Loading...
HomeMy WebLinkAbout2660030 - F.I. Received Doc. - Soil Characterisation and Site Suitability Assessment Report 1 SOIL CHARACTERISATION AND SITE SUITABILITY ASSESSMENT REPORT TE REF: 25/624 TE EIMEAR & WAYNE CASSERLY COOLMUCKBANE MONAGHAN CO. MONAGHAN IN ACCORDANCE WITH EPA CODE OF PRACTICE WASTEWATER TREATMENT AND DISPOSAL SYSTEMS SERVING SINGLE HOUSES 2021 Traynor Environmental Ltd Belturbet Business Park, Creeny, Belturbet Co. Cavan Tel: +353 49 9522236 Fax: +353 49 9522808 Web: www.traynorenvironmental.com RECEIVED: 08/09/2026 2 SITE CHARACTERISATION FORM FOR AN ON-SITE WASTEWATER TREATMENT SYSTEM CONTENTS 1.0 GENERAL DETAILS 2.0 GENERAL DETAILS 3.0 ON SITE ASSESSMENT 3.1 VISUAL ASSESSMENT 3.2 TRIAL HOLE ASSESSMENT 3.3a Subsurface Percolation Test for Subsoil Step 1 Test Hole Preparation Step 2 Pre-Soaking Test Holes Step 3 Measuring T100 Step 4 Standard Method (where T100 ≤ 210min) Step 5 Modified Method (where T100 > 210min) 3.3bSurface Percolation for Soil Step 1 Test Hole Preparation Step 2 Pre-Soaking Test Holes Step 3 Measuring T100 Step 4 Standard Method (where T100 ≤ 210min) Step 5 Modified Method (where T100 > 210min) 4.0 CONCLUSIONS OF SITE CHARACTERISATION 5.0 RECOMMENDATION 6.0 TREATMENT SYSTEM DESIGN DETAILS 7.0 SITE ASSESSORS DETAILS 8.0 PHOTOGRAPHS OF THE SITE 9.0 EPA/FAS CERTIFICATE 10.0 INSURANCE DETAILS. RECEIVED: 08/09/2026 3 1.0 GENERAL DETAILS (From planning application) Name(S) Eimear & Wayne Casserly Address of Correspondance Site Location and Townland Cornahilt Design Studio, The Grove, Ballyjamesduff, Co. Cavan Coolmuckbane, Monaghan, Co. Monaghan. Number of Bedrooms 3 Maximum Number of Residents: 5 Comments on population equivalent 5 PE is the maximum capacity of the dwelling Proposed Water Supply: Mains: Private Well/Borehole Group Well/Borehole  2.0 GENERAL DETAILS (From planning application) Soil Type, (Specify Type): Soil Association 28 Grey Brown Podzolics (60%), Gleys (20%), Interdrumlin Peat & Peaty Gleys(20%) Subsoil, (Specify Type): Sandstone till (Devonian/Carboniferous) Bedrock Type: Tournaisian sandstone, mudstone, limestone Aquifer Category: Regionally Important  Locally Important Poor Vulnerability: Extreme High  Moderate Low Groundwater Body: IEGBNI_NB_G_012 Status Not at Risk Name of Public/Group Scheme Water Supply within 1km: Unknown Source Protection Area: ZOC n/a SI n/a SO n/a Groundwater Protection Response: R21 Presence of Significant sites (Archaeological, natural and historical): None evident within the locality Past experience in the area: Variable percolation characteristics of the topsoil and subsoil materials. R21 = Acceptable subject to normal good practice. Site may be suitable for discharge to ground, if the minimum depths are met on the site and if there exists suitable percolation. As the soil type in the area is Grey Brown Podzolics (60% of the land area), and as the area is mapped as ‘High’ Vulnerability. Groundwater as a resource will be at risk if the minimum depths required are not achieved on the site, or if the percolation rate is too rapid. Older wells in the area may also be at risk, if the minimum separation distances are not adhered to. Groundwater and wells are therefore the main targets, following the desk study. Given the response and the aquifer type, the site is potentially suitable for a conventional septic tank system if the minimum depths required are met on the site, if the minimum separation distances can be met, and if the percolation rate is adequate. ____________________________________________________________________________________ 1This figure of 5 people refers to the potential 5 people maximum that will stay at the proposed dwelling at any one time. RECEIVED: 08/09/2026 4 3.0 ON-SITE ASSESSMENT 3.1 Visual Assessment Landscape Position Relatively Flat Slope Steep <1:5 Shallow 1.5 to 1.20 Relatively Flat  Slope Comment Relatively Flat Surface features within a minimum of 250 metres (Distances to features should be noted in metres) Houses Proposed dwelling to be located >10m Southeast from the proposed percolation area (ppa). Neighbouring dwellings located >10m Southwest from the ppa. Neighbouring dwellings also located 40m North, 60m,100m, & 140m East and 210m Southeast from the ppa. Existing Land Uses Agricultural Grassland Vegetation Indicators Grass is the predominant vegetation throughout the site. Groundwater Flow Directions South Direction Ground Condition Ground conditions are best described as dry and firm through-out the site in the ppa. Site Boundaries Existing Hedge located to the West from the ppa. Fenceline & Road located to the North, dwelling & street area located to the South and East of the ppa. Roads L1402located >4m North from the ppa. Outcrops (Bedrock and/or subsoil) Some outcropping rock evident within the locality. Surface water ponding No surface water ponding evident in the ppa when examined on 22.10.25. It must be noted that weather conditions prior to the site assessment taking place was generally mild conditions. Lakes None occur within 50m of the ppa. Beaches/Shellfish Areas None occur within 200m of the ppa. Wetlands None occur within 200m of the ppa. Karst Features None occur within 200m of the ppa. Watercourses/Streams None occur within 10m of the ppa. Drainage Ditches None occur within 10m of the ppa. Springs If a well is to be bored onsite it should be located at least 30m up-gradient from the ppa; this will therefore be outside the minimum separation distances of the Groundwater Protection Responses of GSI/EPA/DoELG and the EPA Code of Practice (2021). As all the wells in the locality will therefore meet the RECEIVED: 08/09/2026 5 required separation distances of the Groundwater Protection Responses of GSI/EPA/DoELG and the EPA Code of Practice (2021), none are deemed to be at risk from the proposed polishing filter’s installation. As all the wells in the locality will therefore meet the required separation distances of the Groundwater Protection Responses of GSI/EPA/DoELG and the EPA Code of Practice (2021), none are deemed to be at risk from the proposed polishing filter’s installation. Integrate the information above in order to comment on: 1. The potential suitability of the site: The site still seems suitable for discharge to ground. 2. Potential targets at risk: Following the desk study surface water was thought not to be at risk; this was corroborated during the visual assessment. There appears to be few issues with respect to impermeability. From this, surface water does not seem to be a potential target, Groundwater is still a target following the visual assessment, unless the minimum depths required are met on the site and there exists adequate percolation. 3. The suitability of the site to treat the wastewater: Following the visual assessment, it is seen that all appropriate separation distances can be met and the site seems well drained, and pending confirmation of the presence of adequate depths of unsaturated soil and subsoil within the percolation area, as well as sufficient percolation rates under the site, the site should be suitable for treating wastewater adequately. RECEIVED: 08/09/2026 6 Sketch of site showing measurement to Trial Hole location and Percolation test Hole locations, wells and direction of ground water flow, proposed house (incl. distances from boundaries) adjacent houses, watercourses, significant sites and other features. North point should always be included. SITE LAYOUT DRAWING SHOWING TEST HOLE LOCATIONS Groundwater Flow Direction Approximate Location of Trial Hole & Percolation Test Holes Examined on 22.10.2025 .19 RECEIVED: 08/09/2026 7 3.2 Trial Hole Should be a minimum 2.10m deep Depth of Trial Hole 2.10m BGL Depth from Ground Surface to bedrock (m) if Present None Encountered Depth from Ground Surface to Water Table (m) if Present 1.80m Depth of water ingress 1.80m Rock Type if Present None Encountered Date and Time of Excavation 20.10.2025 09.00 Date and Time of Examination 22.10.2025 10.15 Depth of Subsurface & Surface Soil/Subsoil Texture Classification Plasticity and Dilatancy Soil Structure Density Compactness Colour Preferential Flowpaths 0.1m Depth of Silt/Clay Ribbons Crumb Low/Medium Brown Silt/Clay 0.2m Surface 30.30.40 0.3m Test 2,2,2Threads 0.4m 0.5m Depth of Clay intermixed Ribbons Blocky Medium Brown 0.6m Subsurface Test With stone 60.70.80 0.7m 2,3,3Threads 0.8m 0.9m 1.0m 1.1m 1.2m 1.3m 1.4m 1.5m 1.6m 1.7m 1.8m 1.9m GWT GWT GWT GWT GWT GWT 2.0m 2.1m 2.2m EVALUATION: Weather conditions: Mild According To The Flowchart For Describing Subsoil’s based on BS5930:1999, the subsoil is best described as Clay intermixed with stone Groundwater was encountered in the trial hole at 1.80m BGL. Winter groundwater was not encountered in the trial hole. Bedrock was not encountered in the trial hole. Likely Subsurface Percolation Value: <50.00 min /25mm *Note: Depth of percolation test holes should be indicated on log above (Enter Subsurface & Surface Depths as appropriate) * See Appendix E for BS5930 Classification ** 3 samples to be tested *** All signs of mottling should be recorded. Likely Surface Percolation Value: <50.00 min /25mm RECEIVED: 08/09/2026 8 3.3a Subsurface Percolation Test for Subsoil Step 1 Test Hole Preparation Percolation Test Hole 1 2 3 Depth from ground surface to top of hole (mm) (A): 150 150 150 Depth from ground surface to base of hole (mm) (B): 550 550 550 Depth of hole (mm) (B-A): 400 400 400 Dimensions of hole [length x breadth (mm)]: 300 x 300 300 x 300 300 x 300 Step 2 Pre-Soaking Test Holes Pre-soak start Date 21.10.2025 21.10.2025 21.10.2025 Time 11.10 11.11 11.12 2nd pre-soak start Date 21.10.2025 21.10.2025 21.10.2025 Time 17.20 17.21 17.22 Each hole should be pre-soaked twice before the test is carried out. Each hole should be empty before refilling. Step 3 Measuring T100 Percolation Test Hole 1 2 3 Date of Test 22.10.2025 22.10.2025 22.10.2025 Time Filled to 400mm 10.14 10.16 10.18 Time Water Level at 300mm 12.35 13.02 12.58 Time to drop 100mm (T100) 141.00 166.00 160.00 Average T100 155.67 If T100 >480mins then Subsurface Percolation value >120 – site unsuitable for discharge to ground If T100 ≤ 210mins then go to Step 4 If T100 ≥ 210mins then go to Step 5 RECEIVED: 08/09/2026 9 Step 4 Standard Method (where T100 ≤ 210min) Percolation Test Hole 1 2 3 Fill No. Start Time at 300mm Finish Time at 200mm ∆t (min) Start Time at 300mm Finish Time at 200mm ∆t (min) Start Time at 300mm Finish Time at 200mm ∆t (min) 1 12.36 15.07 151.00 13.03 16.01 178.00 12.59 13.50 171.00 2 15.08 17.53 165.00 16.02 19.05 183.00 13.51 16.57 186.00 3 17.54 20.56 182.00 19.06 22.26 200.00 16.58 20.15 197.00 Average ∆t 166.00 187.00 184.67 Average ∆t/4 = [Hole No. 1] 41.50 Average ∆t/4 = [Hole No. 2] 46.75 Average ∆t/4 = [Hole No. 2] 46.17 Result of Test: Subsurface Percolation Value: 44.81 min/25mm Result of Test: Subsurface Percolation Value = 44.81 min/25mm. Comments Average Percolation Characteristics of the Subsoil Material. RECEIVED: 08/09/2026 10 3.3bSurface Percolation for Soil Step 1 Test Hole Preparation Percolation Test Hole 1 2 3 Depth from ground surface to top of hole (mm) (A): 0 0 0 Depth from ground surface to base of hole (mm) (B): 400 400 400 Depth of hole (mm) (B-A): 400 400 400 Dimensions of hole [length x breadth (mm)]: 300 x 300 300 x 300 300 x 300 Step 2 Pre-Soaking Test Holes Pre-soak start Date 21.10.2025 21.10.2025 21.10.2025 Time 11.14 11.15 11.17 2nd pre-soak start Date 21.10.2025 21.10.2025 21.10.2025 Time 17.25 17.27 17.30 Each hole should be pre-soaked twice before the test is carried out. Each hole should be empty before refilling. Step 3 Measuring T100 Percolation Test Hole 1 2 3 Date of Test 22.10.2025 22.10.2025 22.10.2025 Time Filled to 400mm 10.20 10.22 10.25 Time Water Level at 300mm 12.24 12.31 12.41 Time to drop 100mm (T100) 124.00 129.00 136.00 Average T100 129.67 If T100 >480 minutes then Surface Percolation value >90 – site unsuitable for discharge to ground If T100 ≤ 210mins then go to Step 4 If T100 ≥ 210mins then go to Step 5 RECEIVED: 08/09/2026 11 Step 4 Standard Method (where T100 ≤ 210min) Percolation Test Hole 1 2 3 Fill No. Start Time at 300mm Finish Time at 200mm ∆t (min) Start Time at 300mm Finish Time at 200mm ∆t (min) Start Time at 300mm Finish Time at 200mm ∆t (min) 1 12.25 14.33 128.00 12.32 14.48 136.00 12.42 15.50 143.00 2 14.34 16.50 136.00 14.49 17.15 146.00 15.51 18.22 151.00 3 16.51 19.18 147.00 17.16 19.57 161.00 18.23 21.09 166.00 Average ∆t 137.00 147.67 153.33 Average ∆t/4 = [Hole No. 1] 34.25 Average ∆t/4 = [Hole No. 2] 36.92 Average ∆t/4 = [Hole No. 2] 38.33 Result of Test : Surface Percolation Value 36.50 min/25mm Result of Test: surface Percolation Value = 36.50min/25mm. Comments Average Percolation Characteristics of the Topsoil Material. RECEIVED: 08/09/2026 12 4.0 CONCLUSIONS of SITE CHARACTERISATION: Integrate the information from the desk study and on-site assessment (i.e. visual assessment, trial hole and percolation tests) above and conclude the type of system(s) that is (are) appropriate. This information is also used to choose the optimum final disposal route of the treated wastewater. Slope of Proposed Infiltration/treatment area 1.200 Are all minimum separation distance met? Yes Depth of unsaturated soil and/or subsoil beneath invert of gravel (or drip tubing in the case of drip dispersal system) 0.90m Percolation test results: Surface: 36.50 min/25mm Sub-surface: 44.81 min/25mm Not suitable for Development Suitable for Development  Identify all suitable options Discharge Route 1. Septic tank System (Septic tank and percolation area) (Chapter 7) Groundwater 2. Secondary Treatment System (Chapters 8 and 9) and soil polishing filter (Section 10.1)  3. Tertiary Treatment System and Infiltration/treatment area (Section 10.2)  5.0 RECOMMENDATION: Propose to install Traynor Environmental recommends an Tricel EN Treatment system or similar EN Certified System, Ter3 Pod and soil polishing filter is constructed in accordance with EPA guidelines 2021. And discharge to Groundwater Invert level of the trench/bed gravel or drip tubing (m) 0.30m Below Ground Level (BGL) Site Specific Conditions (if any) e.g. special works, Site Improvement Works, Testing etc. The tests showed that the site has a Sub-surface value rating of 44.81 min/25mm indicating adequate percolation characteristics of the Sub-surface. A surface value rating of 36.50 min/25mm was attained indicating adequate percolation characteristics of the surface. Groundwater was encountered in the trial hole at 1.80m BGL. Bedrock was not encountered in the trial hole. An Ter3 pod should be constructed to ensure that there is a minimum of 0.90m of suitable percolating material between the base of the lowest part of the Gravel Distribution Bed and Groundwater at all times. The Ecoflo Co Co Filter will be bedded on 300mm depth of crushed stone (20-30mm in sizes). Traynor Environmental Ltd also recommends that the Tricel Treatment System, Ter3 Pod and polishing filter construction is overseen by a suitable qualified and accredited person. RECEIVED: 08/09/2026 13 6.0 TREATMENT SYSTEM DETAILS SYSTEM TYPE: Septic Tank System (Chapter 7) Tank Capacity (m2) N/A Percolation Area Mound Percolation Area No. of Trenches N/A No. of Trenches N/A Length of Trenches (m) N/A Length of Trenches (m) N/A Invert Level (m) N/A Invert Level (m) N/A SYSTEM TYPE: Secondary Treatment System (Chapters 8 and 9) and polishing filter (Section 10.1) Secondary Treatment Systems receiving septic tank effluent (Chapter 8) Package Treatment Systems Media Type Area (m2) Deep of Filter (m) Invert Level (m) receiving raw wastewater (Chapter 9) Sand/Soil N/A N/A N/A Type Tricel P6 Treatment System Soil N/A N/A N/A Capacity PE 6 Constructed Wetland N/A N/A N/A Sizing of Primary Compartment Other N/A N/A N/A 4 m2 Polishing Filter: (Section 10.1) Surface Area Sand Filter (m2) Ter3 Pod No. of Trenches N/A Option 1 – Direct Discharge Surface area (m2) 75 Length of Trenches (m) N/A Option 2 – Pumped Discharge Surface Area (m2) N/A Invert Level (m) 0.30m AGL SYSTEM TYPE: O’Reilly Oakstown Treatment System and infiltration/ treatment area (section 10.2) Identify purpose of tertiary treatment Provide performance information demonstrating system will provide required treatment levels Provide design information Tricel Treatment System, Ter3 Pod & Gravel Distribution Bed DISCHARGE ROUTE: Groundwater  Hydraulic Loading Rate (l/m2. d) 750 Surface Area (m2) Surface Water Discharge Rate (m3/hr) 0.009 QUALITY ASSURANCE: Installation & Commissioning On-going Maintenance Recommend to be overseen by plant supplier. Maintain and de-sludge annually RECEIVED: 08/09/2026 14 7.0 SITE ASSESSOR DETAILS Company: Traynor Environmental Ltd Prefix: Mr. First Name: Nevin Surname: Traynor Address: Belturbet Business Park, Creeny, Belturbet, Co. Cavan. Qualifications/Experience: BSc. Env, H.Dip I.T, Cert SHWW, EPA/FAS Course Certified Professional Indemnity Insurance Holder (€1 million cover) Date of Report: 01.09.2026 PI/1 (Renewed 12th July 2026) Signed: Nevin Traynor BSc. Env, H.Dip I.T, Cert SHWW, EPA/FAS Cert. For Traynor Environmental Ltd RECEIVED: 08/09/2026 15 8.0 SITE PHOTOGRAPHS Facing East From the Proposed Percolation Area Facing South From the Proposed Percolation Area Facing West From the Proposed Percolation Area Facing North From the Proposed Percolation Area Trial Hole – Front View Trial Hole – Side View RECEIVED: 08/09/2026 16 Percolation (“T”) Test 1 Percolation (“T”) Test 2 Percolation (“T”) Test 3 Percolation (“P”) Test 1 Percolation (“P”) Test 2 Percolation (“P”) Test 3 RECEIVED: 08/09/2026 17 Maps Used As Part of the EPA Site Suitability Assessment Groundwater/Aquifer Map From the GSI Groundwater Aquifer Map Site is classified as Rf - Regionally Important Aquifer - Fissured bedrock Vulnerability Map From the GSI Vulnerability Map Site is classified as High RECEIVED: 08/09/2026 18 Bedrock Map From the GSI Bedrock Map Site is classified Tournaisian sandstone, mudstone, limestone Teagasc Subsoil Map From the Teagasc Subsoil Map Site is classified as Sandstone till (Devonian/Carboniferous) RECEIVED: 08/09/2026 19 9.0 EPA/FAS CERTIFICATE RECEIVED: 08/09/2026 20 10.0 P.I INSURANCE RECEIVED: 08/09/2026 21 PROPOSAL FOR A TRICEL TREATMENT SYSTEM PREPARED FOR EIMEAR & WAYNE CASSERLY COOLMUCKBANE MONAGHAN CO. MONAGHAN RECEIVED: 08/09/2026 TRAYNOR ENVIRONMENTAL LTD EPA SEWAGE LOADING SIZING CHART - EIMEAR & WAYNE CASSERLY Situation Source Litres/day BOD5 g/d PE Organic Number of Population Hydraulic Organic Pupulation Person Person Loading Persons (Organic)Loading (Lit)Loading (gr)(Hydraulic) Domestic Normal Resident 150 60 1.00 5 5 750 300 5.00 Industrial Office and/or factory without canteen 30 20 0.33 0 0 0 0.00 Office and/or factory with canteen 60.0 30.0 0.5 0 0 0 0.00 Open Industrial Site e.g. Quarry 40.0 25.0 0.4 0 0 0 0.00 School Non- residential with cooking on-site Students 60.0 30.0 0.5 0 0 0 0.00 6hr Shock Non-residential with no-cooking on site 35 20 0.33 0 0 0 0.00 Football clubs Players incl. showers 30 20 0.33 0 0 0 0.00 Spectators - Toilet blocks 8 10 0.17 0 0 0 0.00 Amenity Sites Restuarants 15 15 0.25 0 0 0 0.00 Function rooms 10 10 0.17 0 0 0 0.00 Toilet blocks (per use)8 10 0.17 0 0 0 0.00 Toilet blocks (long stay car parks)10 15 0.25 0 0 0 0.00 Golf clubs 25 15 0.25 0 0 0 0.00 Squash, with club house 25 15 0.25 0 0 0 0.00 Swimming 10 10 0.17 0 0 0 0.00 5 750 300 5.00 Loadings Population Org 5.00PE Hydraulically 5.00PE Treatment System Proposed: Tricel P6Treatment System, Ter3 & Gravel Distribution Bed RECEIVED: 08/09/2026 For Single Dwellings & Small Communities Tricel ® Novo WASTEWATER TREATMENT Innovative design for superior performance IRELAND RECEIVED: 08/09/2026 What is the Tricel Novo Key features & benefits Tricel Novo wastewater treatment plants are reliable, easy to install and simple to maintain for all wastewater requirements. These highly functional plants can cater for ranges from 1 to 50 PE (population equivalents). The Tricel Novo submerged aeration plant is suitable for domestic and light commercial or communal applications and uses simple proven fixed bed technology. Each system comprises of 3 independent treatment zones, all fulfilling a different stage of the purification process. ►Compression moulded SMC tank. The compression moulding process is one of the most technologically developed processes available to manufacture structural composites. Components are manufactured under heat and high pressure and have unrivalled strength and durability over standard GRP tanks or Polyethylene tanks. ►SMC is unique in the wastewater treatment industry with Tricel SMC tanks operating in some of the harshest climatic conditions for over 50 years with no defects. ►Tricel’s ceramic diffuser is unique in the domestic wastewater treatment plant market and will last twice as long as all standard competitors rubber equivalents. This saves money in both call out fees and replacement parts. ►No concrete backfill for installation on most sites saving up to €400 over lower quality GRP or Polyethylene alternatives from competitors. ►No moving parts or pumps in the plant ensuring reliable operation and minimal maintenance and repair costs. ►Tricel Novo plants are designed with a shallow invert to reduce both installation and time costs. + 353 (0) 64 6632421 sales@tricel.ie Call us Today for a Free Quote How a Tricel Novo works These plants use a simple, proven technology, consisting of 3 treatment zones. In each zone a different stage of the treatment occurs. 1. Wastewater from the dwelling, toilets, sinks, shower etc., enters the plant. 2. Effluent enters the primary settlement chamber. Settlement occurs when the heavier solids drop out of the wastewater and settle to the bottom of the tank to create sludge, and the lighter solids float to the top of the water to create a scum. The top layer acts as a seal and stops odours escaping. This chamber separates up to 70% of the solids present. 3. Next is the aeration chamber, where masses of naturally occurring bacteria inhabit specially designed plastic filter media. The bacteria feed on the waste removing it from the liquid. A continues supply of air from a low pressure, high volume compressor in the top section of the unit sustains these bacteria. Wastewater passes through the filter media over and over, ensuring a very high treatment efficiency. 4. The liquid then proceeds to the final settlement chamber. Any remaining minute bacterial particles separate from the liquid within this chamber before discharge from the plant. This process slows the liquid’s velocity, allowing for any final trace impurities to settle to the bottom of the tank section. A sludge return system then returns these impurities back to the primary settlement chamber. 5. The remaining treated liquid now meets the required standard and is safely passed out of the Tricel Novo plant system. The treated effluent is now ready for discharge to a suitably designed discharge area as required by the relevant local authority. Tricel Novo Wastewater Treatment Plant has an overall efficiency of 95.9% BOD removal All Tricel wastewater treatment plants have been tested to European certification EN 12566–3 and comply with the requirements of S.R. 66:2015. This certification tests all plants for strength, water tightness, durability and treatment efficiency. By using a wastewater treatment plant which is CE certified clients can rest assured that it has complied with tests and inspections which guarantee a high level of security and efficiency. European Certification Requirements RECEIVED: 08/09/2026 Homeowners: Individual domestic installation Larger projects: Commercial installations up to 50PE Technical characteristics/ Plant dimensions ►These plants are suitable for installation at housing estates, camping sites, hotels etc., and have low maintenance and running costs. ►Each WWTP unit is constructed of lightweight SMC and is easy to manoeuvre which simplifies the installation process. ►The lightweight nature of the system makes for easy on-site delivery. ►No need for big excavators and large holes that disrupt and disturb your garden. ►Very low visual impact from fully installed units. ►Example of a fully installed 50PE Novo Wastewater Treatment Plant (WWTP) in a 5-star hotel. 1375 535 1300 610 2100 330Ground Level 1375 535 1660 250 2100 330Ground Level ►IE6 gravity outlet Up to 6PE domestic gravity flow outlet. ►IE6 pumped outlet 1-6 domestic pumped unit. Suitable for pumping to a raised discharge area (over). ►IE50 gravity outlet Suitable for commercial installation, caters for up to 50 people. Tricel Novo riser options for deep installation Tricel offer 3 different manhole riser heights to suit different invert/inlet levels. Manhole risers allow for the positioning of the treatment plants at the depth which is optimum to each individual installation.Wastewater is gravity fed from the home to your treatment plant. The inlet pipe’s position from the premises determines the excavation depth for the WWT plant. Tricel offer a choice of manhole risers 250mm/500mm/750mm to help with installation where site conditions require a flexible solution. Novo Design Population No. of people Length Width Height Nominal inlet/ outlet diameter Weight empty Inlet invert to base Outlet invert to base Inlet invert to ground level Air blower rating (Mean) m mm kg m watts IE6 1-6 2.1 1.64 2.24 110 270 1.375 1.3 0.535 70 IE6+*2-6 2.6 1.64 2.24 110 300 1.375 1.3 0.535 70 IE8 2-8 2.6 1.64 2.24 110 300 1.375 1.3 0.535 86 IE10 3-10 3.1 1.64 2.24 110 370 1.375 1.3 0.535 86 IE12 4-12 3.6 1.64 2.27 110 400 1.375 1.3 0.535 100 IE18 6-18 4.6 1.64 2.27 110 500 1.375 1.3 0.535 215 IE24 8-24 6.6 1.64 2.27 150 700 1.35 1.3 0.56 215 IE30 Tank A 10-30 2.6 1.64 1.99 150 300 1.35 1.3 0.46 Tank B 5.6 1.64 2.27 150 600 1.35 1.3 0.56 215 + 86 IE36 Tank A 12-36 3.6 1.64 1.99 150 400 1.35 1.3 0.46 Tank B 6.6 1.64 2.27 150 700 1.35 1.3 0.56 215 + 86 IE42 Tank A 14-42 5.6 1.64 2.27 150 600 1.35 1.3 0.46 Tank B 5.6 1.64 2.27 150 600 1.35 1.3 0.56 215 x 2 IE50 Tank A 16-50 6.6 1.64 2.27 150 700 1.35 1.3 0.46 Tank B 6.6 1.64 2.27 150 700 1.35 1.3 0.56 215 + 130 + 86 1300 360 6600 1350 560 VENT 250 Ground Level 1300 510 460 6600 1350 460 Ground Level 610 16401640 WEIGHT:700KGWEIGHT:700KG TANK A TANK B PART NO: REV. NO. DRAWN: TANK REVISION: COUNTRY : DATEBY SCALE SIZE UNITS: PRINTED COPIES OF THIS DOCUMENT ARE UNCONTROLLED UNLESS STATED OTHERWISE PRODUCT NAME: SALES SPECIFICATION DRWG NO: TOLERANCE: MATERIAL: WEIGHT: ISSUE DATE::TRICEL (KILLARNEY) UNLIMITED COMPANY RESERVES THE RIGHT TO CHANGE THE SPECIFICATION WITHOUT PRIOR NOTIFICATION. 123 D 123 4 4 5 5 6 6 A A B B C C D 12 D N/ANR +/-5 GRP 16/11/2016 Novo IE50 Gravity IRELAND MILLIMETERS 700 kg+700 kg 00.00 AE TGIE5001 0000 18/11/16 1300 360 6600 1350 560 VENT 250 Ground Level 1300 510 460 6600 1350 460 Ground Level 610 16401640 WEIGHT:700KGWEIGHT:700KG TANK A TANK B PART NO: REV. NO. DRAWN: TANK REVISION: COUNTRY : DATEBY SCALE SIZE UNITS: PRINTED COPIES OF THIS DOCUMENT ARE UNCONTROLLED UNLESS STATED OTHERWISE PRODUCT NAME: SALES SPECIFICATION DRWG NO: TOLERANCE: MATERIAL: WEIGHT: ISSUE DATE::TRICEL (KILLARNEY) UNLIMITED COMPANY RESERVES THE RIGHT TO CHANGE THE SPECIFICATION WITHOUT PRIOR NOTIFICATION. 123 D 123 4 4 5 5 6 6 A A B B C C D 12 D N/ANR +/-5 GRP 16/11/2016 Novo IE50 Gravity IRELAND MILLIMETERS 700 kg+700 kg 00.00 AE TGIE5001 0000 18/11/16RECEIVED: 08/09/2026 In accordance with Tricel’s normal policy of product development these specifications are subject to change without notice. Tricel (Killarney) Unlimited Company trading as Tricel Tricel, Ballyspillane Industrial Estate, Killarney, Co Kerry, Ireland Tel: +353 (0) 64 6632421 | Email: sales@tricel.ie | www.tricel.ie 1103464/04-IRE-Nov2024Tricel Group Tricel is a world recognised global provider of high-performance solutions. Today, the company operates across multiple industries such as Environmental, Construction, Water and Distribution, including both composite materials and lubricants. We occupy a unique position in the field of reinforced plastics, combining the technical expertise of over 60 years in the press-moulding and composites industry. Tricel is proud of being one of the largest manufacturers of wastewater treatment plants in Europe, and are regarded by regulators as the standard setters within the industry. Tricel are experts in Sheet Moulding Compound (SMC) processes and produce the only wastewater treatment plant in Europe constructed from this material. This process gives the highest strength to thickness ratio of any tank on the market, and has no risk of corrosion over time. Our company offers industry leading innovative solutions that our customers can trust, and with operations in 17 locations across Europe we supply a comprehensive range of products to over 50 countries worldwide. Membership of European governing bodies on wastewater treatment The Tricel Environmental Waste Water Treatment Plants are fully tested and accredited to European standards for CE certification. PIA (Prüfinstitut für Abwassertechnik GmbH) are the leading Test Institute in Europe for wastewater technology. Tricel Wastewater treatment plants meet with EN12566-3 requirements which test both the quality of the components as well as the overall performance of the plant. The Irish Water Treatment Association (IWTA) is the national association for the treatment, conservation, recycling and reuse of water and wastewater. The Irish Onsite Wastewater Association (IOWA) formed in 2007 with the goal of improving the standard of professionalism in the on-site treatment of wastewater in Ireland. PIA-SR66-1512-1062 • The warranty period for mechanical parts within the products is 12 months from the date of purchase. This includes the compressor, control panel, ceramic diffuser and all internal components. • The SMC structure of the tanks carry a 10 year warranty from date of purchase. • All products are CE certified to EU safety, health and environmental requirements. WARRANTY - IRELAND ONLY 00 353 (0) 64 663242100 353 (0) 64 6632421 sales@tricel.iesales@tricel.ie All warranties are subject to correct installation and use of the product, including maintenance as per manufacturer guidelines RECEIVED: 08/09/2026 Certification En12566/3 as listed on https://www.pia-gmbh.com/en/component/jdownloads/send/9-packaged-treatment-plants/245-tpw- systems-eurotank-baf2-ter3-pdf -- For Irish Use RECEIVED: 08/09/2026 Certification En12566/7 RECEIVED: 08/09/2026 RECEIVED: 08/09/2026 RECEIVED: 08/09/2026 RECEIVED: 08/09/2026 RECEIVED: 08/09/2026 RECEIVED: 08/09/2026 RECEIVED: 08/09/2026 RECEIVED: 08/09/2026 RECEIVED: 08/09/2026 RECEIVED: 08/09/2026 RECEIVED: 08/09/2026 RECEIVED: 08/09/2026 RECEIVED: 08/09/2026 RECEIVED: 08/09/2026 RECEIVED: 08/09/2026 RECEIVED: 08/09/2026 RECEIVED: 08/09/2026 RECEIVED: 08/09/2026