Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2660030 - F.I. Received Doc. - Site layout plan
Location of site notice. Area in red to indicate site boundary. New entrance walls piers and gates Fenceline to boundary Dwelling to which application relates. Finished floor level +100.000 All water from site to be collected along 4 m set back and run to soakaway Surface water from roof water and landscape hard standing & site entrance run off to be collected in land drain pipe and suitable soakaway to be formed to engineers design Location of surface water soakaway. Ex. boundary hedge no change Connection to group water New Sewage treatment system Site area 3500 sqm Maintain Ho u s i n g C l u s t e r L i n e Parents Dwelling 12380 4500 5600 560 15690 761091002820209007980171802198040004100 Ex. boundary hedge no change Ex. boundary hedge no change Domestic Garage to which application relates.New Sewage treatment system for adjoining house see engineers report 10020111209460 27890 21810 18910 +100.000 STN +99.830 +99.760 +99.730 +100.110 +100.080 +100.310 +99.950 +99.760 +99.8202400 90050 90000 Sight line 90m Sight line 90m kevinoneill1984@yahoo.ie NORTH POINT KEVIN O' NEILL, BSc (HONS) ARCH TECH, THE GROVE, BALLYJAMESDUFF,CO.CAVAN Http://kevinoneill.carbonmade.com DRAWING NO TITLE PROJECT PROJECT NO REV DATE SCALE @ A3 DRAWN CHECK REV CLIENT KEY Plan Proposed Proposed NOTES © Kevin O' Neill DO NOT SCALE DRAWING cornahilt design studio. NOTES: © Cornahilt Design Studios Ltd. DO NOT SCALE DRAWING Planning Drawings only Not for construction or Tender. Cladding systems and Fire Safety Design by others Cornahilt Design Studios Ltd do not design Cladding systems or are not responsible for Fire Stopping or any Fire related sign off. Survey for planning only Contractor to check all dimensions. N/A & Wayne Casserly KONN/A- 1:500/250 -001 Contiguous Elevations Site Plan & Coolmuckbane, Co. Monaghan 2521 North Site Plan01 Scale 1:500 Further InformationRECEIVED: 08/09/2026 TV Room Dining Room Living Room 105 SQM Shower Room Utility Plant Pantry Bedroom Bedroom Playroom Master Bedroom W-in-W W-in-W E.S Bathroom Shoe/VanityWardrobe2.1m Height2.1m Height102 SQM Ground Floor Plan First Floor Plan Lobby Store (Drawers to Living space)2000Lvl +100.000 1385 21551100 2150277038504475 2700 7980121555175 4320 4175408030404355 31801850205038504475 31801100280036305215 798012375 121555175 41756700 H.P 12375 8875 7280518016002380 Porch Sliding Door Lvl +100.000 Kitchen T.V 3635 4200 4675 4380HiddenPantryDoordesign guidelines as set out in Table 15.3 ‘Guidelines for Siting and Designing a Rural House in the Vernacular Style’. In this regard, the Planning Authority has the following Guidelines, ‘External gable depth should not exceed 9m (6.5m for narrow plan form)’ window types are of concern. As per the Design Guidelines, ‘window openings should 41755007980 79804175500 Ground Floor Plan 01 Scale 1:100 kevinoneill1984@yahoo.ie NORTH POINT KEVIN O' NEILL, BSc (HONS) ARCH TECH, THE GROVE, BALLYJAMESDUFF,CO.CAVAN Http://kevinoneill.carbonmade.com DRAWING NO TITLE PROJECT PROJECT NO REV DATE SCALE @ A3 DRAWN CHECK REV CLIENT KEY Plan Proposed Proposed NOTES © Kevin O' Neill DO NOT SCALE DRAWING cornahilt design studio. NOTES: © Cornahilt Design Studios Ltd. DO NOT SCALE DRAWING Planning Drawings only Not for construction or Tender. Cladding systems and Fire Safety Design by others Cornahilt Design Studios Ltd do not design Cladding systems or are not responsible for Fire Stopping or any Fire related sign off. Survey for planning only Contractor to check all dimensions. N/A & Wayne Casserly KONN/A- 1:100/200 -002 Plans Ground, First & Roof Coolmuckbane, Co. Monaghan 2521 First Floor Plan 02 Scale 1:100 Roof Plan 03 Scale 1:200NorthNorthNorth Further InformationRECEIVED: 08/09/2026 +0.000 FFL Lvl FFL: +3.000 Roof Lvl FFL: +7.135 7135FFL Lvl FFL: +5.450 Selected Slate Roof Selected Glazing Selected Stone Finish Selected finish soffit fasica and downpipes +0.000 FFL Lvl FFL: +3.000 Roof Lvl FFL: +7.135 7135FFL Lvl FFL: +5.450 Selected Slate Roof Selected Glazing Selected Stone Finish Selected finish soffit fasica and downpipes +0.000 Roof Lvl FFL: +7.135 FFL Lvl FFL: +3.000 7135FFL Lvl FFL: +5.450 Selected Slate Roof Selected Glazing Selected finish soffit fasica and downpipes +0.0007135Selected Glazing Selected finish soffit fasica and downpipes Selected Render Finish FFL Lvl FFL: +3.000 Roof Lvl FFL: +7.135 FFL Lvl FFL: +5.450 kevinoneill1984@yahoo.ie NORTH POINT KEVIN O' NEILL, BSc (HONS) ARCH TECH, THE GROVE, BALLYJAMESDUFF,CO.CAVAN Http://kevinoneill.carbonmade.com DRAWING NO TITLE PROJECT PROJECT NO REV DATE SCALE @ A3 DRAWN CHECK REV CLIENT KEY Plan Proposed Proposed NOTES © Kevin O' Neill DO NOT SCALE DRAWING cornahilt design studio. NOTES: © Cornahilt Design Studios Ltd. DO NOT SCALE DRAWING Planning Drawings only Not for construction or Tender. Cladding systems and Fire Safety Design by others Cornahilt Design Studios Ltd do not design Cladding systems or are not responsible for Fire Stopping or any Fire related sign off. Survey for planning only Contractor to check all dimensions. N/A & Wayne Casserly KONN/A- 1:100 -003 Proposed Elevations Coolmuckbane, Co. Monaghan 2521 Front Elevation 01 Scale 1:100 Rear Elevation 02 Scale 1:100 Side Elevation03 Scale 1:100 Further InformationRECEIVED: 08/09/2026 Living RoomStudy Bedroom Bedroom 2600245062551590+0.000 FFL Lvl FFL: +3.000 Roof Lvl FFL: +7.135 FFL Lvl FFL: +5.450 +0.000 FFL Lvl FFL: +3.000 Roof Lvl FFL: +7.135 7135FFL Lvl FFL: +5.450 Selected Slate Roof Selected Glazing Selected finish soffit fasica and downpipes kevinoneill1984@yahoo.ie NORTH POINT KEVIN O' NEILL, BSc (HONS) ARCH TECH, THE GROVE, BALLYJAMESDUFF,CO.CAVAN Http://kevinoneill.carbonmade.com DRAWING NO TITLE PROJECT PROJECT NO REV DATE SCALE @ A3 DRAWN CHECK REV CLIENT KEY Plan Proposed Proposed NOTES © Kevin O' Neill DO NOT SCALE DRAWING cornahilt design studio. NOTES: © Cornahilt Design Studios Ltd. DO NOT SCALE DRAWING Planning Drawings only Not for construction or Tender. Cladding systems and Fire Safety Design by others Cornahilt Design Studios Ltd do not design Cladding systems or are not responsible for Fire Stopping or any Fire related sign off. Survey for planning only Contractor to check all dimensions. N/A & Wayne Casserly KONN/A- 1:100 -004 Elevations Proposed Coolmuckbane, Co. Monaghan 2521 Section A-A01 Scale 1:100 Side Elevation 02 Scale 1:100 Further InformationRECEIVED: 08/09/2026