Loading...
HomeMy WebLinkAbout2660334 - Site layout planTHIS DRAWING IS TO BE READ IN CONJUNCTION WITH ALL OTHER S&AA DRAWINGS Hall Street, Kingscourt, Co. Cavan e: info@saarchitects.ie A82 D1H7 t: (042) 9693700 w: www.saarchitects.ie CLIENT: STAGE: PROJECT: DRAWING TITLE: DRAWING NO:REV: - DATE: SCALE:DWG BY:JOB NO: REVISION: Figured dimensions ONLY to be taken from this drawing. All dimensions to be checked on site. Any discrepancies to be brought to the aƩenƟon of this office prior to commencement. This drawing is Copyright. This document is the property of Smith & Associates Architects. This document is not to be used, reproduced or circulated without the prior wriƩen permission, in each instance, from Smith & Associates Architects © PLANNING DRAWINGS PROPOSED EXTENSION & ALTERATIONS TO EXISTING DWELLING AT BALLYCARTLAN, MAGHERACLOONE, CO. MONAGHAN. 1:500 JUNE '26 CD 3431 PROPOSED SITE LAYOUT PLAN. DANE & BRIONI MCMAHON. PL(00)002 @A3 99.750 99.850 99.85099.850 99.850 101.000 99.800 101.050101.100 101.000 100.250 N 3.6 7.332.017.3 17.7 SMALL PORTION OF EXISTING STONE WALL TO BE CAREFULLY DEMOLISHED. PROPOSED STORMWATER TAKEN TO SOAKAWAY AS INDICATED. MAIN ENTRANCE EXTERNAL TERRACE EXISTING RECESSED ENTRANCE SERVICE AREA SITE NOTICE LOCATION ON EXISTING ENTRANCE PIER. EXISTING GROUND TO BE REGRADED/ SLOPED BACK TO EXISTING GARDEN LEVEL. EXISTING SITE BOUNDARY TO REMAIN. OUTLINE OF EXISTING PITCHED ROOF EXTENSION TO BE CAREFULLY DEMOLISHED. EXISTING SITE BOUNDARY TO REMAIN. EXISTING TREES/HEDGING & LOW LEVEL STONE WALL TO REMAIN. EXISTING DWELLING FFL: 100.00 PROPOSED EXTENSION.FFL: +100.00LANDSCAPED ENTRANCE COURTYARD REAR ENTRANCE SITE AREA 0.245 ha / 0.60 acre AREA OUTLINED IN RED INDICATES AREA FOR PLANNING PERMISSION OWNED BY THE APLICANT.EXISTING BOUNDARY HEDGE TO REMAINEXISTING REAR GARDEN TERRACE EXISTING PERCOLATION AREA EXISTING SEPTIC TANK LANDSCAPED GARDEN EXISTING GATE FLAT ROOF EXTENSION FAMILY OWNED SHEDS. EXISTING POST & WIRE FENCE TO REMAIN EXISTING POLYTUNNELEXISTING WATER SUPPLY: MAGHERACLOONE GROUP WATER SCHEME. TOTAL BUILDING AREA Existing Area Level / Floor: EXISTING FIRST FLOOR: EXISTING GROUND FLOOR AREA: PROPOSED FIRST FLOOR: PROPOSED GROUND FLOOR AREA: Area: 35.64 76.34 58.00 76.12 246.10 m² ROOM SCHEDULE Ground Floor Room Number G.01 G.02 G.03 G.04 G.05 G.06 G.07 G.08 G.09 Room Name TV ROOM RECEPTION PLAYROOM STORAGE HALL SH ROOM. UTILITY KITCHEN DINING Area 16.44 17.88 28.98 9.95 19.93 8.83 10.99 26.75 19.60 N SUNRISE8:44 AMDAYLIGHT SCHEME SUMMER SOLSTICE SUN: LANDSCAPING LEGEND: EXISTING TREES TO BERETAINED & SUPPLEMENTED. EXISTING HEDGINGTO REMAIN. PROPOSED NEWHEDGING. LANDSCAPING PLAN: SITE AREA 0245 ha / 0.60 acre AREA OUTLINED IN RED INDICATES AREA FOR PLANNING PERMISSION OWNED BY THE APPLICANT. WASTEWATER DRAINAGE SYSTEM STORM WATER DRAINAGE SYSTEM PROPOSED MAPLE TREE PROPOSED BEECH TREE PROPOSED OAK TREE PROPOSED ASH TREE DECORATIVE PLANTS NAME OF TREESYMBOL HEIGHT OF PLANT/ GROWTH FIVE YEARS/ GROWTH TEN YEARS 4/5/6m 3/4/7m 4/6/6,5m 2.5/3.8/5m SUNSET 4:07 PM SUNRISE 04:55 AMSUNSET10:03 PMNNDAYLIGHT SCHEME WINTER SOLSTICE SUN: PROPOSED EXTENSION PROPOSED DEMOLITIONS Site Layout Plan 1:500 RECEIVED: 07/08/2026