HomeMy WebLinkAbout2660399 - Site assessment reportSITE SUITABILITY ASSESSMENT PETER HOLLAND CLONES CO MONAGHAN IN ACCORDANCE WITH: EPA CODE OF PRACTICE WASTEWATER TREATMENT AND DISPOSAL SYSTEM SERVING SINGLE HOUSES 2021 PREPARED BY: AARON MC BENNETT Bsc Env Sc REC E I V E D : 1 6 / 0 9 / 2 0 2 6 SITE CHARACTERISATION FORM COMPLETING THE FORM Section 3.2 In this section use an underline _____ across all six columns to indicate the depth at which changes in classification / characteristics occur. Section 3.4 Lists supporting documentation required. Section 4 Select the treatment systems suitable for this site and the discharge route. Section 5 Indicate the system type that it is proposed to install. Section 6 Provide details, as required, on the proposed treatment system. Notes: All calculations in this form are automatic. Where possible information is presented in the form of drop down selection lists to eliminate potential errors. Variable elements are recorded by tick boxes. In all cases only one tick box should be activated. All time record fields must be entered in twenty four hour format as follows: HH:MM All date formats are DD-MM-YYYY. All other data fields are in text entry format. This form can be printed out fully populated for submission with related documents and for your files. It can also be submitted by email. Step 1: Goto Menu Item File, Save As and save the file under a reference relating to the client or the planning application reference if available. Use the Clear Form button to clear all information fields. Note: This form requires the latest version of Adobe Acrobat Reader and on PC’s Windows 7 or later. Windows XP produces errors in calculations. Note: To secure your work prior to forwarding to third parties please select Print, select Printer “print to PDF” and name and save document. REC E I V E D : 1 6 / 0 9 / 2 0 2 6 2.0 GENERAL DETAILS (From planning application) Soil Type, (Specify Type): Subsoil, (Specify Type): Bedrock Type: Aquifer Category: Regionally Important Locally Important Poor Vulnerability: Extreme High Moderate Low Groundwater Body: Status Name of Public/Group Scheme Water Supply within 1 km: Source Protection Area: ZOC SI SO Groundwater Protection Response: Presence of Significant Sites (Archaeological, Natural & Historical): Past experience in the area: Comments: (Integrate the information above in order to comment on: the potential suitability of the site, potential targets at risk, and/or any potential site restrictions). Note: Only information available at the desk study stage should be used in this section. APPENDIX A: SITE CHARACTERISATION FORM File Reference: 1.0 GENERAL DETAILS (From planning application) Prefix: First Name: Surname: Address: Site Location and Townland: Number of Bedrooms: Maximum Number of Residents: Comments on population equivalent Proposed Water Supply: Mains Private Well/Borehole Group Well/Borehole Mr Peter Holland 4 6 The proposed dwelling is a 4 bed which can cater for a maximum of 6 persons at any one time. 4 BminPD - Mineral poorly drained (Mainly basic) General Soil Map No- 14 (Acid Brown Earths 75%, Gleys 15%, Brown Podzolics 10%) TLs-Till derived chiefly from limestone Visean limestone & calcareous shale Rk 4 IEGBNI_NW_G_030 None R1 None within 250m Soakage tests carried out in the general area shows different infiltration rates The site initially seems suitable to discharge to ground. The soil type in the area is dominated by Grey Brown Podzolics (60%). Groundwater as a recourse will be at risk if separation distances are not adhered to due to the 'High' Vulnerability. Groundwater Protection Response is R1 - Acceptable subject to normal good practice. Site may be suitable for discharge to ground, if the minimum depths are met on the site and if there exists suitable percolation. Groundwater and wells are therefore the main targets following the desk study. Given the response and the aquifer type, the site is suitable for a conventional septic tank system if the minimum depths required are met on the site, if the minimum separation distances can be met. To be bored on-site Good REC E I V E D : 1 6 / 0 9 / 2 0 2 6 3.0 ON-SITE ASSESSMENT 3.1 Visual Assessment Landscape Position: Slope: Steep (>1:5) Shallow (1:5-1:20) Relatively Flat (<1:20) Slope Comment Surface Features within a minimum of 250m (Distance To Features Should Be Noted In Metres) Houses: Existing Land Use: Vegetation Indicators: Groundwater Flow Direction: Ground Condition: Site Boundaries: Undulating Rolling Landscape 4 in soil polishing filter area Neighboring houses are located >180m south from the proposed soil polishing filter. Agricultural Grassland There are no vegetation indicators within 250m of the proposed soil polishing filter . Grassland is the predominant vegetation within the area & throughout the proposed soil polishing filter area. Northern Direction The area of the site where tested was carried out was dry & firm underfoot. No poaching was observed throughout the site Hedges bound the site to the west of the proposed soil polishing filter. Field is located to the North, south east of the proposed soil polishing filter. REC E I V E D : 1 6 / 0 9 / 2 0 2 6 3.0 ON-SITE ASSESSMENT 3.1 Visual Assessment (contd.) Roads: Outcrops (Bedrock And/Or Subsoil): Surface Water Ponding: Lakes: Beaches/Shellfish Areas: Wetlands: Karst Features: Watercourses/Streams:* *Note and record water level Local road is located approximately 200m south from the proposed soil polishing filter. No outcrops with identified within 250m from the proposed soil polishing filter. No surface water occurred within 250m of the proposed soil polishing filter at the time of assessment. The majority of the land in this area is on a gradient. Rose Lough is located >100m north from the proposed soil polishing filter. None within 250m of the proposed soil polishing filter. None within 250m of the proposed soil polishing filterr. None within 250m of the proposed soil polishing filter. None within 10m of the proposed soil polishing filter. REC E I V E D : 1 6 / 0 9 / 2 0 2 6 Comments: (Integrate the information above in order to comment on: the potential suitability of the site, potential targets at risk, the suitability of the site to treat the wastewater and the location of the proposed system within the site). *Note and record water level 3.0 ON-SITE ASSESSMENT 3.1 Visual Assessment (contd.) Drainage Ditches:* Springs:* Wells:* None within 10m of the proposed soil polishing filter. None within 250m of the proposed soil polishing filter. A well is to be bored on site it shall be located >30m up gradient from the proposed soil polishing filter. This will ensure it is outside the minimum separation distance of the groundwater protection response according the EPA Code of Practice 2021. As all the wells in the locality will therefore meet the required separation distances of the Groundwater Protection Responses of GSI/EPA/DoELG and the EPA Code of Practice (2021), none are deemed to be at risk from the proposed polishing filter’s installation. The site will be suitable to discharge to ground if a pocket of acceptable soil with sufficient depth can be located within the area of the proposed polishing filter. During the visual assessment it became clear that the site was well drained . There are no signs of impermeable soils throughout the site. Surface water around the site does not seem to be a potential target unless the soil within the proposed polishing filter is found to be saturated within 0.50m BGL (Below Ground Level). Wells in the area are not considered to be at risk as none occur within the minimum separation distance of the groundwater protection response GSI/EPA/DoELG and the EPA Code of Practice 2021.The proposed treatment unit and soil polishing filter are to be installed exactly where specified in this Soil Characterisation report. Following the visual assessment, I decided to dig the test holes on the southern proportion of the site. The land here is firm and dry underfoot REC E I V E D : 1 6 / 0 9 / 2 0 2 6 3.2 Trial Hole (should be a minimum of 2.1m deep (3m for regionally important aquifers)) Depth of trial hole (m): Depth from ground surface Depth from ground surface to bedrock (m) (if present): to water table (m) (if present): Depth of water ingress: Rock type (if present): Date and time of excavation: Date and time of examination: Depth of Surface and Subsurface Soil/Subsoil Percolation Texture & Plasticity and Soil Density/ Colour**** Preferential Tests Classification** dilatancy*** Structure Compactness flowpaths 0.1 m 0.2 m 0.3 m 0.4 m 0.5 m 0.6 m 0.7 m 0.8 m 0.9 m 1.0 m 1.1 m 1.2 m 1.3 m 1.4 m 1.5 m 1.6 m 1.7 m 1.8 m 1.9 m 2.0 m 2.1 m 2.2 m 2.3 m 2.4 m 2.5 m 2.6 m 2.7 m 2.8 m 2.9 m 3.0 m 3.1 m 3.2 m 3.3 m 3.4 m 3.5 m Likely Subsurface Percolation Value: Likely Surface Percolation Value: Note: *Depth of percolation test holes should be indicated on log above. (‘Enter Surface or Subsurface at depths as appropriate). ** See Appendix E for BS 5930 classification. *** 3 samples to be tested for each horizon and results should be entered above for each horizon. **** All signs of mottling should be recorded. To avoid any accidental damage, a trial hole assessment or percolation tests should not be undertaken in areas which are at or adjacent to significant sites, (e.g. NHAs, SACs, SPAs, and/or Archaeological etc.), without prior advice from National Parks and Wildlife Service or the Heritage Service. 2.10 N/A N/A N/A N/A 04-May-2026 10:00 06-May-2026 10:45 S1-3 SS1-3 SILT/CLAY SILT/CLAY & stones Mottling @1.70m BGL Base of Hole @2.10m BGL 1,1,2 threads 30mm,30mm, 40mm ribbons dilatant raspy 2,2,2 threads, 40mm,50mm,50m m ribbons, dilatant raspy Crumb Crumb Low Medium Brown Brown 20-26 12-18 REC E I V E D : 1 6 / 0 9 / 2 0 2 6 3.3(a) Subsurface Percolation Test for Subsoil x x x 3.2 Trial Hole (contd.) Evaluation: Step 1: Test Hole Preparation Percolation Test Hole 1 2 3 Depth from ground surface to top of hole (mm) (A) Depth from ground surface to base of hole (mm) (B) Depth of hole (mm) [B - A] Dimensions of hole [length x breadth (mm)] Step 2: Pre-Soaking Test Holes Pre-soak start Date Time 2nd pre-soak Date start Time 2 3 Each hole should be pre-soaked twice before the test is carried out. Step 3: Measuring T100 Percolation Test Hole No. 1 Date of test Time filled to 400 mm Time water level at 300 mm Time (min.) to drop 100 mm (T100 ) Average T100 If T100 > 480 minutes then Subsurface Percolation value >120 – site unsuitable for discharge to ground If T100 ≤ 210 minutes then go to Step 4; If T100 > 210 minutes then go to Step 5; The upper 0.40m of the trial hole profile consists of a brown soft to firm soil. (A Horizon) The brown subsoil (0.40m –1.30m) consists of SILT/CLAY with occasional stone This soil will allow draining to take place vertically or sub vertically into the subsoil. (B Horizon) Both A & B Horizons are free draining, and no mottling was evident. The 'C' horizon beneath the soil extends to the water table at 1.70m depth and is a soft to firm, 300 700 400 300 700 400 300 700 400 300 300 300 300 300 300 05-May-2026 10:15 05-May-2026 14:20 05-May-2026 10:15 05-May-2026 14:22 05-May-2026 10:15 05-May-2026 14:26 06-05-2026 10:30 11:45 75.00 06-05-2026 10:30 11:56 86.00 06-05-2026 10:30 12:10 100.00 3 87.00 REC E I V E D : 1 6 / 0 9 / 2 0 2 6 Result of Test: Subsurface Percolation Value = (min/25 mm) Step 4: Standard Method (where T100 ≤ 210 minutes) Percolation Test Hole 1 2 3 Fill no. Start Finish ∆t (min) Start Finish ∆t (min) Start Finish ∆t (min) Time Time Time Time Time Time (at 300 (at 200 (at 300 (at 200 (at 300 (at 200 mm)mm)mm)mm)mm)mm) 1 2 3 Average ∆t Value Average ∆t/4 = Average ∆t/4 = Average ∆t/4 = [Hole No.1](t1) [Hole No.2](t2) [Hole No.3](t3) Result of Test: Subsurface Percolation Value = (min/25 mm) Comments: Comments: Percolation Test Hole No.1 Fall of water Time Start Finish Time Kfs T – in hole (mm) Factor Time Time of fall = Tf Value = Tf hh:mm hh:mm (mins) / Tm = 4.45 = Tm / Kfs 300 - 250 8.1 250 - 200 9.7 200 - 150 11.9 150 - 100 14.1 Average T- Value T- Value Hole 1 = (T1 ) Step 5: Modified Method (where T100 > 210 minutes) Percolation Test Hole No.2 Fall of water Time Start Finish Time Kfs T – in hole (mm) Factor Time Time of fall = Tf Value = Tf hh:mm hh:mm (mins) / Tm = 4.45 = Tm / Kfs 300 - 250 8.1 250 - 200 9.7 200 - 150 11.9 150 - 100 14.1 Average T- Value T- Value Hole 2 = (T2 ) Percolation Test Hole No.3 Fall of water Time Start Finish Time Kfs T – in hole (mm) Factor Time Tim§e of fall = Tf Value = Tf hh:mm hh:mm (mins) / Tm = 4.45 = Tm / Kfs 300 - 250 8.1 250 - 200 9.7 200 - 150 11.9 150 - 100 14.1 Average T- Value T- Value Hole 3 = (T2) 11:46 13:08 82.00 13:09 14:37 88.00 14:38 16:12 94.00 88.00 22.00 11:57 13:29 92.00 13:30 15:06 96.00 15:07 16:50 103.00 97.00 24.25 12:11 13:57 106.00 13:58 15:53 115.00 15:54 17:57 123.00 114.67 28.67 3 24.97 SS1, SS2 & SS3 confirm the make up of the subsoil of SILT/CLAY with stones. All holes where empty the morning off the tests prior to 2 pre-soakings in the days previous .Theses test support the observations makes on the trial holes visual assessment in relation to the texture and drainage classes. 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 2 0.00 REC E I V E D : 1 6 / 0 9 / 2 0 2 6 3.3(b) Surface Percolation Test for Soil Step 1: Test Hole Preparation Percolation Test Hole 1 2 3 Depth from ground surface to top of hole (mm) Depth from ground surface to base of hole (mm) Depth of hole (mm) Dimensions of hole [length x breadth (mm)] Step 2: Pre-Soaking Test Holes Pre-soak start Date Time 2nd pre-soak Date start Time Each hole should be pre-soaked twice before the test is carried out. Step 3: Measuring T100 Percolation Test Hole No. 1 2 3 Date of test Time filled to 400 mm Time water level at 300 mm Time to drop 100 mm (T100 ) Average T100 If T100 > 480 minutes then Surface Percolation value >90 – site unsuitable for discharge to ground If T100 ≤ 210 minutes then go to Step 4; If T100 > 210 minutes then go to Step 5; x x x 0 400 400 0 400 400 0 400 400 300 300 300 300 300 300 05-May-2026 10:25 05-May-2026 14:35 05-May-2026 10:25 05-May-2026 14:35 05-May-2026 10:25 05-May-2026 14:35 06-May-26 10:35 11:12 37.00 06-May-26 10:35 11:26 51.00 06-May-2026 10:35 11:38 63.00 50.333 REC E I V E D : 1 6 / 0 9 / 2 0 2 6 Step 4: Standard Method (where T100 ≤ 210 minutes) Percolation Test Hole 1 2 3 Fill no. Start Finish ∆T (min) Start Finish ∆T (min) Start Finish ∆T (min) Time Time Time Time Time Time (at 300 (at 200 (at 300 (at 200 (at 300 (at 200 mm)mm)mm)mm)mm)mm) 1 2 3 Average ∆T Value Average ∆T/4 = Average ∆T/4 = Average ∆T/4 = [Hole No.1](T1 ) [Hole No.2](T2 ) [Hole No.3](T3 ) Result of Test: Surface Percolation Value = (min/25 mm) Comments: (min/25 mm) Comments: Percolation Test Hole No.1 Fall of water Time Start Finish Time Kfs T – in hole (mm) Factor Time Time of fall = Tf Value = Tf hh:mm hh:mm (mins) / Tm = 4.45 = Tm / Kfs 300 - 250 8.1 250 - 200 9.7 200 - 150 11.9 150 - 100 14.1 Average T- Value T- Value Hole 1 = (T1 ) Step 5: Modified Method (where T100 > 210 minutes) Percolation Test Hole No.2 Fall of water Time Start Finish Time Kfs T – in hole (mm) Factor Time Time of fall = Tf Value = Tf hh:mm hh:mm (mins) / Tm = 4.45 = Tm / Kfs 300 - 250 8.1 250 - 200 9.7 200 - 150 11.9 150 - 100 14.1 Average T- Value T- Value Hole 2 = (T2 ) Result of Test: Surface Percolation Value = Percolation Test Hole No.3 Fall of water Time Start Finish Time Kfs T – in hole (mm) Factor Time Time of fall = Tf Value = Tf hh:mm hh:mm (mins) / Tm = 4.45 = Tm / Kfs 300 - 250 8.1 250 - 200 9.7 200 - 150 11.9 150 - 100 14.1 Average T- Value T- Value Hole 3 = (T2) 11:13 11:55 42.00 11:56 12:44 48.00 12:45 13:41 56.00 48.67 12.17 11:27 12:21 54.00 12:22 13:23 61.00 13:24 14:37 73.00 62.67 15.67 11:39 12:44 65.00 12:45 13:56 71.00 13:57 15:12 75.00 70.33 17.58 15.14 S1, S2 & S3 confirm the make up of the SILT/CLAY in the top layer . All holes where empty the morning off the tests prior to 2 pre-soakings in the days previous .Theses test support the observations makes on the trial holes visual assessment in relation to the texture and drainage classes. 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 3 0.00 0.002 REC E I V E D : 1 6 / 0 9 / 2 0 2 6 3.4 The following associated Maps, Drawings and Photographs should be appended to this site characterisation form. 1 The calculated percolation area or polishing filter area should be set out accurately on the site layout drawing in accordance with the code of practice’s requirements. 1. Discovery Series 1:50,000 Map indicating overall drainage, groundwater flow direction and housing density in the area. 2. Supporting maps for vulnerability, aquifer classification, soil, subsoil, bedrock. 3. North point should always be included. 4.(a) Scaled sketch of site showing measurements to Trial Hole location and (b)Percolation Test Hole locations, (c) wells and (d) direction of groundwater flow (if known), (e) proposed house (incl. distances from boundaries) (f)adjacent houses, (g)watercourses, (h)significant sites (i)and other relevant features. 5. Site specific cross sectional drawing of the site and the proposed layout1 should be submitted. 6. Photographs of the trial hole, test holes and site including landmarks (date and time referenced). 7. Pumped design must be designed by a suitably qualified person. REC E I V E D : 1 6 / 0 9 / 2 0 2 6 Integrate the information from the desk study and on-site assessment (i.e. visual assessment, trial hole and percolation tests) above and conclude the type of system(s) that is (are) appropriate. This information is also used to choose the optimum final disposal route of the treated wastewater. Slope of proposed infiltration / treatment area: Are all minimum separation distances met? Depth of unsaturated soil and/or subsoil beneath invert of gravel (or drip tubing in the case of drip dispersal system) Percolation test result: Surface: Sub-surface: Not Suitable for Development Suitable for Development Identify all suitable options Discharge Route 1 1.Septic tank system (septic tank and percolation area) (Chapter 7) 2.Secondary Treatment System (Chapters 8 and 9) and soil polishing filter (Section 10.1) 3.Tertiary Treatment System and Infiltration / treatment area (Section 10.2) 4.0 CONCLUSION of SITE CHARACTERISATION 5.0 SELECTED DWWTS Propose to install: and discharge to: Invert level of the trench/bed gravel or drip tubing (m) Site Specific Conditions (e.g. special works, site improvement works testing etc. 1 A discharge of sewage effluent to “waters” (definition includes any or any part of any river, stream, lake, canal, reservoir, aquifer, pond, watercourse or other inland waters, whether natural or artificial) will require a licence under the Water Pollution Acts 1977-90. Refer to Section 2.4. 1:200 4 0.90 15.14 24.97 4 No Yes Yes Groundwater through soil polishing filter Secondary Treatment System and soil polishing filter Ground Water -0.50 Tests show that the site has a sub-surface value of 24.97min/25mm and a surface value of 15.14min/25mm.These results are good and the ground is proven to be permeable. Mottling was encountered in the trial hole at a depth of 1.70m BGL. A polishing filter shall be constructed to ensure that there is a minimum of 900mm of suitable percolating soil beneath the lowest part of the percolation at all times. Pipes used for the system shall be smooth walled, with a diamater off 100mm, and have 8mm holes drilled in them 75mm apart. Each pipe should be spaced parallel to one another and 2500mm centre to centre.It is recommended that the treatment system and polishing filter construction is overseen by a suitably qualified and accredited person. All works are to comply fully with EPA Code of Practice 2021. I, Aaron Mc Bennett will supervise the installation of the No.1 O'Reilly Oakstown Treatment System & Soil Polishing Filter.All works shall be carried out in accordance with EPA Code of Practice 2021. When the O'Reilly Oakstown Treatment System & Soil Polishing Filter are installed I will provide a certificate of compliance. I am fully qualified to carry out such work as I hold a degree in Bsc Environmental Science and I also hold a QQI award in 'Site Suitability for Wastewater Treatment'. I am insured to 1,000,000 euros. Certificate and insurance cover is attached in appendix. REC E I V E D : 1 6 / 0 9 / 2 0 2 6 SYSTEM TYPE: Septic Tank Systems (Chapter 7) Tank Capacity (m3) Percolation Area Mounded Percolation Area No. of Trenches No. of Trenches Length of Trenches (m) Length of Trenches (m) Invert Level (m) Invert Level (m) SYSTEM TYPE: Secondary Treatment System (Chapters 8 and 9) and polishing filter (Section 10.1) Secondary Treatment Systems receiving septic tank effluent Packaged Secondary (Chapter 8) Treatment Systems receiving raw wastewater (Chapter 9) Media Type Area (m2)* Depth of Filter Invert Level Type Sand/Soil Soil Capacity PE Constructed Wetland Sizing of Primary Compartment Other m3 Polishing Filter*: (Section 10.1) Surface Area (m2)* Option 1 - Direct Discharge Surface area (m2) Option 2 - Pumped Discharge Surface area (m2) DISCHARGE ROUTE: Groundwater Hydraulic Loading Rate * (l/m2.d) Surface area (m2) Surface Water ** Discharge Rate (m3/hr) 6.0 TREATMENT SYSTEM DETAILS * Hydraulic loading rate is determined by the percolation rate of subsoil ** Water Pollution Act discharge licence required Identify purpose of tertiary treatment Option 3 - Gravity Discharge Trench length (m) Option 4 - Low Pressure Pipe Distribution Trench length (m) Option 5 - Drip Dispersal Surface area (m2) SYSTEM TYPE: Tertiary Treatment System and infiltration / treatment area (Section 10.2) Provide performance information demonstrating system will provide required treatment levels Provide design information 80m(10Nox8m )300 -0.50m BGL O' Reilly Oakstown WWTP 8 4.00 O'Reilly Oakstown Treatment System & Soil Polishing Filter 4 900.00 REC E I V E D : 1 6 / 0 9 / 2 0 2 6 Company: Prefix: First Name: Surname: Address: Qualifications/Experience: Date of Report: Phone: E-mail Indemnity Insurance Number: Signature: ________________________________________ 7.0 SITE ASSESSOR DETAILS 6.0 TREATMENT SYSTEM DETAILS QUALITY ASSURANCE: Installation & Commissioning On-going Maintenance To secure your work prior to forwarding to third parties please select Print, select Printer “print to PDF” and name and save document. NOTE: Installation to be supervised by a competent individual with professional indemnity insurance. A completion report should be supplied to the homeowner which records the onstallation process and details. Desludging of the proposed plant should be as per table 12.2 of the EPA code of Practice (2021), or when scum in observed in the second chamber of the tank, or when the depth of sludge in the second compartment is greater than 0.40m. Mr Aaron Mc Bennett Corvoy, Ballybay, Co Monaghan Bsc Environemtal Science,QQI award 'Site Suitability for Wastewater Treatment' 8 yr experience 18-Jun-2026 0870697709 aaronmcbennett83@gmail.com PI/EN13064064 REC E I V E D : 1 6 / 0 9 / 2 0 2 6 DISCOVERY MAPS Figure 1 – Location of the site at Cavan, Clones, Co Monaghan marked with a red circle Figure 2 – From the Discovery Series 1:50,000 maps shows the groundwater flow direction of the site. Groundwater flows towards Rose Lough to the lower ground in the northern direction. Site Marked Using Red Circle Groundwater Flow Direction REC E I V E D : 1 6 / 0 9 / 2 0 2 6 Site Layout Showing Percolation Test Location Groundwater Flow Direction Location of Trial Hole, Sub- Surface & Surface Tests Carried out on 06.05.2026 Groundwater Flow Direction also indicated REC E I V E D : 1 6 / 0 9 / 2 0 2 6 CALCULATING HYDRAULIC LOADING & SIZING OF SOIL POLISHING FILTER Situation: Domestic Development Litres/day/person: 150 BOD5 grams/day/person: 60 PE Organic Loading per person: 1.00 Number of Person: 6 (Based of 4-bedroom house) Total Population Organic: 6 (Number of persons (6) x PE Organic Loading (1) Total Hydraulic Loading (Litres): 900 (Number of persons (6) x Litres/day/person (150) Total Organic Loading (Grams): 360 (Number of persons (6) x BOD5 grams/day/person (60) Total Population Hydraulic: 6 How to calculate soil polishing filter size: The soil polishing filter size is determined depending on the sub-surface value. This value is then put into a range of sizes using table 10.1 below. In our case the Subsurface value was 24.97min/25mmGravity discharge into 500mm wide trenches (option 3) was the most suitable for this site. 12m per person is what is required with the subsurface value that was achieved. 12m x 6 people = 72m of trenches required. Maximum Trench length =10m 72m /10m = 7.2 lengths (rounded up to 8 lengths for ease of construction) Soil polishing filter will consist of – 10 No x 8m lengths See below table 10.1 marked in red how his value was calculated. REC E I V E D : 1 6 / 0 9 / 2 0 2 6 GEOSCIENTIFIC MAPS Groundwater/Aquifer Map From the GSI Groundwater Aquifer Map Site is classified as Rk-Regionally Important Aquifer - Karstified- Vulnerability Map From the GSI Vulnerability Map Site is classified as – High REC E I V E D : 1 6 / 0 9 / 2 0 2 6 Teagasc Subsoil Map From the Teagasc Subsoil Map Site is classified as TLs Till derived chiefly from limestone Geology Bedrock Map From the GSI Geology Bedrock Map Site is classified as Visean limestone & calcareous shale REC E I V E D : 1 6 / 0 9 / 2 0 2 6 SITE PHOTOGRAPHS Stand Facing West From Trial Hole Excavation Area Stand Facing South From Trial Hole Excavation Area Stand Facing North From Trial Hole Excavation Area Stand Facing East From Trial Hole Excavation Area REC E I V E D : 1 6 / 0 9 / 2 0 2 6 Trial Hole- Side View Trial Hole- Front View Soil Removed from Soakaway test hole. Soil is soft and well aerated. Presence of stones and gravel indicated that the soil will allow water to pass through easily REC E I V E D : 1 6 / 0 9 / 2 0 2 6 Sub- Surface Hole 1 Prior to Testing Sub- Surface Hole 2 Prior to Testing Sub- Surface Hole 3 Prior to Testing Surface Hole 1 Prior to Testing Surface Hole 2 Prior to Testing Surface Hole 3 Prior to Testing REC E I V E D : 1 6 / 0 9 / 2 0 2 6 Testing of Sub- Surface Hole 1 Testing of Sub- Surface Hole 1 Testing of Sub- Surface Hole 3 Testing of Surface Hole 1 Testing of Surface Hole 2 Testing of Surface Hole 3 REC E I V E D : 1 6 / 0 9 / 2 0 2 6 QQI 'SITE SUITABILITY FOR WASTEWATER TREATMENT' AWARD REC E I V E D : 1 6 / 0 9 / 2 0 2 6 PI INSURANCE REC E I V E D : 1 6 / 0 9 / 2 0 2 6 SOIL POLISHING DESIGN AREA REC E I V E D : 1 6 / 0 9 / 2 0 2 6 10000 Vent Min 900mm of suitable unsaturated soil 300mm Pea Gravel Bed Ø100mm Percolation Pipe 150mm Pea Gravel Geotextile Membrane Ground Level Treatment System to be located >7m from the dwelling house Proposed Soil Polishing Filter to be located >10 from the dwelling house NOTE: Pipe to fall at a gradient of 1:200 Topsoil Min Depth 300mm Mottling @ 1.70m Below Ground Level Base Of Trail Hole 2.10m Mottling @ 1.70m Below Ground Level Min 900mm of suitable unsaturated soil 300mm Pea Gravel Bed Ø100mm Percolation Pipe 150mm Pea Gravel Geotextile Membrane Vent Typical Section Through Percolation Trench . Scale 1:25 Ground Level Topsoil min depth 300mm Base Of Trail Hole 2.10m Upvc distribution pipes used ill be smooth walled, have a 100m O, have 8mm perforations drilled in them 75mm apart and each pipe should be parallel and 2500mm apart. With all pipes joined in a continuous manner All works shall be overseen by a suitable accredited person All Percolation Pipes to be connected separately from the Distribution Box 20 0 0 25 0 0 50 0 10 0 Ve n t P i p e s Important Notes LONGITUDINAL SECTION PLAN VIEW Aaron Mc Bennett Corvoy Ballybay Co Monaghan Email-aaronmcbennett83@gmail.com Mobile- 0870697709 Client - Peter Holland Address Carrivetragh, Clones, Co Monaghan Percolation Design Scale 1:110 Scale 1:40 REC E I V E D : 1 6 / 0 9 / 2 0 2 6 Peter Holland Cavan Clones Monaghan REC E I V E D : 1 6 / 0 9 / 2 0 2 6 Tel: 046 9431389 | VAT: IE 6401624D | Company Reg. 381624 sales@oreillyoakstown.com | www.oreillyoakstown.com O’Reilly Oakstown | Oakstown, Trim, Co.Meath, C15 X499 Date: 9th September 2026 Applicant Name: Peter Holland Site Address: Cavan, Clones, Monaghan Design Capacity: Maximum number of residents: 06 No. of bedrooms: 04 A representative of O’Reilly Oakstown Ltd has assessed the Soil Test Report and confirms the suitability of their Oakstown BAF 8 PE Wastewater Treatment System to treat eAluent being discharged from the above proposed dwelling based on the residential demands submitted to us above. 1. Waste Water Treatment System Design Details: Maximum Capacity Design Loadings: Max no. of users Flow litres/day/person Total hydraulic load B0D5 (grams/day/person) Total organic loading (grams/day) 8 150 1200 litres 60 480 Maximum Daily Design Loadings as per client: Total Organic Loading 0.36kg BOD/day Total Hydraulic loading 0.90m³ /day Average treated eAluent standard – see performance results on EN-12566-3 certification attached BOD 8mg/litre TSS 12mg/litre Ammonia 13mg/litre Proposed System Details – Oakstown BAF 8 P.E. Volume of Total Plant 8m³ Volume of Primary Sedimentation Chambers 4m³ Volume of Secondary Aeration Chamber 2m³ Volume of Biomedia 1.0m³ REC E I V E D : 1 6 / 0 9 / 2 0 2 6 Tel: 046 9431389 | VAT: IE 6401624D | Company Reg. 381624 sales@oreillyoakstown.com | www.oreillyoakstown.com O’Reilly Oakstown | Oakstown, Trim, Co.Meath, C15 X499 2. Wastewater Treatment System Description The Oakstown BAF 8 PE is designed to provide proven, cost eAective primary and secondary wastewater treatment in robust steel reinforced concrete tanks. The primary sedimentation chamber has substantial capacity (4m3) to allow anaerobic digestion to occur naturally while letting sludge settle on the tank floor. Once primary treatment has taken place the eAluent is further degraded in the aeration chamber where oxygen enriched wastewater provides ideal conditions for aerobic bacteria to thrive. Before pumping to the percolation area the clear water is left to further settle in the clarifier chamber to eliminate any remaining settle able solids. 3. Guarantee and Warrantees O’Reilly Oakstown provide a 24 month warranty on all parts. 4. Percolation The percolation area designed must conform to the requirements of Chapters 8 & 10 of EPA Code of Practice 2021 Wastewater Treatment and Disposal System serving single houses. The percolation area requirements are as follows: Groundwater Protection Response: R1 T-value (Subsurface): 24.97 as per Site Characterisation Form. P-value (Surface): 15.14 as per Site Characterisation Form. Depth from ground surface to water table: None Encountered BGL. Depth from ground surface to bed rock: None Encountered BGL. Depth from ground surface to mottling: 1.7m BGL. Area of soil polishing filter: 80m² (10 x 8m linear trenches). Soil Polishing Filter must be covered in 12-32mm washed gravel or broken stone aggregate. Soil Polishing Filter must be covered in geo-textile cover then in topsoil. - See Site Characterisation report for percolation area details. REC E I V E D : 1 6 / 0 9 / 2 0 2 6 Tel: 046 9431389 | VAT: IE 6401624D | Company Reg. 381624 sales@oreillyoakstown.com | www.oreillyoakstown.com O’Reilly Oakstown | Oakstown, Trim, Co.Meath, C15 X499 5. Client Responsibilities unless included in our quotation  Excavation and backfill.  Construction of the percolation / polishing filter as recommended by the site engineer on the Site Characterisation report and/or drawing.  Provision of access for delivery by hi-ab truck to within 3 metres of the excavation.  Provision of a power ducting from the tanks to the house/garage.  Mounting and connection of control panel to mains power in the house/garage. 6. Operation and Maintenance The client is responsible for the operation and maintenance of the wastewater treatment system in accordance with the owner’s manual supplied by O’Reilly Oakstown. Please do not hesitate to contact us if there are any further queries. Yours sincerely Hannah Gibney REC E I V E D : 1 6 / 0 9 / 2 0 2 6 REC E I V E D : 1 6 / 0 9 / 2 0 2 6 REC E I V E D : 1 6 / 0 9 / 2 0 2 6 REC E I V E D : 1 6 / 0 9 / 2 0 2 6 REC E I V E D : 1 6 / 0 9 / 2 0 2 6 REC E I V E D : 1 6 / 0 9 / 2 0 2 6 REC E I V E D : 1 6 / 0 9 / 2 0 2 6 REC E I V E D : 1 6 / 0 9 / 2 0 2 6 REC E I V E D : 1 6 / 0 9 / 2 0 2 6 WWTS LAYOUT - OPTION B WWTS LAYOUT - OPTION A DATE: CHECKED:T0M LYNAM PROJECT:SR-66 O'Reilly Oakstown REV:DWG NO:SCALE: N.T.S. TITLE:8PE BAF SYSTEM DRAWN:VISHWANATH O' REILLY OAKSTOWN LTD. BAF - WASTEWATER TREATMENT SYSTEMS SR66 11/01/2022 I.S. EN ISO 9002 O'REILLY OAKSTOWN TRIM, Co.MEATH Email: info@oreillyoakstown.com Tel:(046)9431389 Fax:(046)9437054 OAKS 201702 AA OAKSTOWN 8PE BAF SYSTEM - SECTIONAL ELEVATION A-A OUTLET TO PERCOLATION AREA AIR COMPRESSOR EXCESS BIOLOGICAL SLUDGE REMOVAL OUTLET TO PERCOLATION AREA OUTLET TO PERCOLATION AREA INLET INLET AIR COMPRESSOR AIR COMPRESSOR INLET VOLUME LITRES:8000 WEIGHT: TANK 1:5500kg TANK 2:6500kg TWO CHAMBER PRIMARY HOLDING TANK THREE CHAMBER BAF UNIT BIOREACTOR CL A R I F I E R PUMP STATION BIOREACTOR CL A R I F I E R PUMP STATION TWO CHAMBER PRIMARY HOLDING TANK THREE CHAMBER BAF UNIT ACCESS COVER 940X780 ACCESS COVER 350X350 ACCESS COVER 350X350 ACCESS COVER 350X350 INLET END SECTION-INLET SIDE REC E I V E D : 1 6 / 0 9 / 2 0 2 6