HomeMy WebLinkAbout2660122 - F.I. Received Doc. - Environmental Protection Plan Checklist
MONAGHAN LOCAL AUTHORITIES
Environment Protection Plan Checklist
This is a checklist to be completed by applicant to be backed up by an appropriate level of detail
depending. To be accompanied by a Site Drainage Plan – as set out in the Monaghan County
Development Plan 2025 – 2031.
General Site and Water Body Details
Planning Ref. No. Applicant
Townland Water Supply Source
X Co-ordinate 1 Y Co-ordinate 1
WFD River Sub Catchment2 WFD River Sub Basin2
WFD River Waterbody latest
Status 2
Status WFD River Waterbody
Risk2
WFD River Waterbody
Objectfve2
Groundwater Vulnerability Aquifer Importance
Proximity to sensitfve receptors (Private Wells, Public and Private Water Supply
Sources, Amenity Areas, SPA’s, SAC’s , NHA) (meters)
Proximity to nearest watercourse (culverted or open), wetland or lake (meters)
Existfng EPA Licence (insert licence no)
Existfng Sectfon 4 licence (insert licence no)
Proposed Development
Is the development entirely or part of one of the following? (tick)
Domestfc dwelling Agricultural (cattle/dairy) Industrial-food related
Public Works Agricultural (mushrooms) Industrial-non food
Housing Agricultural (poultry) Quarrying/extractfve
industries
Instftutfonal Agricultural (piggery) Transport related
Commercial/Retail Other agricultural –
specify below
Filling statfon/Fuel depot
Mixed Use
Development
Other
Waste Permit
Type of wastewater Produced by the proposed development (tick)
No wastewater produced
Domestfc type waste waters <5m3 per day
Domestfc type waste waters >5m3 per day 4
Waste waters produced from any trade, food,
preparatfon or business 4
Wheel wash, vehicle wash, cooling waters 4
Waste waters produced from quarrying etc 4
Other waste waters 4
Year
26/60122 Michael & Margaret Wallace
DOAGHEYS
670911 839064
Mountain Water_060Mountain(Water)_SC_10
Poor 2019 - 2024
At risk
Restore Good Ecological
X - Rock at or near surface Rk - Regionally important
aquifer - Karstified
Status
Glaslough-Tyholland GWS
11m to GWS mains at road
170m to nearest lake
N/A
N/A
Yes
Yes - typical domestic
Yes
No
No
No
No
Minimal construction phase waste water (washing concrete and cement plant)RECEIVED: 12/08/2026
Have proposals for Wastewater Management during the operational phase and full details of same
been included with the application? (tick)
Public Sewer Connectfon details (Uisce Eireann)
Existfng Wastewater Treatment System
Proposed new onsite wastewater treatment
system
No wastewater generated
Have proposals for Waste Facility aftercare and use been included with the application? (tick)
Agricultural Improvement Plan where
applicable
Closure plan and aflercare details
Proposed water sampling locatfons clearly
identffied
License or Lease agreement for the site if not
owned by the applicant.
Fuel or Outdoor Material Storage for Non-Domestic Developments - operational phase (tick)
Number of fuel storage tanks existfng or proposed on site?
Are fuel storage tanks bunded 5?
Any liquid / feedstuffs / organic / chemical / waste oil storage
on outdoor sites ?
Proposals for protection of water receptors during the Construction Phase
Has a CEMP relatfng to water protectfon and
waste management been included with the
applicatfon?
Name of person appointed to oversee the
implementatfon of the CEMP.
Hard Surface and Open Yard Areas for Non Domestic Developments (tick)
Footprint of proposed development including yard areas in m2 ______ m2
Is there potentfal for soiled yard areas from material, product waste or
manure handling, fuel dispensing, silt and soil, yard washing etc.
If yes, are silt trap(s), interceptor(s), soiled water tanks or other control
measures shown on drainage plan?
Has the use of SUDS (Sustainable Urban Drainage Systems –
http://www.susdrain.org ) been included in the design of this
development?
Development History – All Developments (tick)
Have previous pollutfon preventfon planning conditfons been complied with 6?
Does existfng development have an up to date (as constructed) site drainage plan?
Is the existfng/proposed development sewered or unsewered?
If unsewered, is the existfng wastewater treatment system fit for purpose7?
Has the storm water drainage system been examined and/or surveyed for
misconnectfons?
Is there an existfng Certfficate of Registratfon or Waste Facility Permit at the site?
Checklist of items to be included on the Site Drainage Plan (tick)
Locatfon of lakes, watercourse, wells used for water supply, or karst features on or within
25m of domestfc or 100m of non-domestfc development site
Locatfon of all clean drainage outiall points
Foul water drainage system (in Red)
N/A
Yes - proposed to use existing septic tank
N/A
N/A
N/A
N/A
N/A
N/A
None existing or proposed
N/A
No
Yes
Michael Wallace
870
Minimal construction phase washing
only.
Temporary construction phase silt
traps detailed on site drainage plan
No
N/A
No
Sewered
Yes
No. This will be
carried out pre
completion
No
N/A
Yes
YesRECEIVED: 12/08/2026
Storm water drainage system (in Blue)
Soiled yard area, soiled water drainage and management system
Storm water management system, including silt traps, oil interceptor(s) and SUDS
facilitfes
Locatfon of waste water treatment facilitfes
Locatfon of fuel storage tank(s)
Stream/Lake/Wetland/Riparian Corridors/Wells
Footnotes and Useful Information
1Projectfon in the Irish Grid
2WFD informatfon available online at www.catchments.ie
WFD mapping available online at https://gis.epa.ie/EPAMaps/Water
3Available in the groundwater mapping sectfon www.gsi.ie
4If a trade eftfuent or discharge >5m3 of domestfc type wastewater to ground is proposed a Sectfon 4
discharge licence may be required https://monaghan.ie/environment/discharge-licences/
Proposals for wastewater treatment shall be sufficient to demonstrate that the discharge will not cause
deterioratfon in water quality of the receiving water body in accordance with the requirements of the
European Communitfes Environmental Objectfves (Surface Waters) Regulatfons 2009 as amended and
the European Communitfes Environmental Objectfves (Groundwater) Regulatfons 2010 as amended.
5Guidance on Best practfce for Oil Storage (BPGCS05) and note requirements of Building Regulatfons.
6Have previous planning conditfons been complied with e.g. Has certfficatfon of installatfon for
previously granted wastewater treatment system been required and if so, has it been submitted with
this applicatfon.
7Refer to EPA Guidance at: https://www.epa.ie/publicatfons/compliance--enforcement/waste-
water/2021_CodeofPractfce_Web.pdf
8 Refer to Water Body, Sensitfve Waters and Sensitfve Land Maps in the Monaghan County
Development Plan 2025-2031.
Abbreviations
WFD Water Framework Directfve
SAC Special Area of Conservatfon
SPA Special Protectfon Area
NHA Natural Heritage Area
EPA Environment Protectfon Agency
CEMP Constructfon Environmental Management Plan
For Office Use: Sensitivity of Location –
Is the development located upstream of a high river quality site 8?
Is the development located within a good status waterbody 8?
Is the development located in the catchment of a water supply source 8?
Is the development located within the Source Protectfon Zone (SPZ) of a groundwater supply
source 8?
Does the development require a discharge licence to surface or ground waters under the Water
Pollutfon Acts?
Risk to waters in relatfon to scale of development, previous planning/environmental history, IPPC
or EIA aspects, site management and locatfon in a sensitfve area
Applicant_______________________________
Agent:_________________________________ Date_____________
Yes
N/A
Yes
Yes
n/a
None within 100m
Michael & Margaret Wallace
Christopher Gray 31.07.2026 RECEIVED: 12/08/2026
53.17FL53.36FL53.1753.2553.2053.2353.1552.9553.1253.2553.3953.6453.1653.0852.1351.1751.3450.8150.2649.7149.5150.0048.9749.5849.2849.6950.3250.9850.0349.1548.7348.6948.9848.7748.6048.5649.0650.3451.7552.4553.2053.2952.0949.8448.6048.4848.6049.0549.1048.4948.5048.4949.1050.8352.5353.3353.0653.1953.4453.6153.6953.1852.6951.9249.9948.7048.5048.4848.4448.9349.1148.8648.5548.3848.5548.4648.8550.0951.5452.3352.9553.4952.9852.4352.0450.8549.4348.5348.4048.5048.5948.5748.7948.5948.6748.4848.5048.4648.5149.3550.4751.6552.4652.8652.9152.9452.9352.0653.0053.1353.1353.4253.5853.8352.6853.1853.1252.8752.7352.5552.2751.7351.6151.7451.7252.1350.2750.2250.5251.0552.02EPEPEPEPTop of Concrete=51.1348.4448.6348.7549.4549.8350.7351.3551.8352.0352.0951.8551.5151.2150.7350.4650.3950.3950.3850.2650.0149.6049.3749.0548.70MkrTPTPTPGGRidge Ht=58.88Ridge Ht=58.13Eave Ht=57.73Eave Ht=55.61Eave Ht=54.46PROPOSED LOCATION OFREPLACEMENT DWELLINGFFL: 53.10Ridge Ht: 62.18LOCATION OF EXISTINGSEPTIC TANKSite Area:AcresHectares0.5960.241SITE BOUNDARY IS BOUNDED IN REDExisting Ground LevelProposed Ground LevelPOST AND WIRE STOCK PROOF FENCEERECTED ALONG NEW BOUNDARIES ASDETAILED AND PLANTED IN FIRST PLANTINGSEASON AS PER PLANTING SCHEDULE (MIX A)SITE BOUNDARY OUTLINED IN REDDWELLING TO BE REPLACED (DEMOLISHED)OUTLINED IN GREENc. 2
9
m
120
m
c. 42mEXISTING AGRICULTURALENTRANCE TO REMAINUNALTEREDEXISTING AGRICULTURALENTRANCE RETAINED51.9552.4152.7152.8053.1553.0052.8052.6052.6051.9551.6051.9053.2052.1551.6552.7052.6550.8051.2051.00BITMACBITMACBITMACBITMACACO CHANNEL WITH DISCHARGE TO EXISTINGSTORM DRAINPROPOSED LOCATION OF NEW DETACHEDSINGLE STOREY DOMESTIC GARAGE:PROPOSED FINISHED FLOOR LEVEL: 53.25PROPOSED (HIGHEST) RIDGE LEVEL: 58.93VERGEVERGEVERGEVERGEBITMACBITMACLAWNT
O
E
X
I
S
T
I
N
G
S
T
O
R
M
D
R
A
I
N
DESIGNATED CONSTRUCTION STAGEWASHING BAY WITH SILT TRAPINCORPORATED ON SW SIDESILT TRAPrayCONSTRUCTION &
DESIGN
LTDdesign
planbuildCornacreeve, Dunraymond, Co. Monaghanm: 0(0353)86 0298424e:grayconstructionanddesign@gmail.comPROJECTProposed dwelling at Doagheys, Glaslough, Co.MonaghanDRAWING TITLESite Drainage PlanCLIENTMichael & Margaret WallaceDATESCALEDRAWN BY31.07.2026as indicatedCJGRECEIVED: 12/08/2026