Loading...
HomeMy WebLinkAbout2660165 - F.I. Received Doc. - Water protection planMONAGHAN LOCAL AUTHORITIES Water Protection Plan Checklist (To be accompanied by a Site Drainage Plan - Refer to Chapter 4 of Monaghan County Development Plan 2013-2019) General Site and Water Body Details Planning Ref. No. 26/60165 Applicant Kieran & Brian Brady Townland Roosky Water Supply Source Public mains water supply X Co-ordinate 1 267369 Y Co-ordinate 1 333734 WMU 2 GBNIIENB RWB 2 Lough Neagh & Lower Bann WB Status 2 Good Objective 2 Restore 2021 Groundwater Vulnerability 3 High / Moderate (GSI mapping for Dublin Street site) Aquifer Importance 3 Rf – Regionally Important Aquifer – Fissured bedrock Proximity to nearest watercourse (culverted or open), wetland or lake (meters) >100m Proposed Development Is the development entirely or part of one of the following? (tick) Domestic dwelling Agricultural (cattle/dairy) Industrial-food related Public Works Agricultural (mushrooms) Industrial-non food Housing Agricultural (poultry) Quarrying/extracti ve industries Institutional Agricultural (piggery) Transport related Commercial/Retail ✓ Other agricultural – specify below Filling station/Fuel depot Mixed Use Development ✓ Other Waste Water Production and Treatment Method Domestic type waste waters YES – sanitary/domestic wastewater from apartments and WCs; discharge to public foul sewer. Waste waters produced from any trade, food, preparation or business 4 NO – no trade/process wastewater proposed. Wheel wash, vehicle wash, cooling waters NO Waste waters produced from quarrying etc 4 NO Other waste waters 4 NO Construction phase waste waters Temporary only – construction water to be controlled; no contaminated discharge to surface-water system. Frequently asked questions for septic tanks may assist in the “fit for purpose” assessment refer to http://www.monaghan.ie/en/services/environment/water/waterawareness/faqforseptictanks/ Fuel or Outdoor Material Storage for Non Domestic Developments Number of fuel storage tanks existing or proposed on site? 0 Are fuel storage tanks bunded 5? N/A – no fuel storage tanks proposed. Detail liquid / feedstuffs / organic / chemical / waste oil storage on outdoor sites None proposed. No outdoor chemical, waste-oil, feedstuff or organic- liquid storage associated with the development. Hard Surface and Open Yard Areas for Non Domestic Developments Footprint of proposed development including yard areas in m2 Existing developed urban site; no material increase in site footprint. Is there potential for soiled yard areas from material, product waste or manure handling, fuel dispensing, silt and soil, yard washing etc. NO – no soiled yard, fuel dispensing, manure handling or similar activity proposed. RECEIVED: 19/08/2026 If yes, are silt trap(s), interceptor(s), soiled water tanks or other control measures shown on drainage plan? N/A Has the use of SUDS (Sustainable Urban Drainage Systems – http://www.susdrain.org ) been considered in the design of this development? YES – considered. Development principally reuses existing buildings/hardstanding; existing urban drainage arrangement retained subject to drainage plan. Development History – All Developments Have previous pollution prevention planning conditions been complied with 6? no known outstanding pollution-prevention compliance issue associated with the proposed works. Does existing development have an up to date (as constructed) site drainage plan? Existing drainage arrangement to be shown on drawing 0326 / PA / 208 Is the existing/proposed development sewered or unsewered? SEWERED – foul wastewater to public foul sewer. If unsewered, is the existing wastewater treatment system fit for purpose7? N/A – no on-site wastewater treatment system proposed. Has the storm water drainage system been examined and/or surveyed for misconnections? (Information leaflet available from Environment Section) misconnections not proposed. Checklist of items to be included on Site Drainage Plan Location of lakes, watercourse, wells used for water supply, or karst features on or within 25m of domestic or 100m of non domestic development site none within relevant distance. Location of all drainage outfall points YES Foul water drainage system (in Red) YES – shown on drawing 0326 / PA / 208 Storm water drainage system (in Blue) YES – shown on drawing 0326 / PA / 208 Soiled yard area, soiled water drainage and management system, including silt traps, oil interceptor(s) and any SUDS facilities N/A – no soiled yard area proposed. Location of waste water treatment facilities N/A – no on-site wastewater treatment facility. Location of fuel storage tank(s) N/A – no fuel storage tanks. Stream/Lake/Wetland/Riparian Corridors none within relevant distance. Footnotes and Useful Information 1 Projection in the Irish Grid 2 WMU, RWB, WB status. Objectives available on water maps at www.wfdireland.ie 3 Available in the public mapping section at www.gsi.ie 4 For information leaflets on Business Premises and Proper Use of Drains and information on discharge licensing see: http://www.monaghan.ie/contentv3/services/environment/formsguidesdocumentsdownlands/ http://www.monaghan.ie/contentv3/services/environemtn/water/waterawareness/leaftletsandguidelines/ 5 Guidance: www.envirocentre.ie Best practice for Oil Storage (BPGCS05) 6 Has certification of installation for previously granted wastewater treatment system been required and if so has it been submitted. 7 Refer to EPA Guidance at: http://www.monaghan.ie/contentv3/services/environment/water/waterawareness/faqforseptictanks/ and http://www.monaghan.ie/contentv3/media/monaghanie/content/files/pdf/environment/Water Pollution&DrainageSystems.pdf 8 Refer to Water Body, Sensitive Waters and Sensitive Land Maps in Chapter 4 of the Monaghan County Development Plan 2013-2019 Abbreviations WMU Water Management Unit RWB River Water Body WB Status Water Body Status IPPC Integrated Pollution Prevention Control Licence EIA Environmental Impact Assessment For Office Use: Sensitivity of Location RECEIVED: 19/08/2026 Is the development located upstream of a high river quality site 8? Is the development located within a good status waterbody 8? Is the development located in the catchment of a water supply source 8? Is the development located within the Source Protection Zone (SPZ) of a groundwater supply source 8? Does the development require a discharge licence to surface or ground waters under the Water Pollution Acts? Risk to waters in relation to scale of development, previous planning/environmental history, IPPC or EIA aspects, site management and location in a sensitive area Applicant: Kieran & Brian Brady 11/8/26 Agent: EPA Architects Ltd. / Enda Prendergast MRIAI RECEIVED: 19/08/2026