatStatusDrawn ByStart DateDrawing TitleDrawing NumberAll dimensions to be taken on site - no dimensions to be scaled from thisdrawing. This drawing to be read in conjunction with all other relevantdrawings, specifications etc.Any discrepancies to be reported to the Architect for clarification. Thisdrawing may not be copied or reproduced without written consent.PLEASE NOTE THAT THIS IS A PLANNING DRAWING ONLY AND ISTHEREFORE LIMITED IN ITS CAPACITY TO CONVEY THE TOTALINFORMATION, DETAILS & SPECIFICATIONS NECESSARY TOCOMPLETE THE WORKS. ANY WORK CARRIED OUT THAT IS NOTSPECIFIED OR DETAILED HERE WILL BE THE RESPONSIBILITY OF THEPERSONS CARRYING THEM OUT. IF ANY SITUATION ARISES WHICHWOULD CAUSE A CONTRAVENTION OF THE BUILDINGREGULATIONS, THEN THE ARCHITECT SHOULD BE CONSULTED,OTHERWISE THE ARCHITECT CANNOT BE HELD RESPONSIBLE.ALL WORK AND MATERIALS ARE TO BE IN ACCORDANCE WITHCURRENT BUILDING REGULATIONS WHETHER DETAILED ON THISDRAWING OR NOT.NOTESMRIAI RIBA Chartered ArchitectsPassivHaus DesignersEnergy ConsultantsFOUNDED 1839T H E R O YAL THEOFOFIN NST T TI UEARCHITTECSDALERIALL DIMENSIONS TO BE TAKEN ON SITE -NO DIMENSIONS TO BE SCALED FROM THIS DRAWING.THIS DRAWING TO BE READ IN CONJUNCTION WITH ALL OTHERRELEVANT DRAWINGS, SPECIFICATIONS ETC.ANY DISCREPANCIES TO BE REPORTED TO THE ARCHITECT FORCLARIFICATION. THIS DRAWING MAY NOT BE COPIED ORREPRODUCED WITHOUT WRITTEN CONSENT.NO WORKS SHOULD BE CARRIED OUT WITHOUT PRIOR CONSENTFROM THE LOCAL PLANNING AUTHORITY.PROPOSED DEVELOPMENTKILLYCONIGANMONAGHANCO.MONAGHANHADABO DEVELOPMENTSLTD1:25 / 50 / 250A1PLANNINGMMMARCH 2026SIGHT LINES & BOUNDARYTREATMENT DETAILSMGA-018-0181-PL110P L A N N I N G O N L Y---RECEIVED: 21/07/2026