HomeMy WebLinkAbout2560416 - F.I. Maps - Site layout planST O R M No r t h SITE LAYOUT PLAN PROPOSED - SCALE 1:250 @ A1, 1:500 @ A3 Area 0.581 H RO O F RO O F 99.81 99.80 99.85 99.85 99.83 99.80 99.95 100.00 STORM STORMSTORMSTORM SW - MH 03 SW - MH 04 SW - MH 05 ST O R M ST O R M STO R M STO R M STO R M STO R M STO R M STORM STORM STORM STORM STORM STORM STORMSTORMSTORM SW - MH 03 ST O R M ST O R M ST O R M SW - MH 04 FW - MH - 03 FW - MH - 02 FW - MH - 01 FO U L FO U L FO U L FO U L FO U L FO U L FO U L FO U L FO U L FO U L FO U L FO U L FO U L FO U L FO U L FO U L FO U L FO U L FOUL FOUL FOUL FOUL FOUL FW - MH - 04 SW - MH 04 STO R M STO R M STO R M STO R M STO R M STO R M STO R M RG RG LANDSCAPING LEGEND Existing mature boundary, Native trees and hedging LEGEND Land In Clients / Family Ownership Site Boundary Proposed Levels Existing Levels Existing Foul Drain 122.94 122.25 Right of Way Existing Gravel Surface FOUL Existing Storm Drain STORM Existing Hard Surface Proposed New Buildings / Structures Existing Building Existing Pea Gravel Footpath NOTE: Site dimensions and boundaries are for planning purposes only and as such are not to be used as evidence of title. Proposed new structure covering existing open tanks. Existing underground tanks. Existing carparking area. Existing site entrance. Existing office building be retained. Existing shed 14.3 M 17 . 3 6 M 17 . 9 5 M 51 . 2 3 M 51 . 2 3 M 66.19 M 53.89 M 2.2 9 M 33.38 M 26.62 M 64 . 3 5 M 64 . 4 2 M 30. 2 8 M 29. 1 3 M Existing Building to be Retained Approximate location of public site notice. SW - M H 0 3 STORM STORM STORM STORM STORM STORM ST O R M ST O R M ST O R M STORM STORM STORM STORM SW - MH 0 4 SW - MH 0 4 Surface water silt separator STORM STORM STORM STORM FOUL FOUL FOUL FOUL FOUL FOUL FW - MH - 03 6m x 2.4m Steel Container (Retention 1). 6m x 2.4m Steel Container (Retention 2). Existing Storage Containers. Odder Scrubber System . 5.5 M Proposed New Biofilter Unit. Lorry & Tractor Parking Existing Gravel Footpath Existing Stone Yard Existing Entrance To John Conlons Private House Only. John Conlons Private House . RIAIC M D ARCHITECTS REVISIONJOB NUMBER SCALE CHECKED DWG NUMBER DRAWING JOB CLIENT DWG. SERIES Registered Architect PSDP Accreditation 2025 P info@cmdarchitects.ie042 9743754t e042 9743755t CMD Architects Limited,Thornford Lodge, Broomfield, Castleblayney, Co.Monaghan DrnDate DescriptionRev DATE DRN Do not scale from this drawing. Use figured dimensions in all cases. Verify dimensions on site and report any discrepancies to the architects immediately. This drawing to be read in conjunction with the architects specification. This drawing is copyright and may only be reproduced with the architects permission. ADDITIONAL INFO Mullinary Environmental Services Ltd Change of use of existing machinery shed to proposed waste processing building, erect new Bio Filter Structure to side of building, Retain Ex.storage shed and offiice buildings Site Layout Plan 1:250 @ A1, 1:500 @ A3 O.C. 21-146 3.2FI_002.00 03-10-2025 F.I 20.08.2026 CMD REVISED AS PER REQUEST OF ADDITIONAL INFORMATION REC E I V E D : 1 6 / 0 9 / 2 0 2 6