HomeMy WebLinkAbout2660340 - Drawings - General - ElevationsELEVS F R O N T E L E V A T I O N01 Scale 1:100 FF FL_ 03.030 GF-FL_00.000 GF CL_ 02.550 RL_ 06.170 FF CL_ 05.815 34 0 0 92 5 0 ELEVS S I D E E L E V A T I O N02 Scale 1:100 FF FL_ 03.030 GF-FL_00.000 GF CL_ 02.550 RL_ 06.170 FF CL_ 05.815 61 7 0 92 5 0 ELEVS R E A R E L E V A T I O N03 Scale 1:100 FF FL_ 03.030 GF-FL_00.000 GF CL_ 02.550 RL_ 06.170 FF CL_ 05.815 61 5 0 34 0 0 FF FL_ 03.100 GF CL_ 02.650 RL_ 06.170 FF CL_ 05.850 ELEVS S I D E E L E V A T I O N04 Scale 1:100 88.5 61 7 0 92 5 0 FF FL_ 03.030 GF-FL_00.000 GF CL_ 02.550 GF-FL_-03.000 GYM/HEALTH CARE RL_ 06.170 FF CL_ 05.815 FAMILY DINING STEAM ROOM PROPOSED CUT PROPOSED FILL SECT S E C T I O N 1 - 101 Scale 1:200 6 Plantation Terrace Monaghan Co.Monaghan © copyright of mcguigan architects ltd +353 47 77823 info@mcguiganarchitects.com www.mcguiganarchitects.com Project Address Client Scale Format Status Drawn By Issue Date Drawing Title Drawing Number This drawing may not be copied or reproduced without written consent. PROPOSED DWELLING MULLANAFINNOG, EMYVALE, CO.MONAGHAN CHARLES & CLARE GRAHAM 1:100 / 1:200 A1 PLANNING TA/PMG MAY 2026 ELEVATIONS AND SECTION MGA-024-0134- PL103 --- McGUIGAN ARCHITECTS P L A N N I N G O N L Y SCHEDULE OF FINISHES: EXTERNAL WALLS STANDING SEAM ALUMINIUM NATURAL STONE TO SELECT WINDOWS ALU-CLAD DOORS COMPOSITE DOORS, COLOUR TBC CILLS PRECAST CONCRETE / ALUMINIUM ROOF STANDING SEAM ALUMINIUM RWG CONCEALED ALUMINIUM PLEASE NOTE THAT THIS IS A PLANNING DRAWING ONLY AND IS THEREFORE LIMITED IN ITS CAPACITY TO CONVEY THE TOTAL INFORMATION, DETAILS & SPECIFICATIONS NECESSARY TO COMPLETE THE WORKS. ANY WORK CARRIED OUT THAT IS NOT SPECIFIED OR DETAILED HERE WILL BE THE RESPONSIBILITY OF THE PERSONS CARRYING THEM OUT. IF ANY SITUATION ARISES WHICH WOULD CAUSE A CONTRAVENTION OF THE BUILDING REGULATIONS, THEN THE ARCHITECT SHOULD BE CONSULTED, OTHERWISE THE ARCHITECT CANNOT BE HELD RESPONSIBLE. ALL WORK AND MATERIALS ARE TO BE IN ACCORDANCE WITH CURRENT BUILDING REGULATIONS WHETHER DETAILED ON THIS DRAWING OR NOT. ALL DIMENSIONS TO BE TAKEN ON SITE - NO DIMENSIONS TO BE SCALED FROM THIS DRAWING. THIS DRAWING TO BE READ IN CONJUNCTION WITH ALL OTHER RELEVANT CONSULTANTS' DRAWINGS, SPECIFICATIONS ETC. ANY DISCREPANCIES TO BE REPORTED TO THE ARCHITECT FOR CLARIFICATION. THIS DRAWING MAY NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN CONSENT. NO WORKS SHOULD BE CARRIED OUT WITHOUT PRIOR CONSENT FROM THE LOCAL PLANNING AUTHORITY. REC E I V E D : 1 4 / 0 8 / 2 0 2 6