HomeMy WebLinkAbout2560414 - F.I. Maps - Site LayoutPassag
e
W
a
y
LEGEND
Site Boundary
Existing Levels
New Hard Surface Driveway
NOTES:
Proposed planting to be carried out in the first planting season following commencement
of building operations and permanently retained thereafter.
Any plant which fails in the first year of planting will be replaced straight away.
Existing mature boundary,
Native trees and hedging
Proposed Native hedge Plant in a staggered double
row at five plants per metre.115.00 M approx.
141.24
LANDSCAPING LEGEND
Existing Site Visibility Splays (70m achieved)
Site Notice
14
.
3
7
M
24
.
4
9
M
9.1
M
7.87 M
9.66 M
6.5
9
M
7.71 M
7.72 M
2.21 M
0.5
M
0.72 M
0.32 M
0.6
2
M
Lane To Development/Retention
The Hollow Road
Castle
b
l
a
y
n
e
y
To N
2
Feeding Silo
Existing Entrance
To Be Closed Off
Existing Hedges and Trees Surrounding Site
Existing Dwelling
Shed Shaded
For Retention
Feeding Silo
Area for Retention Shaded
mo
r
n
i
n
g
su
n
mid-day
sun
ev
e
n
i
n
g
su
n
2.8
9
M
2.8
9
M
1.07 M
70M Sight Splays
7.42
M
Road
Proposed Entrance To Site
Proposed Laneway
2 a
.
m
.
1 a
.
m
.
12
a
.
m
.
11
p
.
m
.
10
p
.
m
.
9 p.m
.
8 p.m.
7 p.m.
6 p.m.
5 p.m.
4 p.m.
3 p.m
.
2 p
.
m
.
1 p
.
m
.
12
p
.
m
.
11
a
.
m
.
10
a
.
m
.
9 a.m
.
8 a.m.
7 a.m.
6 a.m.
5 a.m.
4 a.m.
3 a.m
.
MID-WI NTER SUN
MID-SUMMER SUN
N
Area of site
outlined in red
0.5504 HA
SITE LAYOUT PLAN
SCALE 1:500
Road
Channel In Concrete
Directing Dirty Water
To Tanks
Concrete Yard Falling
To Channel Concrete
Yard To Soakway
Cattle Crush
SOAKAWAY
Falls
Falls
FallsClean Surface
Water Runoff
Collected
Existing Entrance To be
Closed Off And New
Entrance To Be Used
To Acsess Yard & Farm Turning Space For HGVs
FL
FL
IC
IC
POST
POST
POST
POST
POST
POST
POST
POST
POST
POST
POST
POST
1
120.62
2
123.00
3
122.48
4
122.93
122.54122
.
4
4
123
.
5
0
122.
3
7
123.
2
4
122.10
121.
8
8
121.8
0
121.37
121.33121.25
122.62
121.98
121.53
121.51
121.17
120.97
120.52
120.05
119.43
118.82
119.11
119.66
120.17
120.54
120.58
120.95
121.23
121.10
121.75
122.31
123.12
124.18
125.49
126.71
12
1
.
7
8
12
2
.
5
1
123
.
0
1
12
1
.
9
6
122
.
3
1
122.74
122.89
123.06
123.14
123.12
123.12
123.02
122.93
122.81
122.96
123.04
122.94
122.77
122.76
122.93
123.01
122.63
122.67
122.67
122.61
122.53
123.03
123.72
123.65
123
.
7
1
12
3
.
7
3
12
3
.
7
4
12
3
.
7
4
123.72
125.24125.39
125
.
2
3
12
5
.
2
3
122.96
122.95
122.23
122.42
122.
6
8122
.
4
1
122
.
3
6
122.
9
9
122.53 122
.
5
7
123
.
8
6
123
.
6
3
122.95
123
.
4
0
122.
6
4
122.74122.76
122.70
123.08
129.96=Silo
126.5
4
=
R
L
126.0
2
=
E
L
127.3
5
=
R
L
126.1
4
=
E
L
127.7
1
=
R
L
130.42=Silo
125.65=RL
124.2
5
=
C
I
L
L
125.4
2
=
H
E
A
D
126.17=Door ht
125.61=Door ht
12
5
.
9
6
=
C
I
L
L
12
7
.
1
6
=
H
E
A
D
12
7
.
1
9
=
H
E
A
D
12
6
.
1
1
=
C
I
L
L
122.
0
123
.
0
CH
A
N
N
E
L
FE
N
C
E
FE
N
C
E
FE
N
C
E
FEN
C
E
FEN
C
E
FENCE
CONC
R
E
T
E
BUILDINGS
STORE
CONCRETE
IC
POST
WM
120.58
111.4
7
112.6
8
114.
3
2
115.
5
7
117.
2
3
121.90
123.84
124.03
123.65
123.81
122.37
122.00
121.22
120.07
120.26
119.03
118.86
118.17
118.10
116.58
116.57
114.35
114.77
113.70
112.54
112.72
111.40
110.62
110.28
110.30
110.16
109.92
109.73
110.02
110.48
110.69
111.69
111.07
110.50
110.81
112.19
112.60
111.84
124.13
124.27
124.74
123.56
123.64
124.32
124.50
124.30
124.03
123.71
123.22
122.31
122.09
122.54
122.58
122.80
122.91
123.00
123.31
123.19
123.03
124.00
124.21
124.21
123.81
124.28
124.11
123.69
123.84
123.45
123.75
116.25
115.
2
5
114.
3
4
113.
3
3
123
.
5
123
.
5
123
.
0
12
2
.
5
122
.
5
12
2
.
0
12
2
.
0
12
1
.
5
12
1
.
0
12
0
.
5
119
.
0
12
0
.
0
119
.
5
118
.
5
11
8
.
0
11
7
.
5
11
7
.
0
11
6
.
5
11
6
.
0
11
5
.
5
11
5
.
0
11
4
.
5
110
.
5
11
1
.
0
11
3
.
0
112
.
5
112.
0
111.
5
110.
0
12
4
.
5
124
.
0
124.0
12
4
.
0
123
.
0
12
3
.
5
11
3
.
5
11
4
.
0
RIAIC M D
ARCHITECTS
REVISIONJOB NUMBER
SCALE
CHECKED
DWG NUMBER
DRAWING
JOB
CLIENT
DWG. SERIES
Registered
Architect
PSDP
Accreditation
2025 P
info@cmdarchitects.ie042 9743754t e042 9743755t
CMD Architects Limited,Thornford Lodge, Broomfield, Castleblayney, Co.Monaghan
DrnDate DescriptionRev
DATE
DRN
Do not scale from this drawing. Use figured dimensions in all cases. Verify dimensions on site and report any discrepancies to the architects immediately.
This drawing to be read in conjunction with the architects specification. This drawing is copyright and may only be reproduced with the architects permission.
PLANNING - FI
STEPHEN & PATRICIA KELLY
RETENTION AT CARICKAGARVAN CASTLEBLANEY
SITE LOCATION PLAN
1.500
OC
25-244 001.00
09.09.2026
REC
E
I
V
E
D
:
1
0
/
0
9
/
2
0
2
6