Loading...
HomeMy WebLinkAbout2660123 - F.I. Received Doc. - Technical Data SheetAIDAN SHERLOCK & ASSOCIATES LTD | Planning & Architectural Consultants ASA–UNS–TDS–001 Rev A Technical Data Sheet — Bulk LPG Storage Vessel Page 1 of 10 TECHNICAL DATA SHEET Above-Ground Bulk LPG Storage Vessel and Enclosure Project Urbleshanny National School, Scotstown, Co. Monaghan Subject Existing above-ground bulk LPG storage vessel, base and security enclosure Planning reference 26/60123 — Monaghan County Council Document reference Revision / status Rev A — For information Date 5 August 2026 Prepared by Aidan Sherlock & Associates Ltd Basis of record Site photograph dated 16 July 2026 and published supplier / standard data 1. Purpose and Scope This data sheet records the technical characteristics, dimensions and siting requirements of the above -ground bulk LPG storage vessel serving Urbleshanny National School, together with its concrete base and weldmesh security enclosure. It has been prepared to support the planning and design record for the site and to allow the installation to be shown accurately, and with correct separation distances annotated, on site layout drawings. The vessel is a Flogas-supplied horizontal above-ground propane vessel located within a fenced compound adjacent to the all-weather pitch, with a covered seating shelter immediately adjoining to the east. 2. Identification of the Installed Vessel The nominal capacity of a bulk LPG vessel cannot be determined with certainty from a photograph. However, the proportions of the installed vessel — an overall length of approximately twice the shell diameter, a single centrally - mounted weatherproof valve cover, and low welded saddle feet bearing directly onto a concrete pad — are consistent with a nominal 1,410 litre (0.6 tonne propane) vessel, which is the standard size supplied for lower -consumption commercial and light institutional heating loads. The data in Section 3 is therefore presented for a 1,410 litre vessel as the assumed installed unit, with the adjacent standard sizes tabulated in Section 4 for comparison. The serial number, water capacity and design pressure are stamped on the vessel data plate beneath the valve cover, and should be read off on site or confirmed with Flogas Ireland Ltd before the figures below are relied upon for any statutory submission. 3. Vessel Technical Data Assumed installed unit — nominal 1,410 litre above-ground horizontal propane vessel. Description Horizontal above-ground bulk LPG storage vessel on welded steel saddle feet Supplier Flogas Ireland Ltd (vessel typically remains supplier property under tank rental agreement) Product stored Commercial propane Nominal water capacity 1,410 litres Maximum fill 85% of water capacity — approximately 1,200 litres of liquid Nominal propane content Approximately 600 kg (0.6 tonne) Overall length 2,022 mm RECEIVED: 05/08/2026 AIDAN SHERLOCK & ASSOCIATES LTD | Planning & Architectural Consultants ASA–UNS–TDS–001 Rev A Technical Data Sheet — Bulk LPG Storage Vessel Page 2 of 10 Shell diameter 1,000 mm Overall height above slab 1,300 mm (to top of valve cover) Underside clearance Approximately 100 mm above slab Approximate tare weight 500 kg (vessel empty) Approximate filled weight 1,100 kg (vessel plus maximum fill) Design pressure Typically in the order of 14.5 bar — confirm against vessel data plate Vessel construction Welded carbon steel pressure vessel, designed, manufactured, tested and CE - marked to the Pressure Equipment Directive 2014/68/EU External finish Shot-blasted, primed and finished in a light reflective colour (pale green or white) to limit solar gain Fittings Multi-valve assembly beneath a weatherproof cover, comprising fill valve, service / vapour offtake valve, pressure relief valve, contents gauge and ullage or bleed valve Base requirement Reinforced concrete slab, 2,000 × 1,000 × 100 mm minimum, level and free- draining Separation distance 3.0 m to buildings, boundaries, property lines, fixed sources of ignition and unsealed drains Installation standard I.S. 3216 — Code of Practice for the Bulk Storage of Liquefied Petroleum Gas RECEIVED: 05/08/2026 AIDAN SHERLOCK & ASSOCIATES LTD | Planning & Architectural Consultants ASA–UNS–TDS–001 Rev A Technical Data Sheet — Bulk LPG Storage Vessel Page 3 of 10 4. Standard Above-Ground Vessel Range For comparison, and to allow the installed vessel to be confirmed against the supplier range. Dimensions in millimetres unless noted. Nominal capacity Propane content Length Diameter Height Base slab (min.) Separation distance 1,410 L 600 kg (0.6 t) 2,022 1,000 1,300 2,000 × 1,000 × 100 3.0 m (1.5 m with firewall) 2,200 L 1,000 kg (1.0 t) 3,042 1,000 1,300 3,000 × 1,000 × 100 3.0 m (1.5 m with firewall) 4,600 L 2,000 kg (2.0 t) 4,380 1,200 1,650 4,400 × 1,250 × 150 7.5 m (4.0 m with firewall) The shaded row is the assumed installed unit. Note that separation distance increases sharply above 2,500 litres. 5. Siting and Separation Requirements The following apply to above-ground vessels up to 2,500 litres and are measured in plan from the vessel. They are illustrated in Figure 4. – 3.0 m minimum to any building, site boundary, property line or fixed source of ignition. – 3.0 m minimum to any unsealed drain, gully or opening below ground level, LPG vapour being heavier than air. – 3.0 m minimum between the LPG vessel and any oil storage tank. – The 3.0 m distance may be reduced to 1.5 m on one side only where an imperforate firewall of brick, concrete or solid masonry is provided. The firewall must be higher than the vessel, must contain no openings, and the full separation must be maintained on all remaining sides. Certain existing boundary walls may qualify where their construction is suitable. – 1.5 m minimum in plan to low-voltage overhead cables, and 10.0 m to high-voltage overhead cables. – Where a screen or enclosure is provided, it must stand a minimum of 1.0 m clear of the vessel and enclose one side only for vessels up to 2,500 litres. – Vegetation, deciduous trees, rubbish, sheds, fencing and combustible storage must be kept outside the 3.0 m zone. Evergreen planting may be permitted at 1.0 m on one side only. – The delivery tanker must be able to stand within 30 m of the vessel with a clear driver line of sight to it throughout filling. Gate access of 2.8 m minimum width and an access road of 3.0 m minimum width are required. 6. Base, Enclosure and Signage 6.1 Base – Level reinforced concrete slab, 100 mm minimum thickness, laid on a compacted granular sub -base and finished to falls away from the vessel. – Slab to extend beyond the vessel footprint on all sides and to be maintained free-draining and clear of ponding. – Saddle feet to be bedded or bolted to the slab in accordance with the supplier’s installation instructions. 6.2 Security enclosure – Welded mesh fence panels on galvanised or polyester powder -coated steel posts, 1,800 mm minimum height, with a lockable access gate. – Minimum 1.0 m clear between the enclosure and the vessel on all sides, as constructed on site. RECEIVED: 05/08/2026 AIDAN SHERLOCK & ASSOCIATES LTD | Planning & Architectural Consultants ASA–UNS–TDS–001 Rev A Technical Data Sheet — Bulk LPG Storage Vessel Page 4 of 10 – Enclosure to be free-draining, kept clear of vegetation, and used for no purpose other than the gas installation. No combustible storage inside. – Keys held by the school and by the gas supplier, with access controlled and recorded. 6.3 Signage – Supplier-standard warning notice fixed to the enclosure and clearly visible on approach, carrying at minimum: LPG BULK STORAGE COMPOUND, EXTREMELY FLAMMABLE, NO SMOKING, NO NAKED FLAMES and NO UNAUTHORISED ACCESS. – Emergency contact details and the supplier’s 24-hour emergency telephone number to be displayed at the compound. – Signage to be maintained legible and replaced when faded or damaged. RECEIVED: 05/08/2026 AIDAN SHERLOCK & ASSOCIATES LTD | Planning & Architectural Consultants ASA–UNS–TDS–001 Rev A Technical Data Sheet — Bulk LPG Storage Vessel Page 5 of 10 7. Principal Reference Documents – I.S. 3216 — Code of Practice for the Bulk Storage of Liquefied Petroleum Gas. – I.S. 813 — Domestic Gas Installations, and I.S. 820 — Non-Domestic Gas Installations, in respect of downstream pipework and appliances. – Dangerous Substances Act 1972 (as amended) and regulations made thereunder in respect of the storage of LPG. – Safety, Health and Welfare at Work Act 2005 and the Safety, Health and Welfare at Work (General Application) Regulations 2007, including the provisions relating to explosive atmospheres. – Pressure Equipment Directive 2014/68/EU, as transposed into Irish law, in respect of vessel design, manufacture, testing and marking. – Building Regulations 1997–2022, Technical Guidance Document B — Fire Safety, where the installation interfaces with the building. – Flogas Ireland Ltd installation guidelines, siting guidance and customer information manual. Reference should be made to the current published editions of each of the above. 8. Verification Required The following should be confirmed before this data sheet is relied upon for a statutory submission or for design purposes: – Vessel nominal capacity, serial number, year of manufacture and design pressure, read from the data plate beneath the valve cover or obtained from Flogas Ireland Ltd. – Date of last vessel inspection and the current inspection or revalidation interval. – Measured separation distances from the vessel to the school building, the site boundary, the adjoining seating shelter, the all-weather pitch enclosure and any drainage feature, taken on site. – Confirmation that the adjoining timber-framed seating shelter and any adjacent planting satisfy the separation and combustible-material requirements set out in Section 5. – Tanker standing position, hose run length and driver line of sight, verified against the delivery route. – Whether the installation was the subject of a previous grant of permission, or is exempted development, so that it is correctly described on the site layout drawings. 9. Limitations This data sheet has been prepared from a site photograph and from published supplier and standard data. It is not a survey, a gas safety inspection or a certificate of compliance. No physical inspection, measurement or testing of the vessel or its installation has been carried out. Dimensions and technical data given for the vessel are typical published figures for the standard size assumed and may vary between manufacturers and production dates. Any works to, alteration of, or connection to the LPG installation must be carried out only by the gas supplier or by a Registered Gas Installer. Drawings on the following pages are diagrammatic and dimensioned in millimetres unless otherwise noted. They are not to scale and are not for construction. RECEIVED: 05/08/2026 AIDAN SHERLOCK & ASSOCIATES LTD | Planning & Architectural Consultants ASA–UNS–TDS–001 Rev A Technical Data Sheet — Bulk LPG Storage Vessel Page 6 of 10 Figure 1 — Side Elevation Above-ground bulk LPG vessel, nominal 1,410 litre (0.6 t propane), on reinforced concrete base slab. RECEIVED: 05/08/2026 AIDAN SHERLOCK & ASSOCIATES LTD | Planning & Architectural Consultants ASA–UNS–TDS–001 Rev A Technical Data Sheet — Bulk LPG Storage Vessel Page 7 of 10 Figure 2 — End Elevation Shell diameter, overall height and base slab width. Pressure relief valve discharges vertically upwards. RECEIVED: 05/08/2026 AIDAN SHERLOCK & ASSOCIATES LTD | Planning & Architectural Consultants ASA–UNS–TDS–001 Rev A Technical Data Sheet — Bulk LPG Storage Vessel Page 8 of 10 Figure 3 — Plan on Tank and Base Slab Vessel footprint, saddle feet positions shown dashed, and minimum extent of the concrete base slab. RECEIVED: 05/08/2026 AIDAN SHERLOCK & ASSOCIATES LTD | Planning & Architectural Consultants ASA–UNS–TDS–001 Rev A Technical Data Sheet — Bulk LPG Storage Vessel Page 9 of 10 Figure 4 — Siting and Separation Distances (Plan) Separation distances for vessels up to 2,500 litres, measured in plan from the vessel. Refer I.S. 3216. RECEIVED: 05/08/2026 AIDAN SHERLOCK & ASSOCIATES LTD | Planning & Architectural Consultants ASA–UNS–TDS–001 Rev A Technical Data Sheet — Bulk LPG Storage Vessel Page 10 of 10 Figure 5 — Security Enclosure and Signage (Elevation) Weldmesh compound arrangement, minimum clearances to the vessel, and statutory warning signage. RECEIVED: 05/08/2026