HomeMy WebLinkAbout2660018 - F.I. Received Doc. - Wireline views to support LVIA and CH assessments landscape & VisualWireline Views to Support LVIA and CH Assessments
Landscape & Visual: VP3 - VP4 and VP8 - VP10
Cultural Heritage: CHVP1 & CHVP2RECEIVED: 28/08/2026
Visualisation Type 4 - This 90˚cylindrical projection panorama has been captured, prepared and presented in accordance with the guidance set out in the Landscape Institute Technical Guidance Note 06/19 for Type 4 Visualisations and the Scottish Natural Heritage
2017 guidance ‘Visual Representation of Wind Farms’. This image has been presented in a 90˚ cylindrical format to aid visual comprehension of linear infrastructure occupying a wide FoV, which avoids splitting the view across numerous multiple images.
90˚ Wireline View
522 mm
Horizontal Field of View: 90˚ (cylindrical projection)
Principal Distance:
Paper size:
Correct printed image size:
Enlargement Factor:
Date and Time:
Camera:
Lens:
Panoramic Head:
Camera Height:
Canon 5D Mark II Digital SLR
Canon Fixed 50mm Full Frame Sensor
Manfrotto Pano Head/Leveller
1.7m (AGL)
Photography Software:
Panorama Stitching Software:
Post-Production Software:
Formatting Software:
Modelling Software:
Rendering Software:
GNSS Unit:
Topographical Data:
GPS Ref:
Adobe Lightroom
PTGui Pro
Adobe Photoshop
Adobe Illustrator/InDesign
3DS Max 2023
Mental Ray/Corona
Trimble Catalyst (GNSS)
LiDAR/OSI Terrain Data
Georeferenced/Surveyed DWGS
14:4605/09/2024
841 x 297 mm
820 x 251 mm
96%
indicating physical position and scale of the
proposed development irrespective of screening
Proposed Development
Stream Bioenergy Ireland Ltd - RFI Photomontages to Support Landscape & Visual Assessment
L6330 local road, Drumgole townlandViewpoint Ref: VP3 819116
659727Easting ( ):
Northing ( ):
Direction of View:
Distance to Site:
Elevation:
˚
km
m
ITM
0.8
105.83
208
ITM RECEIVED: 28/08/2026
Visualisation Type 4 - This 90˚cylindrical projection panorama has been captured, prepared and presented in accordance with the guidance set out in the Landscape Institute Technical Guidance Note 06/19 for Type 4 Visualisations and the Scottish Natural Heritage
2017 guidance ‘Visual Representation of Wind Farms’. This image has been presented in a 90˚ cylindrical format to aid visual comprehension of linear infrastructure occupying a wide FoV, which avoids splitting the view across numerous multiple images.
90˚ Wireline View
522 mm
Horizontal Field of View: 90˚ (cylindrical projection)
Principal Distance:
Paper size:
Correct printed image size:
Enlargement Factor:
Date and Time:
Camera:
Lens:
Panoramic Head:
Camera Height:
Canon 5D Mark II Digital SLR
Canon Fixed 50mm Full Frame Sensor
Manfrotto Pano Head/Leveller
1.7m (AGL)
Photography Software:
Panorama Stitching Software:
Post-Production Software:
Formatting Software:
Modelling Software:
Rendering Software:
GNSS Unit:
Topographical Data:
GPS Ref:
Adobe Lightroom
PTGui Pro
Adobe Photoshop
Adobe Illustrator/InDesign
3DS Max 2023
Mental Ray/Corona
Trimble Catalyst (GNSS)
LiDAR/OSI Terrain Data
Georeferenced/Surveyed DWGS
15:5305/09/2024
841 x 297 mm
820 x 251 mm
96%
indicating physical position and scale of the
proposed development irrespective of screening
Proposed Development
Stream Bioenergy Ireland Ltd - RFI Photomontages to Support Landscape & Visual Assessment
R189 regional road, Drumcall townlandViewpoint Ref: VP4 818676
658845Easting ( ):
Northing ( ):
Direction of View:
Distance to Site:
Elevation:
˚
km
m
ITM
0
97.55
159
ITM RECEIVED: 28/08/2026
Visualisation Type 4 - This 90˚cylindrical projection panorama has been captured, prepared and presented in accordance with the guidance set out in the Landscape Institute Technical Guidance Note 06/19 for Type 4 Visualisations and the Scottish Natural Heritage
2017 guidance ‘Visual Representation of Wind Farms’. This image has been presented in a 90˚ cylindrical format to aid visual comprehension of linear infrastructure occupying a wide FoV, which avoids splitting the view across numerous multiple images.
90˚ Wireline View
522 mm
Horizontal Field of View: 90˚ (cylindrical projection)
Principal Distance:
Paper size:
Correct printed image size:
Enlargement Factor:
Date and Time:
Camera:
Lens:
Panoramic Head:
Camera Height:
Canon 5D Mark II Digital SLR
Canon Fixed 50mm Full Frame Sensor
Manfrotto Pano Head/Leveller
1.7m (AGL)
Photography Software:
Panorama Stitching Software:
Post-Production Software:
Formatting Software:
Modelling Software:
Rendering Software:
GNSS Unit:
Topographical Data:
GPS Ref:
Adobe Lightroom
PTGui Pro
Adobe Photoshop
Adobe Illustrator/InDesign
3DS Max 2023
Mental Ray/Corona
Trimble Catalyst (GNSS)
LiDAR/OSI Terrain Data
Georeferenced/Surveyed DWGS
14:0905/09/2024
841 x 297 mm
820 x 251 mm
96%
indicating physical position and scale of the
proposed development irrespective of screening
Stream Bioenergy Ireland Ltd - RFI Photomontages to Support Landscape & Visual Assessment
L2280 local road, Drumcall townlandViewpoint Ref: VP5 818142
658922Easting ( ):
Northing ( ):
Direction of View:
Distance to Site:
Elevation:
˚
km
m
ITM
0.1
111.7
73
ITM
Proposed Renewable Biogas Plant RECEIVED: 28/08/2026